	fix issue 1115: Don't run rspconfig after hardware discovery finished for servers Other than S822L(TLT)
This commit is contained in:
		| @@ -141,6 +141,11 @@ if [ "$IsStatic" ]; then | ||||
|     fi | ||||
| fi | ||||
|  | ||||
| # Check whether the hardware support in-band BMC configuration with the IPMI device | ||||
| if [ -r /dev/ipmi0 -o -r /dev/ipmi/0 -o -r /dev/ipmidev/0 ]; then | ||||
|     echo "<bmcinband>1</bmcinband>" >> /tmp/discopacket | ||||
| fi | ||||
|  | ||||
| #so we have some cases where DMI table explictly records every function number, and some where only first function is enumerated | ||||
| #so for each onboard device, we record it.  If it is also the first function, we'll seek out other function numbers and append | ||||
| #if that other function number does not show up in its own dmi type 41 record | ||||
|   | ||||
| @@ -371,8 +371,16 @@ sub process_request { | ||||
|         $callback->({error=> ["The node [$node] should have a correct IP address which belongs to the management network."], errorcode=>["1"]}); | ||||
|         return; | ||||
|     } | ||||
|     if ($request->{arch}->[0] =~ /ppc/ and $request->{platform}->[0] =~ /PowerNV/) { | ||||
|         # This is a slow thing to do, and frequently breaks things thoroughly | ||||
|     if (defined($request->{bmcinband})) { | ||||
|         syslog("local4|info", "The attribute bmcinband is specified, just remove the temp BMC node if there is"); | ||||
|         if (defined($request->{pbmc_node}) and defined($request->{pbmc_node}->[0]))  { | ||||
|             my $bmc_node = $request->{pbmc_node}->[0]; | ||||
|             syslog("local4|info", "Find BMC $bmc_node, so remove it"); | ||||
|             $doreq->({ command => ['rmdef'], arg => [$bmc_node]}); | ||||
|         } | ||||
|     } else { | ||||
|         # Only BMC that doesn't support in-band configuration need to run rspconfig out-of-band, such as S822L running in OPAL model | ||||
|         syslog("local4|info", "No bmcinband specified, need to configure BMC out-of-band"); | ||||
|         xCAT::Utils->cleanup_for_powerLE_hardware_discovery($request, $doreq); | ||||
|     } | ||||
|  | ||||
|   | ||||
		Reference in New Issue
	