2
0
mirror of https://github.com/xcat2/xcat-core.git synced 2025-05-29 17:23:08 +00:00

Sync up the spelling to use: OpenPOWER and OpenBMC

This commit is contained in:
Victor Hu 2017-06-02 15:02:02 -04:00
parent 5416a7546e
commit bf382dcd10
13 changed files with 31 additions and 31 deletions

View File

@ -1,10 +1,10 @@
OpenPower Nodes
OpenPOWER Nodes
===============
When compute nodes are physically replaced in the frame, leverage xCAT to re-discover the compute nodes. The following guide can be used for:
* IBM OpenPower S822LC for HPC
* IBM OpenPOWER S822LC for HPC
#. Identify the machine(s) to be replaced: ``frame10cn02``.

View File

@ -1,11 +1,11 @@
IBM Power LE / OpenPOWER
IBM POWER LE / OpenPOWER
=========================
Most of the content is general information for xCAT, the focus and examples are for management of IBM OpenPower servers.
Most of the content is general information for xCAT, the focus and examples are for management of IBM OpenPOWER servers.
IBM OpenPower Servers
* based on Power8 Processor Technology is IPMI managed
* based on Power9 Processor Technology is OpenBmc managed [**Alpha**]
IBM OpenPOWER Servers
* based on POWER8 Processor Technology is IPMI managed
* based on POWER9 Processor Technology is OpenBMC managed [**Alpha**]
.. toctree::

View File

@ -7,11 +7,11 @@ Most enterprise servers do not have video adapters installed with the machine an
Configure the correct console management by modifying the node definition:
* For OpenPower, **IPMI** managed server: ::
* For OpenPOWER, **IPMI** managed server: ::
chdef -t node -o <noderange> cons=ipmi
* For OpenPower, **OpenBMC** managed servers: ::
* For OpenPOWER, **OpenBMC** managed servers: ::
chdef -t node -o <noderange> cons=openbmc

View File

@ -32,7 +32,7 @@ BMC (using IPMI):
\ **rpower**\ \ *noderange*\ [\ **pduon | pduoff | pdustat | pdureset**\ ]
OpenPower BMC (using IPMI):
OpenPOWER BMC (using IPMI):
===========================
@ -41,7 +41,7 @@ OpenPower BMC (using IPMI):
\ **rpower**\ \ *noderange*\ [\ **pduon | pduoff | pdustat | pdureset**\ ]
OpenPower OpenBMC:
OpenPOWER OpenBMC:
==================

View File

@ -27,7 +27,7 @@ DESCRIPTION
***********
Setting for nodes that are controlled by an on-board OpenBmc.
Setting for nodes that are controlled by an on-board OpenBMC.
*******************

View File

@ -567,7 +567,7 @@ notification(5)|notification.5
openbmc(5)|openbmc.5
Setting for nodes that are controlled by an on-board OpenBmc.
Setting for nodes that are controlled by an on-board OpenBMC.

View File

@ -71,7 +71,7 @@ xCAT 2.12.x
| | | | |
+---------------------------------+---------------+-------------+----------------------------------+
|| xCAT 2.12.3 | | |- GitHub Issues resolved |
|| 2016/09/30 | | |- rinv options for OpenPower |
|| 2016/09/30 | | |- rinv options for OpenPOWER |
|| | | |- switch based switch discovery |
| `2.12.3 Release Notes <https:// | | |- additional options added to |
| github.com/xcat2/xcat-core/wiki | | | xcatprobe command |
@ -124,7 +124,7 @@ xCAT 2.11.x
|| 2015/12/11 |- UBT 14.4.3 LE|- S822LC(GTA)|- Infiniband for OpenPOWER |
|| |- UBT 15.10 LE |- S812LC |- SW KIT support for OpenPOWER |
| `2.11 Release Notes <https:// |- PowerKVM 3.1 |- NeuCloud OP|- renergy command for OpenPOWER |
| github.com/xcat2/xcat-core/ | |- ZoomNet RP |- rflash command for OpenPower |
| github.com/xcat2/xcat-core/ | |- ZoomNet RP |- rflash command for OpenPOWER |
| wiki/XCAT_2.11_Release_Notes>`_ | | |- Add xCAT Troubleshooting Log |
| | | |- xCAT Log Classification |
| | | |- RAID Configuration |

View File

@ -1365,7 +1365,7 @@ sub gen_chain_for_profiles {
#run bmcsetups.
#PowerNV nodes can't use 'runcmd=bmcsetup' to set BMC.
#But OpenPower need to support bmcsetup
#But OpenPOWER need to support bmcsetup
my $nodehmtab = xCAT::Table->new('nodehm');
my $comments = "";
my $nodehmtab_entry = $nodehmtab->getNodeAttribs($hwprofile, ['comments']);

View File

@ -446,7 +446,7 @@ passed as argument rather than by table value',
openbmc => {
cols => [qw(node bmc consport taggedvlan username password comments disable)],
keys => [qw(node)],
table_desc => 'Setting for nodes that are controlled by an on-board OpenBmc.',
table_desc => 'Setting for nodes that are controlled by an on-board OpenBMC.',
descriptions => {
node => 'The node name or group name.',
bmc => 'The hostname of the BMC adapter.',

View File

@ -29,10 +29,10 @@ my %usage = (
BMC (using IPMI):
rpower noderange [on|off|softoff|reset|boot|stat|state|status|wake|suspend [-w timeout] [-o] [-r]]
rpower noderange [pduon|pduoff|pdustat]
OpenPower BMC:
OpenPOWER BMC:
rpower noderange [on|off|reset|boot|stat|state|status]
rpower noderange [pduon|pduoff|pdustat]
OpenPower OpenBMC:
OpenPOWER OpenBMC:
rpower noderange [on|off|reset|boot|stat|state|status]
KVM Virtualization specific:
rpower <noderange> [boot] [ -c <path to iso> ]

View File

@ -14,13 +14,13 @@ B<rpower> I<noderange> [B<on>|B<off>|B<softoff>|B<reset>|B<boot>|B<stat>|B<state
B<rpower> I<noderange> [B<pduon>|B<pduoff>|B<pdustat>|B<pdureset>]
=head2 OpenPower BMC (using IPMI):
=head2 OpenPOWER BMC (using IPMI):
B<rpower> I<noderange> [B<on>|B<off>|B<reset>|B<boot>|B<stat>|B<state>|B<status>]
B<rpower> I<noderange> [B<pduon>|B<pduoff>|B<pdustat>|B<pdureset>]
=head2 OpenPower OpenBMC:
=head2 OpenPOWER OpenBMC:
B<rpower> I<noderange> [B<off>|B<on>|B<reset>|B<boot>|B<stat>|B<state>|B<status>]

View File

@ -37,7 +37,7 @@ function cold_reset_bmc() {
fi
if [ "$XPROD" = "309" -o "$XPROD" = "43707" ] ; then
if [ "$XPROD" = "43707" ]; then
# OpenPower SPECIFIC, the OpenPower machines with AMI BMC should NOT need a
# OpenPOWER SPECIFIC, the OpenPOWER machines with AMI BMC should NOT need a
# reset after applying ipmitool commands. However, it seems there is a problem with
# the BMC where after 15 seconds, it stops responding. To work around, sleep 30
# seconds before issuing the reset of the BMC.
@ -49,7 +49,7 @@ function cold_reset_bmc() {
fi
if [ "$XPROD" = "43707" ]; then
# OpenPower SPECIFIC, check the BMC with the following raw command to
# OpenPOWER SPECIFIC, check the BMC with the following raw command to
# make sure that the bmc is really in a "ready" state before continuing
SLEEP_INTERVAL=3
MAX_ITERATION=100
@ -65,7 +65,7 @@ function cold_reset_bmc() {
TOTAL_SEC=$((${SLEEP_INTERVAL} * ${MAX_ITERATION}))
logger -s -t $log_label -p local4.error "ERROR, After waiting ${TOTAL_SEC} seconds, the BMC is not in a ready state."
else
# for Non OpenPower servers, just sleep for some set time.
# for Non OpenPOWER servers, just sleep for some set time.
sleep 15
TRIES=0
@ -82,7 +82,7 @@ function cold_reset_bmc() {
#
# Function snooze()
#
# The purpose of this is to work around the issue with OpenPower BMCs after
# The purpose of this is to work around the issue with OpenPOWER BMCs after
# making a change to network configuration, sleep 30 to be sure the changes apply.
#
function snooze() {
@ -95,8 +95,8 @@ function snooze() {
return
fi
if [ "$XPROD" = "43707" ]; then
# For OpenPower Machines
logger -s -t $log_label -p local4.debug "OpenPower, snooze for 30 seconds..."
# For OpenPOWER Machines
logger -s -t $log_label -p local4.debug "OpenPOWER, snooze for 30 seconds..."
sleep 30
else
logger -s -t $log_label -p local4.debug "snooze for 1 second..."
@ -167,7 +167,7 @@ logger -s -t $log_label -p local4.info "IPMIVER=$IPMIVER, IPMIMFG=$IPMIMFG, XPRO
#
# IPMIMFG=2 = IBM
# IPMIMFG=0 = OpenPower
# IPMIMFG=0 = OpenPOWER
# IPMIMFG=42817 and XPROD=16975 = OpenBMC
#
if [ "$IPMIMFG" == 2 ]; then #IBM
@ -416,7 +416,7 @@ if [ ! -z "$ISOPENBMC" ]; then
rm -f /tmp/ipmicfg.xml
exit $bmc_config_rc
fi
# After network commands are issued, pause to allow the BMC to apply (OpenPower)
# After network commands are issued, pause to allow the BMC to apply (OpenPOWER)
snooze
let idev=NUMBMCS-1
@ -646,7 +646,7 @@ while [ $idev -gt 0 ]; do
logger -s -t $log_label -p local4.info "Lighting Identify Light"
if [ "$XPROD" = "43707" -a "$IPMIMFG" = '0' ]; then
# OpenPower BMC specific, turn on the LED beacon light.
# OpenPOWER BMC specific, turn on the LED beacon light.
# - default interval, # ipmitool chassis identify
# Chassis identify interval: default (15 seconds)
# - 275 is too large, # ipmitool chassis identify 275

View File

@ -2535,7 +2535,7 @@ sub power {
my $code;
if (($sessdata->{subcommand} !~ /^on$|^off$|^reset$|^boot$|^stat$|^state$|^status$/) and isopenpower($sessdata)) {
xCAT::SvrUtils::sendmsg([ 1, "unsupported command rpower $sessdata->{subcommand} for OpenPower" ], $callback, $sessdata->{node}, %allerrornodes);
xCAT::SvrUtils::sendmsg([ 1, "unsupported command rpower $sessdata->{subcommand} for OpenPOWER" ], $callback, $sessdata->{node}, %allerrornodes);
return;
}