Schema.pm: add documentation for multi-value ipmi.bmcport for Dell
servers
This commit is contained in:
@@ -430,6 +430,15 @@ passed as argument rather than by table value',
|
||||
2 2 Third interface on ML2 or mezzanine adapter
|
||||
2 3 Fourth interface on ML2 or mezzanine adapter
|
||||
|
||||
For Dell systems, a second and third values can also be used:
|
||||
1st value: 0 = shared / 1 = dedicated
|
||||
2nd value shared LOM (1-4) (0 or no value means first available LOM)
|
||||
3rd value: failover LOM (1-4) (0 means no failover, no value means all LOMs)
|
||||
0 Shared with first available interface, failover all LOMs (catch all mode)
|
||||
0 1 Shared with LOM1, failover all LOMs
|
||||
0 1 2 Shared with LOM1, failover LOM2
|
||||
0 2 0 Shared with LOM2, no failover
|
||||
1 Dedicated',
|
||||
taggedvlan => 'bmcsetup script will configure the network interface of the BMC to be tagged to the VLAN specified.',
|
||||
bmcid => 'Unique identified data used by discovery processes to distinguish known BMCs from unrecognized BMCs',
|
||||
username => 'The BMC userid. If not specified, the key=ipmi row in the passwd table is used as the default.',
|
||||
|