Extend FPC status

FPC PSU status reporting requires OEM commands. Provide
OEM to pyghmi sensor model translation. to enable normal
applications to read it.

Change-Id: I63b950db7ffa5a5a2ba2ed3a2f2be33a53221b03
This commit is contained in:
Jarrod Johnson
2016-10-04 10:18:20 -04:00
parent e52c0e3405
commit aee3ae36b0

View File

@@ -49,6 +49,29 @@ def fpc_read_psu_fan(ipmicmd, number):
return struct.unpack_from('<H', rsp[:2])[0]
def fpc_get_psustatus(ipmicmd, number):
rsp = ipmicmd.xraw_command(netfn=0x32, command=0x91)
mask = 1 << (number - 1)
statdata = bytearray(rsp['data'])
presence = statdata[3] & mask == mask
pwrgood = statdata[4] & mask == mask
throttle = (statdata[6] | statdata[2]) & mask == mask
health = pygconst.Health.Ok
states = []
if presence and not pwrgood:
health = pygconst.Health.Critical
states.append('Power input lost')
if throttle:
health = pygconst.Health.Critical
states.append('Throttled')
if presence:
states.append('Present')
else:
states.append('Absent')
health = pygconst.Health.Critical
return (health, states)
def fpc_get_nodeperm(ipmicmd, number):
rsp = ipmicmd.xraw_command(netfn=0x32, command=0xa7, data=(number,))
perminfo = ord(rsp['data'][1])
@@ -97,11 +120,18 @@ fpc_sensors = {
},
'Node Power Permission': {
'type': 'Management Subsystem Health',
'returns': 'dict',
'returns': 'tuple',
'units': None,
'provider': fpc_get_nodeperm,
'elements': 12,
},
'Power Supply': {
'type': 'Power Supply',
'returns': 'tuple',
'units': None,
'provider': fpc_get_psustatus,
'elements': 6,
}
}