B<renergy> - remote energy management tool
=head1 B<SYNOPSIS>
B<renergy> [-h | --help]
B<renergy> [-v | --version]
B<Power 6 server specific :>
=over 2
B<renergy> I<noderange> [-V] { all | { [savingstatus] [cappingstatus]
B<renergy> I<noderange> [-V] { all | [savingstatus] [cappingstatus]
[cappingmaxmin] [cappingvalue] [cappingsoftmin] [averageAC]
[averageDC] [ambienttemp] [exhausttemp] [CPUspeed] } }
[averageDC] [ambienttemp] [exhausttemp] [CPUspeed] }
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
| {cappingstatus}={on | off} | {cappingwatt}=watt
| {cappingperc}=percentage }
B<renergy> I<noderange> [-V] { savingstatus={on | off}
| cappingstatus={on | off} | cappingwatt=watt
| cappingperc=percentage }
=back
@ -28,66 +26,78 @@ B<Power 7 server specific :>
=over 2
B<renergy> I<noderange> [-V] { all | { [savingstatus] [dsavingstatus]
B<renergy> I<noderange> [-V] { all | [savingstatus] [dsavingstatus]
[cappingstatus] [cappingmaxmin] [cappingvalue] [cappingsoftmin]
[averageAC] [averageDC] [ambienttemp] [exhausttemp] [CPUspeed]
[syssbpower] [sysIPLtime] } }
[syssbpower] [sysIPLtime] }
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
| {dsavingstatus}={on-norm | on-maxp | off}
| {cappingstatus}={on | off} | {cappingwatt}=watt
| {cappingperc}=percentage }
B<renergy> I<noderange> [-V] { savingstatus={on | off}
| dsavingstatus={on-norm | on-maxp | off}
| cappingstatus={on | off} | cappingwatt=watt
| cappingperc=percentage }
=back
B<Blade specific :>
B<BladeCenter specific :>
=over 2
B<For node of blade management module:>
B<For Management Modules as the target:>
=over 4
B<renergy> I<noderange> [-V] { all | pd1all | pd2all | { [pd1status]
B<renergy> I<noderange> [-V] { all | pd1all | pd2all | [pd1status]
[pd2status] [pd1policy] [pd2policy] [pd1powermodule1]
[pd1powermodule2] [pd2powermodule1] [pd2powermodule2]
[pd1avaiablepower] [pd2avaiablepower] [pd1reservedpower]
[pd2reservedpower] [pd1remainpower] [pd2remainpower]
[pd1inusedpower] [pd2inusedpower] [availableDC] [averageAC]
[thermaloutput] [ambienttemp] [mmtemp] } }
[thermaloutput] [ambienttemp] [mmtemp] }
=back
B<For node of blade server:>
B<For a blades as the target:>
=over 4
B<renergy> I<noderange> [-V] { all | { [averageDC]
B<renergy> I<noderange> [-V] { all | [averageDC]
[capability] [cappingvalue] [CPUspeed] [maxCPUspeed]
[savingstatus] [dsavingstatus] } }
[savingstatus] [dsavingstatus] }
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
| {dsavingstatus}={on-norm | on-maxp | off} }
B<renergy> I<noderange> [-V] { savingstatus={on | off}
| dsavingstatus={on-norm | on-maxp | off} }
=back
=back
B<iDataPlex specific :>
=over 2
B<renergy> I<noderange> [-V] [ { cappingmaxmin | cappingmax | cappingmin } ]
[cappingstatus] [cappingvalue] [relhistogram]
B<renergy> I<noderange> [-V] { cappingstatus={on | enable | off | disable}
| {cappingwatt|cappingvalue}=watt }
=back
=head1 B<DESCRIPTION>
This B<renergy> command can be used to manage the energy consumption of
IBM servers which support IBM EnergyScale technology. Through this command,
user can query and set the power saving and power capping status, also can
user can query and set the power saving and power capping status, and also can
query the average consumed energy, the ambient and exhaust temperature,
the processor frequency for a server.
B<renergy> command supports IBM POWER6 and POWER7 rack-mounted servers
(system P CEC node), blade management module node, blade server node.
For rack-mounted servers, following specific hardware types are supported:
B<renergy> command supports IBM POWER6 and POWER7 rack-mounted servers,
BladeCenter management modules, blade servers, and iDataPlex servers.
For system p rack-mounted servers, the following specific hardware types are supported:
I<8203-E4A>, I<8204-E8A>, I<9125-F2A>, I<8233-E8B>, I<8236-E8C>.
The parameter I<noderange> needs to be specified for B<renergy> command to
get the target server. The I<noderange> should be a list of CEC node names, blade
The parameter I<noderange> needs to be specified for the B<renergy> command to
get the target servers. The I<noderange> should be a list of CEC node names, blade
management module node names or blade server node names. Lpar name
is not acceptable here.
@ -98,10 +108,10 @@ gets and displays the current value. Otherwise, if specifying the attribute with
The attributes listed in the B<SYNOPSIS> section are which ones can be handled by
B<renergy> command. But for each specific type of server, there are some attributes that
are not supported. If user specifies an attribute which does not be supported by certain
are not supported. If user specifies an attribute which is not supported by a specific
server, the return value of this attribute will be 'na'.
The supported attributes for each specific hardware types are listed as follow:
The supported attributes for each specific system p hardware type is listed as follows:
=over 2
@ -154,17 +164,19 @@ For system P CEC nodes, each query operation for attribute CPUspeed, averageAC
or averageDC needs about 30 seconds to complete. The query for others attributes
will get response immediately.
=head1 B<PREREQUISITES>
=head1 B<PREREQUISITE>
For the system P CEC nodes, B<renergy> command depends
on the Energy Management Plugin for xCAT B<xCAT-cimclient> to
communicate with server. Then, before running the B<renergy> command, to
check whether the B<xCAT-cimclient> package has been installed.
B<xCAT-cimclient> can be downloaded from IBM web site:
For the system p nodes, the B<renergy> command depends
on the Energy Management Plugin B<xCAT-energy> to
communicate with server. B<xCAT-energy> can be downloaded from the IBM web site:
http://www14.software.ibm.com/webapp/set2/sas/f/xcat/energy.html
For iDataPlex nodes, the B<renergy> command depends
on the Energy Management Plugin B<perl-IBM-EnergyManager> to
communicate with server. This plugin must be requested from IBM.
(The support for BladeCenter energy management is built into base xCAT,
so no additional plugins are needed for BladeCenter.)
=head1 B<OPTIONS>
@ -394,6 +406,10 @@ Query the remaining power available in power domain 2.
Query the total power being used in power domain 2.
=item B<relhistogram>
Query histogram data for wattage information
=item B<savingstatus>
Query the static power saving status. The result should be
@ -429,14 +445,12 @@ center chassis.
=back
=head1 B<RETURN VALUE>
0 The command completed successfully.
1 An error has occurred.
=head1 B<EXAMPLES>
=over 3
@ -571,7 +585,7 @@ The output of the setting operation:
=item 1
The more information of 'Power System Energy Management':
For more information on 'Power System Energy Management':
http://www-03.ibm.com/systems/power/software/energy/index.html