| Generic Thermal Sysfs driver How To
 | |
| ===================================
 | |
| 
 | |
| Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
 | |
| 
 | |
| Updated: 2 January 2008
 | |
| 
 | |
| Copyright (c)  2008 Intel Corporation
 | |
| 
 | |
| 
 | |
| 0. Introduction
 | |
| 
 | |
| The generic thermal sysfs provides a set of interfaces for thermal zone
 | |
| devices (sensors) and thermal cooling devices (fan, processor...) to register
 | |
| with the thermal management solution and to be a part of it.
 | |
| 
 | |
| This how-to focuses on enabling new thermal zone and cooling devices to
 | |
| participate in thermal management.
 | |
| This solution is platform independent and any type of thermal zone devices
 | |
| and cooling devices should be able to make use of the infrastructure.
 | |
| 
 | |
| The main task of the thermal sysfs driver is to expose thermal zone attributes
 | |
| as well as cooling device attributes to the user space.
 | |
| An intelligent thermal management application can make decisions based on
 | |
| inputs from thermal zone attributes (the current temperature and trip point
 | |
| temperature) and throttle appropriate devices.
 | |
| 
 | |
| [0-*]	denotes any positive number starting from 0
 | |
| [1-*]	denotes any positive number starting from 1
 | |
| 
 | |
| 1. thermal sysfs driver interface functions
 | |
| 
 | |
| 1.1 thermal zone device interface
 | |
| 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
 | |
| 		int trips, void *devdata, struct thermal_zone_device_ops *ops)
 | |
| 
 | |
|     This interface function adds a new thermal zone device (sensor) to
 | |
|     /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
 | |
|     thermal cooling devices registered at the same time.
 | |
| 
 | |
|     name: the thermal zone name.
 | |
|     trips: the total number of trip points this thermal zone supports.
 | |
|     devdata: device private data
 | |
|     ops: thermal zone device call-backs.
 | |
| 	.bind: bind the thermal zone device with a thermal cooling device.
 | |
| 	.unbind: unbind the thermal zone device with a thermal cooling device.
 | |
| 	.get_temp: get the current temperature of the thermal zone.
 | |
| 	.get_mode: get the current mode (user/kernel) of the thermal zone.
 | |
| 	    - "kernel" means thermal management is done in kernel.
 | |
| 	    - "user" will prevent kernel thermal driver actions upon trip points
 | |
| 	      so that user applications can take charge of thermal management.
 | |
| 	.set_mode: set the mode (user/kernel) of the thermal zone.
 | |
| 	.get_trip_type: get the type of certain trip point.
 | |
| 	.get_trip_temp: get the temperature above which the certain trip point
 | |
| 			will be fired.
 | |
| 
 | |
| 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
 | |
| 
 | |
|     This interface function removes the thermal zone device.
 | |
|     It deletes the corresponding entry form /sys/class/thermal folder and
 | |
|     unbind all the thermal cooling devices it uses.
 | |
| 
 | |
| 1.2 thermal cooling device interface
 | |
| 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
 | |
| 		void *devdata, struct thermal_cooling_device_ops *)
 | |
| 
 | |
|     This interface function adds a new thermal cooling device (fan/processor/...)
 | |
|     to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
 | |
|     to all the thermal zone devices register at the same time.
 | |
|     name: the cooling device name.
 | |
|     devdata: device private data.
 | |
|     ops: thermal cooling devices call-backs.
 | |
| 	.get_max_state: get the Maximum throttle state of the cooling device.
 | |
| 	.get_cur_state: get the Current throttle state of the cooling device.
 | |
| 	.set_cur_state: set the Current throttle state of the cooling device.
 | |
| 
 | |
| 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
 | |
| 
 | |
|     This interface function remove the thermal cooling device.
 | |
|     It deletes the corresponding entry form /sys/class/thermal folder and
 | |
|     unbind itself from all the thermal zone devices using it.
 | |
| 
 | |
| 1.3 interface for binding a thermal zone device with a thermal cooling device
 | |
| 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
 | |
| 		int trip, struct thermal_cooling_device *cdev);
 | |
| 
 | |
|     This interface function bind a thermal cooling device to the certain trip
 | |
|     point of a thermal zone device.
 | |
|     This function is usually called in the thermal zone device .bind callback.
 | |
|     tz: the thermal zone device
 | |
|     cdev: thermal cooling device
 | |
|     trip: indicates which trip point the cooling devices is associated with
 | |
| 	  in this thermal zone.
 | |
| 
 | |
| 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
 | |
| 		int trip, struct thermal_cooling_device *cdev);
 | |
| 
 | |
|     This interface function unbind a thermal cooling device from the certain
 | |
|     trip point of a thermal zone device. This function is usually called in
 | |
|     the thermal zone device .unbind callback.
 | |
|     tz: the thermal zone device
 | |
|     cdev: thermal cooling device
 | |
|     trip: indicates which trip point the cooling devices is associated with
 | |
| 	  in this thermal zone.
 | |
| 
 | |
| 2. sysfs attributes structure
 | |
| 
 | |
| RO	read only value
 | |
| RW	read/write value
 | |
| 
 | |
| Thermal sysfs attributes will be represented under /sys/class/thermal.
 | |
| Hwmon sysfs I/F extension is also available under /sys/class/hwmon
 | |
| if hwmon is compiled in or built as a module.
 | |
| 
 | |
| Thermal zone device sys I/F, created once it's registered:
 | |
| /sys/class/thermal/thermal_zone[0-*]:
 | |
|     |---type:			Type of the thermal zone
 | |
|     |---temp:			Current temperature
 | |
|     |---mode:			Working mode of the thermal zone
 | |
|     |---trip_point_[0-*]_temp:	Trip point temperature
 | |
|     |---trip_point_[0-*]_type:	Trip point type
 | |
| 
 | |
| Thermal cooling device sys I/F, created once it's registered:
 | |
| /sys/class/thermal/cooling_device[0-*]:
 | |
|     |---type:			Type of the cooling device(processor/fan/...)
 | |
|     |---max_state:		Maximum cooling state of the cooling device
 | |
|     |---cur_state:		Current cooling state of the cooling device
 | |
| 
 | |
| 
 | |
| Then next two dynamic attributes are created/removed in pairs. They represent
 | |
| the relationship between a thermal zone and its associated cooling device.
 | |
| They are created/removed for each successful execution of
 | |
| thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
 | |
| 
 | |
| /sys/class/thermal/thermal_zone[0-*]:
 | |
|     |---cdev[0-*]:		[0-*]th cooling device in current thermal zone
 | |
|     |---cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with
 | |
| 
 | |
| Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
 | |
| the generic thermal driver also creates a hwmon sysfs I/F for each _type_
 | |
| of thermal zone device. E.g. the generic thermal driver registers one hwmon
 | |
| class device and build the associated hwmon sysfs I/F for all the registered
 | |
| ACPI thermal zones.
 | |
| 
 | |
| /sys/class/hwmon/hwmon[0-*]:
 | |
|     |---name:			The type of the thermal zone devices
 | |
|     |---temp[1-*]_input:	The current temperature of thermal zone [1-*]
 | |
|     |---temp[1-*]_critical:	The critical trip point of thermal zone [1-*]
 | |
| 
 | |
| Please read Documentation/hwmon/sysfs-interface for additional information.
 | |
| 
 | |
| ***************************
 | |
| * Thermal zone attributes *
 | |
| ***************************
 | |
| 
 | |
| type
 | |
| 	Strings which represent the thermal zone type.
 | |
| 	This is given by thermal zone driver as part of registration.
 | |
| 	E.g: "acpitz" indicates it's an ACPI thermal device.
 | |
| 	In order to keep it consistent with hwmon sys attribute; this should
 | |
| 	be a short, lowercase string, not containing spaces nor dashes.
 | |
| 	RO, Required
 | |
| 
 | |
| temp
 | |
| 	Current temperature as reported by thermal zone (sensor).
 | |
| 	Unit: millidegree Celsius
 | |
| 	RO, Required
 | |
| 
 | |
| mode
 | |
| 	One of the predefined values in [kernel, user].
 | |
| 	This file gives information about the algorithm that is currently
 | |
| 	managing the thermal zone. It can be either default kernel based
 | |
| 	algorithm or user space application.
 | |
| 	kernel	= Thermal management in kernel thermal zone driver.
 | |
| 	user	= Preventing kernel thermal zone driver actions upon
 | |
| 		  trip points so that user application can take full
 | |
| 		  charge of the thermal management.
 | |
| 	RW, Optional
 | |
| 
 | |
| trip_point_[0-*]_temp
 | |
| 	The temperature above which trip point will be fired.
 | |
| 	Unit: millidegree Celsius
 | |
| 	RO, Optional
 | |
| 
 | |
| trip_point_[0-*]_type
 | |
| 	Strings which indicate the type of the trip point.
 | |
| 	E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
 | |
| 	thermal zone.
 | |
| 	RO, Optional
 | |
| 
 | |
| cdev[0-*]
 | |
| 	Sysfs link to the thermal cooling device node where the sys I/F
 | |
| 	for cooling device throttling control represents.
 | |
| 	RO, Optional
 | |
| 
 | |
| cdev[0-*]_trip_point
 | |
| 	The trip point with which cdev[0-*] is associated in this thermal
 | |
| 	zone; -1 means the cooling device is not associated with any trip
 | |
| 	point.
 | |
| 	RO, Optional
 | |
| 
 | |
| passive
 | |
| 	Attribute is only present for zones in which the passive cooling
 | |
| 	policy is not supported by native thermal driver. Default is zero
 | |
| 	and can be set to a temperature (in millidegrees) to enable a
 | |
| 	passive trip point for the zone. Activation is done by polling with
 | |
| 	an interval of 1 second.
 | |
| 	Unit: millidegrees Celsius
 | |
| 	RW, Optional
 | |
| 
 | |
| *****************************
 | |
| * Cooling device attributes *
 | |
| *****************************
 | |
| 
 | |
| type
 | |
| 	String which represents the type of device, e.g:
 | |
| 	- for generic ACPI: should be "Fan", "Processor" or "LCD"
 | |
| 	- for memory controller device on intel_menlow platform:
 | |
| 	  should be "Memory controller".
 | |
| 	RO, Required
 | |
| 
 | |
| max_state
 | |
| 	The maximum permissible cooling state of this cooling device.
 | |
| 	RO, Required
 | |
| 
 | |
| cur_state
 | |
| 	The current cooling state of this cooling device.
 | |
| 	The value can any integer numbers between 0 and max_state:
 | |
| 	- cur_state == 0 means no cooling
 | |
| 	- cur_state == max_state means the maximum cooling.
 | |
| 	RW, Required
 | |
| 
 | |
| 3. A simple implementation
 | |
| 
 | |
| ACPI thermal zone may support multiple trip points like critical, hot,
 | |
| passive, active. If an ACPI thermal zone supports critical, passive,
 | |
| active[0] and active[1] at the same time, it may register itself as a
 | |
| thermal_zone_device (thermal_zone1) with 4 trip points in all.
 | |
| It has one processor and one fan, which are both registered as
 | |
| thermal_cooling_device.
 | |
| 
 | |
| If the processor is listed in _PSL method, and the fan is listed in _AL0
 | |
| method, the sys I/F structure will be built like this:
 | |
| 
 | |
| /sys/class/thermal:
 | |
| 
 | |
| |thermal_zone1:
 | |
|     |---type:			acpitz
 | |
|     |---temp:			37000
 | |
|     |---mode:			kernel
 | |
|     |---trip_point_0_temp:	100000
 | |
|     |---trip_point_0_type:	critical
 | |
|     |---trip_point_1_temp:	80000
 | |
|     |---trip_point_1_type:	passive
 | |
|     |---trip_point_2_temp:	70000
 | |
|     |---trip_point_2_type:	active0
 | |
|     |---trip_point_3_temp:	60000
 | |
|     |---trip_point_3_type:	active1
 | |
|     |---cdev0:			--->/sys/class/thermal/cooling_device0
 | |
|     |---cdev0_trip_point:	1	/* cdev0 can be used for passive */
 | |
|     |---cdev1:			--->/sys/class/thermal/cooling_device3
 | |
|     |---cdev1_trip_point:	2	/* cdev1 can be used for active[0]*/
 | |
| 
 | |
| |cooling_device0:
 | |
|     |---type:			Processor
 | |
|     |---max_state:		8
 | |
|     |---cur_state:		0
 | |
| 
 | |
| |cooling_device3:
 | |
|     |---type:			Fan
 | |
|     |---max_state:		2
 | |
|     |---cur_state:		0
 | |
| 
 | |
| /sys/class/hwmon:
 | |
| 
 | |
| |hwmon0:
 | |
|     |---name:			acpitz
 | |
|     |---temp1_input:		37000
 | |
|     |---temp1_crit:		100000
 |