| =head1 NAME
 | |
| 
 | |
| B<rscan> - Collects node information from one or more hardware control points.
 | |
| 
 | |
| =head1 SYNOPSIS
 | |
| 
 | |
| B<rscan [-h|--help]>
 | |
| 
 | |
| B<rscan [-v|--version]>
 | |
| 
 | |
| B<rscan [-V|--verbose]> I<noderange>  B<[-u][-w][-x|-z]>
 | |
| 
 | |
| 
 | |
| =head1 DESCRIPTION
 | |
| 
 | |
| The rscan command lists hardware information for each node managed by the hardware control points specified in noderange.
 | |
| 
 | |
| For the management module of blade, if the blade server is a Flex system P node, the fsp belongs to the blade server also will be scanned.
 | |
| 
 | |
| For the KVM host, all the KVM guests on the specified KVM host will be scanned. Note: currently rscan can only get the information of the "disk" device on the kvm guest with the underlying source as a "file" on the KVM host.
 | |
| 
 | |
| Note: The first line of the output always contains information about the hardware control point. When using the rscan command to generate output for HMC or IVM hardware control points, it provides the FSPs and BPAs as part of the output. The only exception is the rscan -u flag which provides updates made hardware control point in the xCAT database. 
 | |
| 
 | |
| =head1 OPTIONS
 | |
| 
 | |
| 
 | |
| 
 | |
| B<-h|--help>          Display usage message.
 | |
| 
 | |
| B<-v|--version>          Command Version.
 | |
| 
 | |
| B<-V|--verbose>          Verbose output.
 | |
| 
 | |
| B<-u>          Updates and then prints out node definitions in the xCAT database for CEC/BPA. It updates the existing nodes that contain the same mtms and serial number for nodes managed by the specified hardware control point. This primarily works with CEC/FSP and frame/BPA nodes when the node name is not the same as the managed system name on hardware control point (HMC), This flag will update the BPA/FSP node name definitions to be listed as the managed system name in the xCAT database.  
 | |
| 
 | |
| For the Flex system manager, both the blade server and fsp object of xCAT will be updated if the mpa and slot id are matched to the object which has been defined in the xCAT database.
 | |
| 
 | |
| For the KVM host, the information of the KVM guests which have been defined in xCAT database will be updated. 
 | |
| 
 | |
| Note: only the matched object will be updated.
 | |
| 
 | |
| B<-n>          For KVM host, the information of the KVM guests, which are not defined in xCAT database yet, will be written into xCAT database.
 | |
| 
 | |
| B<-w>          Writes output to xCAT database.
 | |
| 
 | |
| For KVM host, updates the information of the KVM guests which have been defined in xCAT database with the same node name and KVM host, creates the definition of the KVM guests which do not exist in xCAT database , and notifies user about the conflicting KVM guests that the name exist in xCAT database but the kvm host is different. 
 | |
| 
 | |
| B<-x>          XML format.
 | |
| 
 | |
| B<-z>          Stanza formated output.
 | |
| 
 | |
| 
 | |
| =head1 RETURN VALUE
 | |
| 
 | |
| 0 The command completed successfully.
 | |
| 
 | |
| 1 An error has occurred.
 | |
| 
 | |
| =head1 EXAMPLES
 | |
| 
 | |
| 1. To list all nodes managed by HMC hmc01 in tabular format, enter:
 | |
| 
 | |
|  rscan hmc01
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   type    name                       id   type-model  serial-number  address
 | |
| 
 | |
|   hmc     hmc01                           7310-C05    10F426A        hmc01
 | |
|   fsp     Server-9117-MMA-SN10F6F3D       9117-MMA    10F6F3D        3.3.3.197
 | |
|   lpar    lpar3                       4   9117-MMA    10F6F3D
 | |
|   lpar    lpar2                       3   9117-MMA    10F6F3D
 | |
|   lpar    lpar1                       2   9117-MMA    10F6F3D
 | |
|   lpar    p6vios                      1   9117-MMA    10F6F3D
 | |
| 
 | |
| 
 | |
| 2. To list all nodes managed by IVM ivm02 in XML format and write the output to the xCAT database, enter:
 | |
| 
 | |
|  rscan ivm02 -x -w
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|  <Node>
 | |
|    <cons></cons>
 | |
|    <profile></profile>
 | |
|    <parent></parent>
 | |
|    <serial>10B7D1G</serial>
 | |
|    <model>9133-55A</model>
 | |
|    <node>Server-9133-55A-10B7D1G</node>
 | |
|    <mgt>ivm</mgt>
 | |
|    <nodetype>fsp</nodetype>
 | |
|    <hcp>ivm02</hcp>
 | |
|    <groups>fsp,all</groups>
 | |
|    <id>10</id>
 | |
|  </Node>
 | |
| 
 | |
|  <Node>
 | |
|    <cons>ivm</cons>
 | |
|    <profile>lpar01</profile>
 | |
|    <parent>Server-9133-55A-10B7D1G</parent>
 | |
|    <serial></serial>
 | |
|    <model></model>
 | |
|    <node>lpar01</node>
 | |
|    <mgt>ivm</mgt>
 | |
|    <nodetype>lpar,osi</nodetype>
 | |
|    <hcp>ivm02</hcp>
 | |
|    <groups>lpar,all</groups>
 | |
|    <id>1</id>
 | |
|  <Node>
 | |
| 
 | |
|  </Node>
 | |
|    <cons>ivm</cons>
 | |
|    <profile>lpar02</profile>
 | |
|    <parent>Server-9133-55A-10B7D1G</parent>
 | |
|    <serial></serial>
 | |
|    <model></model>
 | |
|    <node>lpar02</node>
 | |
|    <mgt>ivm</mgt>
 | |
|    <nodetype>lpar,osi</nodetype>
 | |
|    <hcp>ivm02</hcp>
 | |
|    <groups>lpar,all</groups>
 | |
|    <id>2</id>
 | |
|  </Node>
 | |
| 
 | |
| 
 | |
| 3. To list all nodes managed by HMC hmc02 in stanza format and write the output to the xCAT database, enter:
 | |
| 
 | |
|  rscan hmc02 -z -w
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   Server-9458-100992001Y_B:
 | |
|     objtype=node
 | |
|     nodetype=bpa
 | |
|     id=2
 | |
|     model=9458-100
 | |
|     serial=992001Y
 | |
|     hcp=hmc02
 | |
|     profile=
 | |
|     parent=
 | |
|     groups=bpa,all
 | |
|     mgt=hmc
 | |
|     cons=
 | |
| 
 | |
|   Server-9119-590-SN02C5F9E:
 | |
|     objtype=node
 | |
|     type=fsp
 | |
|     id=10
 | |
|     model=9119-590
 | |
|     serial=02C5F9E
 | |
|     hcp=hmc02
 | |
|     profile=
 | |
|     parent=Server-9458-100992001Y_B
 | |
|     groups=fsp,all
 | |
|     mgt=hmc
 | |
|     cons=
 | |
| 
 | |
|   lpar01:
 | |
|     objtype=node
 | |
|     nodetype=lpar,osi
 | |
|     id=1
 | |
|     model=
 | |
|     serial=
 | |
|     hcp=hmc02
 | |
|     profile=lpar01
 | |
|     parent=Server-9119-590-SN02C5F9E
 | |
|     groups=lpar,all
 | |
|     mgt=hmc
 | |
|     cons=hmc
 | |
| 
 | |
|   lpar02:
 | |
|     objtype=node
 | |
|     nodetype=lpar,osi
 | |
|     id=2
 | |
|     model=
 | |
|     serial=
 | |
|     hcp=hmc02
 | |
|     profile=lpar02
 | |
|     parent=Server-9119-590-SN02C5F9E
 | |
|     groups=lpar,all
 | |
|     mgt=hmc
 | |
|     cons=hmc
 | |
| 
 | |
| 4. To update definitions of nodes, which is managed by hmc03, enter:
 | |
| 
 | |
|  rscan hmc03 -u
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   #Updated following nodes:
 | |
|   type    name                           id      type-model  serial-number  address
 | |
|   fsp     Server-9125-F2A-SN0262672-B    3       9125-F2A    0262672        192.168.200.243
 | |
| 
 | |
| 5. To collects the node information from one or more hardware control points on zVM AND populate the database with details collected by rscan:
 | |
| 
 | |
|  rscan gpok2 -w
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   gpok2:
 | |
|     objtype=node
 | |
|     arch=s390x
 | |
|     os=sles10sp3
 | |
|     hcp=gpok3.endicott.ibm.com
 | |
|     userid=LINUX2
 | |
|     nodetype=vm
 | |
|     parent=POKDEV61
 | |
|     groups=all
 | |
|     mgt=zvm
 | |
| 
 | |
| 6. To scan the Flex system cluster:
 | |
| 
 | |
|  rscan cmm01
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   type    name                  id      type-model  serial-number  mpa        address
 | |
|   cmm     AMM680520153          0       789392X     100048A        cmm01      cmm01
 | |
|   blade   SN#YL10JH184067       1       789542X     10F752A        cmm01      12.0.0.9
 | |
|   xblade  SN#YL10JH184068       2       789542X     10F652A        cmm01      12.0.0.10
 | |
|   blade   SN#YL10JH184079       3       789542X     10F697A        cmm01      12.0.0.11
 | |
| 
 | |
| 7. To update the Flex system cluster:
 | |
| 
 | |
|  rscan cmm01 -u
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   cmm    [AMM680520153]         Matched To =>[cmm01]
 | |
|   blade  [SN#YL10JH184067]      Matched To =>[cmm01node01]
 | |
|   blade  [SN#YL10JH184079]      Matched To =>[cmm01node03]
 | |
| 
 | |
| 8. To scan the KVM host "hyp01", list all the KVM guest information on the KVM host in stanza format and write the KVM guest information into xCAT database:
 | |
| 
 | |
|  rscan hyp01 -z -w
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   kvm1
 | |
|     arch=x86_64
 | |
|     mac=
 | |
|     mgt=kvm
 | |
|     vmcpus=1
 | |
|     vmhost=hyp01
 | |
|     vmmemory=1024
 | |
|     vmnicnicmodel=virtio
 | |
|     vmnics=virbr0
 | |
|     vmstorage=/install/vms/kvm1.hda.qcow2
 | |
|   kvm2
 | |
|     arch=x86_64
 | |
|     mac=
 | |
|     mgt=kvm
 | |
|     vmcpus=2
 | |
|     vmhost=hyp01
 | |
|     vmmemory=1024
 | |
|     vmnicnicmodel=virtio
 | |
|     vmnics=virbr0
 | |
|     vmstorage=/install/vms/kvm2.hda.qcow2
 | |
| 
 | |
| 9. To update definitions of kvm guest, which is managed by hypervisor hyp01, enter:
 | |
| 
 | |
|  rscan hyp01 -u
 | |
| 
 | |
| Output is similar to:
 | |
| 
 | |
|   type    name     hypervisor     id     cpu     memory     nic     disk
 | |
|   kvm     kvm2     hyp01          12     2       1024       virbr0  /install/vms/kvm2.hda.qcow2
 | |
|   kvm     kvm1     hyp01          10     1       1024       virbr0  /install/vms/kvm1.hda.qcow2
 | |
| 
 | |
| =head1 FILES
 | |
| 
 | |
| /opt/xcat/bin/rscan
 | |
| 
 | |
| 
 | |
| =head1 SEE ALSO
 | |
| 
 | |
| L<lsslp(1)|lsslp.1>
 | |
| 
 | |
| 
 | |
| 
 |