Add optional values to ipmi.bmcport to support more fine-grained
configuration for Dell servers, and mirror the `ipmitool delloem`
capabilities:
lan set <Mode>
sets the NIC Selection Mode :
dedicated, shared with lom<idx>
lan set <Shared Failover Mode>
sets the shared Failover Mode :
shared with failover lom<idx>
shared with failover all loms,
shared with failover none.
This patch introduces the possibility to provide 3 (space-separated)
values for ipmi.bmcport:
1st value: 0 = shared / 1 = dedicated
2nd value shared LOM (1-4) (0 or no value means first available LOM)
3rd value: failover LOM (1-4) (0 means no failover, no value means all LOMs)
To ensure maximum compatibility with the default 0/1 shared/dedicated
scheme, the 2nd and 3rd values are optional, and will retain the
previous behavior when not specified.
Examples:
ipmi.bmcport value BMC interface configuration
0 Shared with first available interface, failover with
all LOMs (catch-all mode)
0 1 Shared with LOM1, failover all LOMs
0 1 2 Shared with LOM1, failover LOM2
0 2 0 Shared with LOM2, no failover
1 Dedicated