linggao
20bf9f90f6
added output display for switchdiscover command
2015-05-15 13:31:21 -04:00
ertaozh
6280270cd9
support to add/modify user/password for BMC with rspconfig
2015-05-15 05:24:32 -04:00
linggao
1d7df6b238
more code for switchdiscover command
2015-05-14 11:27:38 -04:00
ligc
c0f65b7ae7
remove install/netboot/statelite related flags from rmimage, liteimg and rinstall
2015-05-14 04:57:44 -04:00
ligc
4322c2b553
remove install|statelite|netboot from usage statements
2015-05-14 04:11:52 -04:00
ligc
2a107425ea
not sure what happended, fix the bad checkin 8f7633c9b55520f7b5cf88eedd4d523c01c6ec6c
2015-05-14 04:00:58 -04:00
ligc
8f7633c9b5
remove the install/netboot/statelite from the usage statements of nodeset, imgcapture, genimage and packimgage
2015-05-14 03:55:42 -04:00
jjohnson2
178a63cd4a
Add the build id of pending UEFI
...
If UEFI is pending on IBM/Lenovo x86 systems, present
the build id of what the next boot should bring.
2015-05-13 10:18:22 -04:00
ertaozh
ff20b96dba
1. appending "statement" within makedhcp rather than from nodeset, find corrent tftpserver for petitboot booting; 2. Use hvc0 for ppc64 genesis shell
2015-05-13 03:40:35 -04:00
WangXiaoPeng
fbb5fca652
defect 4553: make rinstall only output error message when certain node failed instead of stopping running
2015-05-12 22:47:35 -04:00
linggao
6155642aee
Allow switchdiscover command call corresponding subroutines
2015-05-12 14:47:52 -04:00
billwajda
f62bdf3121
fixed a syntax error in dhcp.pm
2015-05-12 05:50:02 -04:00
billwajda
a2c5a0be58
dhcp.pm: moved authoritative statement inside the network stanza
2015-05-12 05:50:02 -04:00
billwajda
05339e823e
updated dhcp.pm to put out a warning message when subnet/netmask for network in network table does not match network configured
2015-05-12 05:50:02 -04:00
ertaozh
3441bc337a
appending "statement" within makedhcp rather than from nodeset, this commit is for yaboot
2015-05-12 04:58:13 -04:00
amy0701
2107c99f2a
check if there is nmap or not
2015-05-12 04:31:59 -04:00
amy0701
8e5ddbd556
use ipmitool-xcat to find bmc
2015-05-12 03:22:58 -04:00
ertaozh
a84a9e655b
appending "statement" within makedhcp rather than from nodeset, this commit include grub2,petitboot and nimol netboot method
2015-05-12 01:36:55 -04:00
ligc
cc4dbdf8a3
change the nodeset install/netboot/statelite message from warning to error, and then exit
2015-05-11 04:51:13 -04:00
amy0701
2c0b4d2182
add nmap scan process framework, ipmi scan TBD
2015-05-08 05:57:06 -04:00
amy0701
f17fea2637
Create a plugin to handle bmcdiscover command
2015-05-07 21:52:38 -04:00
Casandra Qiu
f4e8d1c233
Create a plugin to handle switchdiscover command
2015-05-06 16:49:47 -04:00
immarvin
faabb8e54b
merge
2015-04-30 04:10:12 -04:00
jjohnson2
b0c839856d
Finish fix from previous commit
...
The change to remote behavior was not fully compensated
for in previous commit. Go farther and ensure that the
classic syntax is executed exactly is it was.
2015-04-29 15:51:10 -04:00
jjohnson2
ae5715849f
Restore backwards compatibility to !remote!
...
A change was made to allow '!remote!' to force indicate a NIC to be
relevant in case it wouldn't naturally occur. This broke existing
configurations where the NIC would naturally be 'active'. Attempt
to address by restoring the old match and enabling the new code
when an interface name is detected after '!remote!', but otherwise
act like pre-2.9.1 dhcp.pm
2015-04-29 15:01:25 -04:00
WangXiaoPeng
d6feb34e0c
defect 4657: PCM has requirement that the user/password of fsp are different with the ones of ipmi for ppcle node. That means our renergy command should read 'passwd:fsp' first, if it does not exist, then use the default passwd 'admin/admin' instead of use the password from ipmi.
2015-04-28 08:31:18 -04:00
immarvin
ffaa44b437
support partitionscript in ubuntu
2015-04-27 22:31:59 -04:00
WangXiaoPeng
e215c27a3c
energy.pm, remove the stanby fsp/bmc check since CIM interface has problem to do it. So that means if some attributes cannot be supported on stanby fsp, there might be issues. Will fix it when really encounter it.
2015-04-22 23:47:39 -04:00
linggao
82c90e2227
null node appstatus when status is noping for nodestat -u.
2015-04-21 16:51:59 -04:00
GONG Jie
d9cc96bc4f
Add more comments for bug#4502 fixing. Use /dev/hvc? instead of /dev/ttyS? for ppc64, ppc64le, ppc64el.
2015-04-16 16:52:41 +08:00
GONG Jie
9d90313aaf
Fix bug#4502
2015-04-16 15:49:07 +08:00
immarvin
43ec8b55ef
support persistent kernel cmdline after diskful installation
2015-04-10 02:54:01 -07:00
jjohnson2
5ac2c0a4d6
Improve IPMI FRU parsing for Lenovo Thinkservers
...
Lenovo Thinkservers provide logically addressed FRUs that
aren't typed as logical FRU. Change so that the
addressing rather than the type drives our behavior to
read or skip.
Thinkservers explicitly have a locator record for FRU 0.
Ignore such a locator record.
If a board info area is not followed by a product or
multirecord area, give the board area parsing code access
to the end of the area in case board info data runs
beyond the end of the claimed area.
2015-04-08 15:11:36 -04:00
Lei Ai
33f614b584
merge fix for 4634 from 2.9.1-pcm branch
2015-04-08 17:14:25 +08:00
Jia Zhao
0e227799b9
support geninitrd for PowerKVM Hypervisor
2015-04-08 13:20:25 +08:00
Jia Zhao
33b992ae81
support define powerKVM hypervisor in nodeimport
2015-04-07 16:55:44 +08:00
Jia Zhao
c339024112
update messages in nodeimport
2015-04-02 15:52:02 +08:00
Jia Zhao
b769c4b1bc
Update nodeimport error messages for kvm nodes
2015-04-02 15:23:09 +08:00
ertaozh
f844701198
fix bug 4555 lsslp -s PBMC does not honor -n flag, need to update nodetype attribute for predefined node after discoveried
2015-04-01 23:17:20 -04:00
jjohnson2
48ae224911
ESXi 6 changes
...
ESXi 6 is for the most part identical to ESXi5 in how it is managed.
Have the esxi5 specific code also cover esxi6
2015-03-31 09:51:11 -04:00
jjohnson2
4d3e209c3e
Push xCAT nodegroup membership to confluent
...
With noderanges, it would be very handy for xCAT
group membership to be reflected in confluent. Have
makeconfluentcfg push that data into confluent.
2015-03-30 15:25:33 -04:00
ertaozh
b2a04a221b
fix bug 4611: PowerNV stateful CN provision will hang at reboot stage
2015-03-30 04:56:42 -04:00
WangXiaoPeng
358e83a5bb
defect 4615: For renergy command against P8 node, support the concurrent performing node communication for multiple nodes.
2015-03-27 07:23:24 -04:00
Jia Zhao
b94a492b21
fix nodeset command error in PCM nodeimport
2015-03-27 14:42:49 +08:00
jjohnson2
39bc1e21a6
Change wvid to pass IP to client
...
When remote xCAT client is used, often the client will not have
the same name resolution in place as the management node. For
wvid, mitigate this by passing the IP address to the client.
If name resolution worked before, this should be no downside.
If routing also doesn't work, well the user is no worse off than
before at the moment.
2015-03-26 10:01:10 -04:00
Jia Zhao
5371f78dbb
setting vpd.uuid for powerkvm nodes during nodeimport
2015-03-24 15:30:17 +08:00
jjohnson2
ff3eee61f3
Merge branch 'master' of ssh://git.code.sf.net/p/xcat/xcat-core
2015-03-20 10:59:20 -04:00
jjohnson2
fb02c18853
Fix erroneous 'noping' in various circumstances
...
nmap's raw IP facility is prone to mistakes in various
environments. Disable the raw IP handling by
telling nmap to run as if it didn't have privilege
2015-03-20 10:58:26 -04:00
linggao
50a086327b
Fixed defect 4608: getmacs does not work for x222 nodes
2015-03-16 16:17:08 -04:00
daniceexi
56d468f669
defect 4603: fix the code logic of how to get the fsp of cec
2015-03-13 04:53:32 -04:00