2
0
mirror of https://github.com/xcat2/xcat-core.git synced 2025-05-31 10:06:39 +00:00

4170 Commits

Author SHA1 Message Date
linggao
20bf9f90f6 added output display for switchdiscover command 2015-05-15 13:31:21 -04:00
ertaozh
6280270cd9 support to add/modify user/password for BMC with rspconfig 2015-05-15 05:24:32 -04:00
linggao
1d7df6b238 more code for switchdiscover command 2015-05-14 11:27:38 -04:00
ligc
c0f65b7ae7 remove install/netboot/statelite related flags from rmimage, liteimg and rinstall 2015-05-14 04:57:44 -04:00
ligc
4322c2b553 remove install|statelite|netboot from usage statements 2015-05-14 04:11:52 -04:00
ligc
2a107425ea not sure what happended, fix the bad checkin 8f7633c9b55520f7b5cf88eedd4d523c01c6ec6c 2015-05-14 04:00:58 -04:00
ligc
8f7633c9b5 remove the install/netboot/statelite from the usage statements of nodeset, imgcapture, genimage and packimgage 2015-05-14 03:55:42 -04:00
jjohnson2
178a63cd4a Add the build id of pending UEFI
If UEFI is pending on IBM/Lenovo x86 systems, present
the build id of what the next boot should bring.
2015-05-13 10:18:22 -04:00
ertaozh
ff20b96dba 1. appending "statement" within makedhcp rather than from nodeset, find corrent tftpserver for petitboot booting; 2. Use hvc0 for ppc64 genesis shell 2015-05-13 03:40:35 -04:00
WangXiaoPeng
fbb5fca652 defect 4553: make rinstall only output error message when certain node failed instead of stopping running 2015-05-12 22:47:35 -04:00
linggao
6155642aee Allow switchdiscover command call corresponding subroutines 2015-05-12 14:47:52 -04:00
billwajda
f62bdf3121 fixed a syntax error in dhcp.pm 2015-05-12 05:50:02 -04:00
billwajda
a2c5a0be58 dhcp.pm: moved authoritative statement inside the network stanza 2015-05-12 05:50:02 -04:00
billwajda
05339e823e updated dhcp.pm to put out a warning message when subnet/netmask for network in network table does not match network configured 2015-05-12 05:50:02 -04:00
ertaozh
3441bc337a appending "statement" within makedhcp rather than from nodeset, this commit is for yaboot 2015-05-12 04:58:13 -04:00
amy0701
2107c99f2a check if there is nmap or not 2015-05-12 04:31:59 -04:00
amy0701
8e5ddbd556 use ipmitool-xcat to find bmc 2015-05-12 03:22:58 -04:00
ertaozh
a84a9e655b appending "statement" within makedhcp rather than from nodeset, this commit include grub2,petitboot and nimol netboot method 2015-05-12 01:36:55 -04:00
ligc
cc4dbdf8a3 change the nodeset install/netboot/statelite message from warning to error, and then exit 2015-05-11 04:51:13 -04:00
amy0701
2c0b4d2182 add nmap scan process framework, ipmi scan TBD 2015-05-08 05:57:06 -04:00
amy0701
f17fea2637 Create a plugin to handle bmcdiscover command 2015-05-07 21:52:38 -04:00
Casandra Qiu
f4e8d1c233 Create a plugin to handle switchdiscover command 2015-05-06 16:49:47 -04:00
immarvin
faabb8e54b merge 2015-04-30 04:10:12 -04:00
jjohnson2
b0c839856d Finish fix from previous commit
The change to remote behavior was not fully compensated
for in previous commit.  Go farther and ensure that the
classic syntax is executed exactly is it was.
2015-04-29 15:51:10 -04:00
jjohnson2
ae5715849f Restore backwards compatibility to !remote!
A change was made to allow '!remote!' to force indicate a NIC to be
relevant in case it wouldn't naturally occur.  This broke existing
configurations where the NIC would naturally be 'active'.  Attempt
to address by restoring the old match and enabling the new code
when an interface name is detected after '!remote!', but otherwise
act like pre-2.9.1 dhcp.pm
2015-04-29 15:01:25 -04:00
WangXiaoPeng
d6feb34e0c defect 4657: PCM has requirement that the user/password of fsp are different with the ones of ipmi for ppcle node. That means our renergy command should read 'passwd:fsp' first, if it does not exist, then use the default passwd 'admin/admin' instead of use the password from ipmi. 2015-04-28 08:31:18 -04:00
immarvin
ffaa44b437 support partitionscript in ubuntu 2015-04-27 22:31:59 -04:00
WangXiaoPeng
e215c27a3c energy.pm, remove the stanby fsp/bmc check since CIM interface has problem to do it. So that means if some attributes cannot be supported on stanby fsp, there might be issues. Will fix it when really encounter it. 2015-04-22 23:47:39 -04:00
linggao
82c90e2227 null node appstatus when status is noping for nodestat -u. 2015-04-21 16:51:59 -04:00
GONG Jie
d9cc96bc4f Add more comments for bug#4502 fixing. Use /dev/hvc? instead of /dev/ttyS? for ppc64, ppc64le, ppc64el. 2015-04-16 16:52:41 +08:00
GONG Jie
9d90313aaf Fix bug#4502 2015-04-16 15:49:07 +08:00
immarvin
43ec8b55ef support persistent kernel cmdline after diskful installation 2015-04-10 02:54:01 -07:00
jjohnson2
5ac2c0a4d6 Improve IPMI FRU parsing for Lenovo Thinkservers
Lenovo Thinkservers provide logically addressed FRUs that
aren't typed as logical FRU.  Change so that the
addressing rather than the type drives our behavior to
read or skip.

Thinkservers explicitly have a locator record for FRU 0.
Ignore such a locator record.

If a board info area is not followed by a product or
multirecord area, give the board area parsing code access
to the end of the area in case board info data runs
beyond the end of the claimed area.
2015-04-08 15:11:36 -04:00
Lei Ai
33f614b584 merge fix for 4634 from 2.9.1-pcm branch 2015-04-08 17:14:25 +08:00
Jia Zhao
0e227799b9 support geninitrd for PowerKVM Hypervisor 2015-04-08 13:20:25 +08:00
Jia Zhao
33b992ae81 support define powerKVM hypervisor in nodeimport 2015-04-07 16:55:44 +08:00
Jia Zhao
c339024112 update messages in nodeimport 2015-04-02 15:52:02 +08:00
Jia Zhao
b769c4b1bc Update nodeimport error messages for kvm nodes 2015-04-02 15:23:09 +08:00
ertaozh
f844701198 fix bug 4555 lsslp -s PBMC does not honor -n flag, need to update nodetype attribute for predefined node after discoveried 2015-04-01 23:17:20 -04:00
jjohnson2
48ae224911 ESXi 6 changes
ESXi 6 is for the most part identical to ESXi5 in how it is managed.
Have the esxi5 specific code also cover esxi6
2015-03-31 09:51:11 -04:00
jjohnson2
4d3e209c3e Push xCAT nodegroup membership to confluent
With noderanges, it would be very handy for xCAT
group membership to be reflected in confluent.  Have
makeconfluentcfg push that data into confluent.
2015-03-30 15:25:33 -04:00
ertaozh
b2a04a221b fix bug 4611: PowerNV stateful CN provision will hang at reboot stage 2015-03-30 04:56:42 -04:00
WangXiaoPeng
358e83a5bb defect 4615: For renergy command against P8 node, support the concurrent performing node communication for multiple nodes. 2015-03-27 07:23:24 -04:00
Jia Zhao
b94a492b21 fix nodeset command error in PCM nodeimport 2015-03-27 14:42:49 +08:00
jjohnson2
39bc1e21a6 Change wvid to pass IP to client
When remote xCAT client is used, often the client will not have
the same name resolution in place as the management node.  For
wvid, mitigate this by passing the IP address to the client.
If name resolution worked before, this should be no downside.
If routing also doesn't work, well the user is no worse off than
before at the moment.
2015-03-26 10:01:10 -04:00
Jia Zhao
5371f78dbb setting vpd.uuid for powerkvm nodes during nodeimport 2015-03-24 15:30:17 +08:00
jjohnson2
ff3eee61f3 Merge branch 'master' of ssh://git.code.sf.net/p/xcat/xcat-core 2015-03-20 10:59:20 -04:00
jjohnson2
fb02c18853 Fix erroneous 'noping' in various circumstances
nmap's raw IP facility is prone to mistakes in various
environments.  Disable the raw IP handling by
telling nmap to run as if it didn't have privilege
2015-03-20 10:58:26 -04:00
linggao
50a086327b Fixed defect 4608: getmacs does not work for x222 nodes 2015-03-16 16:17:08 -04:00
daniceexi
56d468f669 defect 4603: fix the code logic of how to get the fsp of cec 2015-03-13 04:53:32 -04:00