Power9 Firmware Update
|
||||
======================
|
||||
|
||||
.. toctree::
|
||||
:maxdepth: 2
|
||||
|
||||
ipmi.rst
|
||||
openbmc.rst
|
38
docs/source/references/coral/cluster_mgmt/firmware/ipmi.rst
Normal file
38
docs/source/references/coral/cluster_mgmt/firmware/ipmi.rst
Normal file
@ -0,0 +1,38 @@
|
||||
IPMI Firmware Update
|
||||
====================
|
||||
|
||||
The process for updating firmware on the IBM Power9 Server (Boston) is documented below.
|
||||
|
||||
|
||||
Collect the required files
|
||||
--------------------------
|
||||
|
||||
Collect the following files and put them into a directory on the Management Node.
|
||||
|
||||
* pUpdate
|
||||
* pnor
|
||||
* bmc
|
||||
|
||||
Flash Firmware
|
||||
--------------
|
||||
|
||||
Using xCAT ``rflash`` command, specify the directory containing the files with the ``-d`` option. ::
|
||||
|
||||
rflash <noderange> -d /path-to-directory/
|
||||
|
||||
The ``pUpdate`` utility is leveraged in doing the firmware update against the target node and will do the following:
|
||||
|
||||
* power off the host
|
||||
* flash bmc and reboot
|
||||
* flash pnor
|
||||
* power on the host
|
||||
|
||||
Monitor the progress for the nodes by looking at the files under ``/var/log/xcat/rflash/``.
|
||||
|
||||
Validatation
|
||||
------------
|
||||
|
||||
Use the ``rinv`` command to validate firmware level: ::
|
||||
|
||||
rinv <noderange> firm | xcoll
|
||||
|
@ -0,0 +1,74 @@
|
||||
OpenBMC Firmware Update
|
||||
=======================
|
||||
|
||||
The process of updating firmware on the OpenBMC managed servers is documented below.
|
||||
|
||||
The sequence of events that must happen is the following:
|
||||
|
||||
* Power off the Host
|
||||
* Update and Activate PNOR
|
||||
* Update and Activate BMC
|
||||
* Reboot the BMC (applies BMC)
|
||||
* Power on the Host (applies PNOR)
|
||||
|
||||
**Note:** xCAT is working on streamlining this process to reduce the flexibility of the above steps at the convenience of the Administrator to handle the necessary reboots. See `Issue #4245 <https://github.com/xcat2/xcat-core/issues/4245>`_
|
||||
|
||||
|
||||
Power off Host
|
||||
--------------
|
||||
|
||||
Use the rpower command to power off the host: ::
|
||||
|
||||
rpower <noderange> off
|
||||
|
||||
Update and Activate PNOR Firmware
|
||||
---------------------------------
|
||||
|
||||
Use the rflash command to upload and activate the PNOR firmware: ::
|
||||
|
||||
rflash <noderange> -a /path/to/witherspoon.pnor.squashfs.tar
|
||||
|
||||
**Note:** The ``-a`` option does an upload and activate in one step, after firmware is activated, use the ``rflash <noderange> -l`` to view. The ``rflash`` command shows ``(*)`` as the active firmware and ``(+)`` on the firmware that requires reboot to become effective.
|
||||
|
||||
Update and Activate BMC Firmware
|
||||
--------------------------------
|
||||
|
||||
Use the rflash command to upload and activate the PNOR firmware: ::
|
||||
|
||||
rflash <noderange> -a /path/to/obmc-phosphor-image-witherspoon.ubi.mtd.tar
|
||||
|
||||
**Note:** The ``-a`` option does an upload and activate in one step, after firmware is activated, use the ``rflash <noderange> -l`` to view. The ``rflash`` command shows ``(*)`` as the active firmware and ``(+)`` on the firmware that requires reboot to become effective.
|
||||
|
||||
Reboot the BMC
|
||||
--------------
|
||||
|
||||
Use the ``rpower`` command to reboot the BMC: ::
|
||||
|
||||
rpower <noderange> bmcreboot`
|
||||
|
||||
The BMC will take 2-5 minutes to reboot, check the status using: ``rpower <noderange> bmcstate`` and wait for ``BMCReady`` to be returned.
|
||||
|
||||
**Known Issue:** On reboot, the first call to the BMC after reboot, xCAT will return ``Error: BMC did not respond within 10 seconds, retry the command.``. Please retry.
|
||||
|
||||
|
||||
Power on Host
|
||||
-------------
|
||||
|
||||
User the ``rpower`` command to power on the Host: ::
|
||||
|
||||
rpower <noderange> on
|
||||
|
||||
|
||||
Validation
|
||||
----------
|
||||
|
||||
Use one of the following commands to validate firmware levels are in sync:
|
||||
|
||||
* Use the ``rinv`` command to validate firmware level: ::
|
||||
|
||||
rinv <noderange> firm -V | grep -i ibm | grep "\*" | xcoll
|
||||
|
||||
* Use the ``rflash`` command to validate the firmware level: ::
|
||||
|
||||
rflash <noderange> -l | grep "\*" | xcoll
|
||||
|
7
docs/source/references/coral/cluster_mgmt/index.rst
Normal file
7
docs/source/references/coral/cluster_mgmt/index.rst
Normal file
@ -0,0 +1,7 @@
|
||||
Cluster Management
|
||||
==================
|
||||
|
||||
.. toctree::
|
||||
:maxdepth: 2
|
||||
|
||||
firmware/index.rst
|
@ -7,6 +7,7 @@ CORAL stands for Collaboration of Oak Ridge, Argonne, and Livermore and is solut
|
||||
.. toctree::
|
||||
:maxdepth: 2
|
||||
|
||||
cluster_mgmt/index.rst
|
||||
known_issues/index.rst
|
||||
.. mn/index.rst
|
||||
.. discovery/index.rst
|
||||
|
Loading…
x
Reference in New Issue
Block a user