mirror of
				https://github.com/xcat2/xcat-core.git
				synced 2025-10-30 19:02:27 +00:00 
			
		
		
		
	Check in rst files created by man page changes for PDU
This commit is contained in:
		| @@ -142,14 +142,16 @@ Processor for a single or range of nodes and groups. | ||||
| \ **powertime**\  | ||||
|   | ||||
|  Retrieves total power uptime.  This value only increases, unless | ||||
|  the Service Processor flash gets updated. | ||||
|  the Service Processor flash gets updated.  This option is not valid | ||||
|  for x86 architecture systems. | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **reboot**\  | ||||
|   | ||||
|  Retrieves  total  number of reboots.  This value only increases, | ||||
|  unless the Service Processor flash gets updated. | ||||
|  unless the Service Processor flash gets updated.  This option | ||||
|  is not valid for x86 architecture systems. | ||||
|   | ||||
|  | ||||
|  | ||||
|   | ||||
| @@ -19,7 +19,7 @@ NAME | ||||
| **************** | ||||
|  | ||||
|  | ||||
| \ **xdshbak**\  [\ **-c**\  | \ **-x**\  | \ **-h**\  | \ **-q**\ ] | ||||
| \ **xdshbak**\  [\ **-c**\  | \ **-x**\  [ \ **-b**\  ] | \ **-h**\  | \ **-q**\ ] | ||||
|  | ||||
|  | ||||
| *********** | ||||
| @@ -93,6 +93,9 @@ the output by hostname for easier viewing: | ||||
|   . | ||||
|  | ||||
|  | ||||
| If the \ **-b**\  flag is specified in addition to \ **-x**\ , the hostname at the beginning | ||||
| of each line is stripped. | ||||
|  | ||||
| Standard Error | ||||
| ============== | ||||
|  | ||||
| @@ -109,6 +112,13 @@ OPTIONS | ||||
|  | ||||
|  | ||||
|  | ||||
| \ **-b**\  | ||||
|   | ||||
|  Strip the host prefix from the beginning of the lines. This only | ||||
|  works with the \ **-x**\  option. | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **-c**\  | ||||
|   | ||||
|  If the output from multiple nodes is identical it will be collapsed | ||||
|   | ||||
| @@ -585,6 +585,18 @@ passwd(5)|passwd.5 | ||||
|   | ||||
|  | ||||
|  | ||||
| pdu(5)|pdu.5 | ||||
|   | ||||
|  Parameters to use when interrogating pdus | ||||
|   | ||||
|  | ||||
|  | ||||
| pduoutlet(5)|pduoutlet.5 | ||||
|   | ||||
|  Contains list of outlet numbers on the pdu each node is connected to. | ||||
|   | ||||
|  | ||||
|  | ||||
| performance(5)|performance.5 | ||||
|   | ||||
|  Describes the system performance every interval unit of time. | ||||
|   | ||||
| @@ -19,7 +19,7 @@ SYNOPSIS | ||||
| ******** | ||||
|  | ||||
|  | ||||
| \ **group Attributes:**\   \ *addkcmdline*\ , \ *arch*\ , \ *authdomain*\ , \ *bmc*\ , \ *bmcpassword*\ , \ *bmcport*\ , \ *bmcusername*\ , \ *bmcvlantag*\ , \ *cfgmgr*\ , \ *cfgmgtroles*\ , \ *cfgserver*\ , \ *chain*\ , \ *chassis*\ , \ *cmdmapping*\ , \ *cons*\ , \ *conserver*\ , \ *consoleondemand*\ , \ *cpucount*\ , \ *cputype*\ , \ *currchain*\ , \ *currstate*\ , \ *dhcpinterfaces*\ , \ *disksize*\ , \ *displayname*\ , \ *dockercpus*\ , \ *dockerflag*\ , \ *dockerhost*\ , \ *dockermemory*\ , \ *dockernics*\ , \ *domainadminpassword*\ , \ *domainadminuser*\ , \ *domaintype*\ , \ *getmac*\ , \ *groupname*\ , \ *grouptype*\ , \ *hcp*\ , \ *height*\ , \ *hostcluster*\ , \ *hostinterface*\ , \ *hostmanager*\ , \ *hostnames*\ , \ *hosttype*\ , \ *hwtype*\ , \ *id*\ , \ *initrd*\ , \ *installnic*\ , \ *interface*\ , \ *ip*\ , \ *iscsipassword*\ , \ *iscsiserver*\ , \ *iscsitarget*\ , \ *iscsiuserid*\ , \ *kcmdline*\ , \ *kernel*\ , \ *linkports*\ , \ *mac*\ , \ *membergroups*\ , \ *members*\ , \ *memory*\ , \ *mgt*\ , \ *micbridge*\ , \ *michost*\ , \ *micid*\ , \ *miconboot*\ , \ *micpowermgt*\ , \ *micvlog*\ , \ *migrationdest*\ , \ *monserver*\ , \ *mpa*\ , \ *mtm*\ , \ *nameservers*\ , \ *netboot*\ , \ *nfsdir*\ , \ *nfsserver*\ , \ *nicaliases*\ , \ *niccustomscripts*\ , \ *nicdevices*\ , \ *nicextraparams*\ , \ *nichostnameprefixes*\ , \ *nichostnamesuffixes*\ , \ *nicips*\ , \ *nicnetworks*\ , \ *nicsadapter*\ , \ *nictypes*\ , \ *nimserver*\ , \ *nodetype*\ , \ *ondiscover*\ , \ *os*\ , \ *osvolume*\ , \ *otherinterfaces*\ , \ *ou*\ , \ *parent*\ , \ *passwd.HMC*\ , \ *passwd.admin*\ , \ *passwd.celogin*\ , \ *passwd.general*\ , \ *passwd.hscroot*\ , \ *password*\ , \ *postbootscripts*\ , \ *postscripts*\ , \ *power*\ , \ *pprofile*\ , \ *prescripts-begin*\ , \ *prescripts-end*\ , \ *primarynic*\ , \ *productkey*\ , \ *profile*\ , \ *protocol*\ , \ *provmethod*\ , \ *rack*\ , \ *room*\ , \ *routenames*\ , \ *serial*\ , \ *serialflow*\ , \ *serialport*\ , \ *serialspeed*\ , \ *servicenode*\ , \ *setupconserver*\ , \ *setupdhcp*\ , \ *setupftp*\ , \ *setupipforward*\ , \ *setupldap*\ , \ *setupnameserver*\ , \ *setupnfs*\ , \ *setupnim*\ , \ *setupntp*\ , \ *setupproxydhcp*\ , \ *setuptftp*\ , \ *sfp*\ , \ *side*\ , \ *slot*\ , \ *slotid*\ , \ *slots*\ , \ *snmpauth*\ , \ *snmppassword*\ , \ *snmpprivacy*\ , \ *snmpusername*\ , \ *snmpversion*\ , \ *storagcontroller*\ , \ *storagetype*\ , \ *supernode*\ , \ *supportedarchs*\ , \ *supportproxydhcp*\ , \ *switch*\ , \ *switchinterface*\ , \ *switchport*\ , \ *switchtype*\ , \ *switchvlan*\ , \ *syslog*\ , \ *termport*\ , \ *termserver*\ , \ *tftpdir*\ , \ *tftpserver*\ , \ *unit*\ , \ *urlpath*\ , \ *usercomment*\ , \ *userid*\ , \ *username*\ , \ *vmbeacon*\ , \ *vmbootorder*\ , \ *vmcfgstore*\ , \ *vmcluster*\ , \ *vmcpus*\ , \ *vmhost*\ , \ *vmmanager*\ , \ *vmmaster*\ , \ *vmmemory*\ , \ *vmnicnicmodel*\ , \ *vmnics*\ , \ *vmothersetting*\ , \ *vmphyslots*\ , \ *vmstorage*\ , \ *vmstoragecache*\ , \ *vmstorageformat*\ , \ *vmstoragemodel*\ , \ *vmtextconsole*\ , \ *vmvirtflags*\ , \ *vmvncport*\ , \ *webport*\ , \ *wherevals*\ , \ *xcatmaster*\  | ||||
| \ **group Attributes:**\   \ *addkcmdline*\ , \ *arch*\ , \ *authdomain*\ , \ *bmc*\ , \ *bmcpassword*\ , \ *bmcport*\ , \ *bmcusername*\ , \ *bmcvlantag*\ , \ *cfgmgr*\ , \ *cfgmgtroles*\ , \ *cfgserver*\ , \ *chain*\ , \ *chassis*\ , \ *cmdmapping*\ , \ *cons*\ , \ *conserver*\ , \ *consoleondemand*\ , \ *cpucount*\ , \ *cputype*\ , \ *currchain*\ , \ *currstate*\ , \ *dhcpinterfaces*\ , \ *disksize*\ , \ *displayname*\ , \ *dockercpus*\ , \ *dockerflag*\ , \ *dockerhost*\ , \ *dockermemory*\ , \ *dockernics*\ , \ *domainadminpassword*\ , \ *domainadminuser*\ , \ *domaintype*\ , \ *getmac*\ , \ *groupname*\ , \ *grouptype*\ , \ *hcp*\ , \ *height*\ , \ *hostcluster*\ , \ *hostinterface*\ , \ *hostmanager*\ , \ *hostnames*\ , \ *hosttype*\ , \ *hwtype*\ , \ *id*\ , \ *initrd*\ , \ *installnic*\ , \ *interface*\ , \ *ip*\ , \ *iscsipassword*\ , \ *iscsiserver*\ , \ *iscsitarget*\ , \ *iscsiuserid*\ , \ *kcmdline*\ , \ *kernel*\ , \ *linkports*\ , \ *mac*\ , \ *machinetype*\ , \ *membergroups*\ , \ *members*\ , \ *memory*\ , \ *mgt*\ , \ *micbridge*\ , \ *michost*\ , \ *micid*\ , \ *miconboot*\ , \ *micpowermgt*\ , \ *micvlog*\ , \ *migrationdest*\ , \ *modelnum*\ , \ *monserver*\ , \ *mpa*\ , \ *mtm*\ , \ *nameservers*\ , \ *netboot*\ , \ *nfsdir*\ , \ *nfsserver*\ , \ *nicaliases*\ , \ *niccustomscripts*\ , \ *nicdevices*\ , \ *nicextraparams*\ , \ *nichostnameprefixes*\ , \ *nichostnamesuffixes*\ , \ *nicips*\ , \ *nicnetworks*\ , \ *nicsadapter*\ , \ *nictypes*\ , \ *nimserver*\ , \ *nodetype*\ , \ *ondiscover*\ , \ *os*\ , \ *osvolume*\ , \ *otherinterfaces*\ , \ *ou*\ , \ *outletcount*\ , \ *parent*\ , \ *passwd.HMC*\ , \ *passwd.admin*\ , \ *passwd.celogin*\ , \ *passwd.general*\ , \ *passwd.hscroot*\ , \ *password*\ , \ *pdu*\ , \ *postbootscripts*\ , \ *postscripts*\ , \ *power*\ , \ *pprofile*\ , \ *prescripts-begin*\ , \ *prescripts-end*\ , \ *primarynic*\ , \ *productkey*\ , \ *profile*\ , \ *protocol*\ , \ *provmethod*\ , \ *rack*\ , \ *room*\ , \ *routenames*\ , \ *serial*\ , \ *serialflow*\ , \ *serialnum*\ , \ *serialport*\ , \ *serialspeed*\ , \ *servicenode*\ , \ *setupconserver*\ , \ *setupdhcp*\ , \ *setupftp*\ , \ *setupipforward*\ , \ *setupldap*\ , \ *setupnameserver*\ , \ *setupnfs*\ , \ *setupnim*\ , \ *setupntp*\ , \ *setupproxydhcp*\ , \ *setuptftp*\ , \ *sfp*\ , \ *side*\ , \ *slot*\ , \ *slotid*\ , \ *slots*\ , \ *snmpauth*\ , \ *snmppassword*\ , \ *snmpprivacy*\ , \ *snmpusername*\ , \ *snmpversion*\ , \ *storagcontroller*\ , \ *storagetype*\ , \ *supernode*\ , \ *supportedarchs*\ , \ *supportproxydhcp*\ , \ *switch*\ , \ *switchinterface*\ , \ *switchport*\ , \ *switchtype*\ , \ *switchvlan*\ , \ *syslog*\ , \ *termport*\ , \ *termserver*\ , \ *tftpdir*\ , \ *tftpserver*\ , \ *unit*\ , \ *urlpath*\ , \ *usercomment*\ , \ *userid*\ , \ *username*\ , \ *vmbeacon*\ , \ *vmbootorder*\ , \ *vmcfgstore*\ , \ *vmcluster*\ , \ *vmcpus*\ , \ *vmhost*\ , \ *vmmanager*\ , \ *vmmaster*\ , \ *vmmemory*\ , \ *vmnicnicmodel*\ , \ *vmnics*\ , \ *vmothersetting*\ , \ *vmphyslots*\ , \ *vmstorage*\ , \ *vmstoragecache*\ , \ *vmstorageformat*\ , \ *vmstoragemodel*\ , \ *vmtextconsole*\ , \ *vmvirtflags*\ , \ *vmvncport*\ , \ *webport*\ , \ *wherevals*\ , \ *xcatmaster*\  | ||||
|  | ||||
|  | ||||
| *********** | ||||
| @@ -435,6 +435,12 @@ group Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **machinetype**\  (pdu.machinetype) | ||||
|   | ||||
|  The pdu machine type | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **membergroups**\  (nodegroup.membergroups) | ||||
|   | ||||
|  This attribute stores a comma-separated list of nodegroups that this nodegroup refers to. This attribute is only used by PCM. | ||||
| @@ -501,6 +507,12 @@ group Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **modelnum**\  (pdu.modelnum) | ||||
|   | ||||
|  The pdu model number | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **monserver**\  (noderes.monserver) | ||||
|   | ||||
|  The monitoring aggregation point for this node. The format is "x,y" where x is the ip address as known by the management node and y is the ip address as known by the node. | ||||
| @@ -695,6 +707,12 @@ group Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **outletcount**\  (pdu.outletcount) | ||||
|   | ||||
|  The pdu outlet count | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **parent**\  (ppc.parent) | ||||
|   | ||||
|  For LPARs: the CEC; for FSPs: the CEC; for CEC: the frame (if one exists); for BPA: the frame; for frame: the building block number (which consists 1 or more service nodes and compute/storage nodes that are serviced by them - optional). | ||||
| @@ -749,6 +767,12 @@ group Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **pdu**\  (pduoutlet.pdu) | ||||
|   | ||||
|  a comma-separated list of outlet number for each PDU, ex: pdu1:outlet1,pdu2:outlet1 | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **postbootscripts**\  (postscripts.postbootscripts) | ||||
|   | ||||
|  Comma separated list of scripts that should be run on this node after diskful installation or diskless boot. Each script can take zero or more parameters. For example: "script1 p1 p2,script2,...". On AIX these scripts are run during the processing of /etc/inittab.  On Linux they are run at the init.d time. xCAT automatically adds the scripts in the xcatdefaults.postbootscripts attribute to run first in the list. | ||||
| @@ -866,6 +890,12 @@ group Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **serialnum**\  (pdu.serialnum) | ||||
|   | ||||
|  The pdu serial number | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **serialport**\  (nodehm.serialport) | ||||
|   | ||||
|  The serial port for this node, in the linux numbering style (0=COM1/ttyS0, 1=COM2/ttyS1).  For SOL on IBM blades, this is typically 1.  For rackmount IBM servers, this is typically 0. | ||||
|   | ||||
| @@ -19,7 +19,7 @@ SYNOPSIS | ||||
| ******** | ||||
|  | ||||
|  | ||||
| \ **node Attributes:**\   \ *addkcmdline*\ , \ *appstatus*\ , \ *appstatustime*\ , \ *arch*\ , \ *authdomain*\ , \ *bmc*\ , \ *bmcpassword*\ , \ *bmcport*\ , \ *bmcusername*\ , \ *bmcvlantag*\ , \ *cfgmgr*\ , \ *cfgmgtroles*\ , \ *cfgserver*\ , \ *chain*\ , \ *chassis*\ , \ *cmdmapping*\ , \ *cons*\ , \ *conserver*\ , \ *consoleondemand*\ , \ *cpucount*\ , \ *cputype*\ , \ *currchain*\ , \ *currstate*\ , \ *dhcpinterfaces*\ , \ *disksize*\ , \ *displayname*\ , \ *dockercpus*\ , \ *dockerflag*\ , \ *dockerhost*\ , \ *dockermemory*\ , \ *dockernics*\ , \ *domainadminpassword*\ , \ *domainadminuser*\ , \ *domaintype*\ , \ *getmac*\ , \ *groups*\ , \ *hcp*\ , \ *height*\ , \ *hidden*\ , \ *hostcluster*\ , \ *hostinterface*\ , \ *hostmanager*\ , \ *hostnames*\ , \ *hosttype*\ , \ *hwtype*\ , \ *id*\ , \ *initrd*\ , \ *installnic*\ , \ *interface*\ , \ *ip*\ , \ *iscsipassword*\ , \ *iscsiserver*\ , \ *iscsitarget*\ , \ *iscsiuserid*\ , \ *kcmdline*\ , \ *kernel*\ , \ *linkports*\ , \ *mac*\ , \ *memory*\ , \ *mgt*\ , \ *micbridge*\ , \ *michost*\ , \ *micid*\ , \ *miconboot*\ , \ *micpowermgt*\ , \ *micvlog*\ , \ *migrationdest*\ , \ *monserver*\ , \ *mpa*\ , \ *mtm*\ , \ *nameservers*\ , \ *netboot*\ , \ *nfsdir*\ , \ *nfsserver*\ , \ *nicaliases*\ , \ *niccustomscripts*\ , \ *nicdevices*\ , \ *nicextraparams*\ , \ *nichostnameprefixes*\ , \ *nichostnamesuffixes*\ , \ *nicips*\ , \ *nicnetworks*\ , \ *nicsadapter*\ , \ *nictypes*\ , \ *nimserver*\ , \ *node*\ , \ *nodetype*\ , \ *ondiscover*\ , \ *os*\ , \ *osvolume*\ , \ *otherinterfaces*\ , \ *ou*\ , \ *parent*\ , \ *passwd.HMC*\ , \ *passwd.admin*\ , \ *passwd.celogin*\ , \ *passwd.general*\ , \ *passwd.hscroot*\ , \ *password*\ , \ *postbootscripts*\ , \ *postscripts*\ , \ *power*\ , \ *pprofile*\ , \ *prescripts-begin*\ , \ *prescripts-end*\ , \ *primarynic*\ , \ *primarysn*\ , \ *productkey*\ , \ *profile*\ , \ *protocol*\ , \ *provmethod*\ , \ *rack*\ , \ *room*\ , \ *routenames*\ , \ *serial*\ , \ *serialflow*\ , \ *serialport*\ , \ *serialspeed*\ , \ *servicenode*\ , \ *setupconserver*\ , \ *setupdhcp*\ , \ *setupftp*\ , \ *setupipforward*\ , \ *setupldap*\ , \ *setupnameserver*\ , \ *setupnfs*\ , \ *setupnim*\ , \ *setupntp*\ , \ *setupproxydhcp*\ , \ *setuptftp*\ , \ *sfp*\ , \ *side*\ , \ *slot*\ , \ *slotid*\ , \ *slots*\ , \ *snmpauth*\ , \ *snmppassword*\ , \ *snmpprivacy*\ , \ *snmpusername*\ , \ *snmpversion*\ , \ *status*\ , \ *statustime*\ , \ *storagcontroller*\ , \ *storagetype*\ , \ *supernode*\ , \ *supportedarchs*\ , \ *supportproxydhcp*\ , \ *switch*\ , \ *switchinterface*\ , \ *switchport*\ , \ *switchtype*\ , \ *switchvlan*\ , \ *syslog*\ , \ *termport*\ , \ *termserver*\ , \ *tftpdir*\ , \ *tftpserver*\ , \ *unit*\ , \ *updatestatus*\ , \ *updatestatustime*\ , \ *urlpath*\ , \ *usercomment*\ , \ *userid*\ , \ *username*\ , \ *vmbeacon*\ , \ *vmbootorder*\ , \ *vmcfgstore*\ , \ *vmcluster*\ , \ *vmcpus*\ , \ *vmhost*\ , \ *vmmanager*\ , \ *vmmaster*\ , \ *vmmemory*\ , \ *vmnicnicmodel*\ , \ *vmnics*\ , \ *vmothersetting*\ , \ *vmphyslots*\ , \ *vmstorage*\ , \ *vmstoragecache*\ , \ *vmstorageformat*\ , \ *vmstoragemodel*\ , \ *vmtextconsole*\ , \ *vmvirtflags*\ , \ *vmvncport*\ , \ *webport*\ , \ *xcatmaster*\ , \ *zonename*\  | ||||
| \ **node Attributes:**\   \ *addkcmdline*\ , \ *appstatus*\ , \ *appstatustime*\ , \ *arch*\ , \ *authdomain*\ , \ *bmc*\ , \ *bmcpassword*\ , \ *bmcport*\ , \ *bmcusername*\ , \ *bmcvlantag*\ , \ *cfgmgr*\ , \ *cfgmgtroles*\ , \ *cfgserver*\ , \ *chain*\ , \ *chassis*\ , \ *cmdmapping*\ , \ *cons*\ , \ *conserver*\ , \ *consoleondemand*\ , \ *cpucount*\ , \ *cputype*\ , \ *currchain*\ , \ *currstate*\ , \ *dhcpinterfaces*\ , \ *disksize*\ , \ *displayname*\ , \ *dockercpus*\ , \ *dockerflag*\ , \ *dockerhost*\ , \ *dockermemory*\ , \ *dockernics*\ , \ *domainadminpassword*\ , \ *domainadminuser*\ , \ *domaintype*\ , \ *getmac*\ , \ *groups*\ , \ *hcp*\ , \ *height*\ , \ *hidden*\ , \ *hostcluster*\ , \ *hostinterface*\ , \ *hostmanager*\ , \ *hostnames*\ , \ *hosttype*\ , \ *hwtype*\ , \ *id*\ , \ *initrd*\ , \ *installnic*\ , \ *interface*\ , \ *ip*\ , \ *iscsipassword*\ , \ *iscsiserver*\ , \ *iscsitarget*\ , \ *iscsiuserid*\ , \ *kcmdline*\ , \ *kernel*\ , \ *linkports*\ , \ *mac*\ , \ *machinetype*\ , \ *memory*\ , \ *mgt*\ , \ *micbridge*\ , \ *michost*\ , \ *micid*\ , \ *miconboot*\ , \ *micpowermgt*\ , \ *micvlog*\ , \ *migrationdest*\ , \ *modelnum*\ , \ *monserver*\ , \ *mpa*\ , \ *mtm*\ , \ *nameservers*\ , \ *netboot*\ , \ *nfsdir*\ , \ *nfsserver*\ , \ *nicaliases*\ , \ *niccustomscripts*\ , \ *nicdevices*\ , \ *nicextraparams*\ , \ *nichostnameprefixes*\ , \ *nichostnamesuffixes*\ , \ *nicips*\ , \ *nicnetworks*\ , \ *nicsadapter*\ , \ *nictypes*\ , \ *nimserver*\ , \ *node*\ , \ *nodetype*\ , \ *ondiscover*\ , \ *os*\ , \ *osvolume*\ , \ *otherinterfaces*\ , \ *ou*\ , \ *outletcount*\ , \ *parent*\ , \ *passwd.HMC*\ , \ *passwd.admin*\ , \ *passwd.celogin*\ , \ *passwd.general*\ , \ *passwd.hscroot*\ , \ *password*\ , \ *pdu*\ , \ *postbootscripts*\ , \ *postscripts*\ , \ *power*\ , \ *pprofile*\ , \ *prescripts-begin*\ , \ *prescripts-end*\ , \ *primarynic*\ , \ *primarysn*\ , \ *productkey*\ , \ *profile*\ , \ *protocol*\ , \ *provmethod*\ , \ *rack*\ , \ *room*\ , \ *routenames*\ , \ *serial*\ , \ *serialflow*\ , \ *serialnum*\ , \ *serialport*\ , \ *serialspeed*\ , \ *servicenode*\ , \ *setupconserver*\ , \ *setupdhcp*\ , \ *setupftp*\ , \ *setupipforward*\ , \ *setupldap*\ , \ *setupnameserver*\ , \ *setupnfs*\ , \ *setupnim*\ , \ *setupntp*\ , \ *setupproxydhcp*\ , \ *setuptftp*\ , \ *sfp*\ , \ *side*\ , \ *slot*\ , \ *slotid*\ , \ *slots*\ , \ *snmpauth*\ , \ *snmppassword*\ , \ *snmpprivacy*\ , \ *snmpusername*\ , \ *snmpversion*\ , \ *status*\ , \ *statustime*\ , \ *storagcontroller*\ , \ *storagetype*\ , \ *supernode*\ , \ *supportedarchs*\ , \ *supportproxydhcp*\ , \ *switch*\ , \ *switchinterface*\ , \ *switchport*\ , \ *switchtype*\ , \ *switchvlan*\ , \ *syslog*\ , \ *termport*\ , \ *termserver*\ , \ *tftpdir*\ , \ *tftpserver*\ , \ *unit*\ , \ *updatestatus*\ , \ *updatestatustime*\ , \ *urlpath*\ , \ *usercomment*\ , \ *userid*\ , \ *username*\ , \ *vmbeacon*\ , \ *vmbootorder*\ , \ *vmcfgstore*\ , \ *vmcluster*\ , \ *vmcpus*\ , \ *vmhost*\ , \ *vmmanager*\ , \ *vmmaster*\ , \ *vmmemory*\ , \ *vmnicnicmodel*\ , \ *vmnics*\ , \ *vmothersetting*\ , \ *vmphyslots*\ , \ *vmstorage*\ , \ *vmstoragecache*\ , \ *vmstorageformat*\ , \ *vmstoragemodel*\ , \ *vmtextconsole*\ , \ *vmvirtflags*\ , \ *vmvncport*\ , \ *webport*\ , \ *xcatmaster*\ , \ *zonename*\  | ||||
|  | ||||
|  | ||||
| *********** | ||||
| @@ -447,6 +447,12 @@ node Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **machinetype**\  (pdu.machinetype) | ||||
|   | ||||
|  The pdu machine type | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **memory**\  (hwinv.memory) | ||||
|   | ||||
|  The size of the memory for the node in MB. | ||||
| @@ -501,6 +507,12 @@ node Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **modelnum**\  (pdu.modelnum) | ||||
|   | ||||
|  The pdu model number | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **monserver**\  (noderes.monserver) | ||||
|   | ||||
|  The monitoring aggregation point for this node. The format is "x,y" where x is the ip address as known by the management node and y is the ip address as known by the node. | ||||
| @@ -701,6 +713,12 @@ node Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **outletcount**\  (pdu.outletcount) | ||||
|   | ||||
|  The pdu outlet count | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **parent**\  (ppc.parent) | ||||
|   | ||||
|  For LPARs: the CEC; for FSPs: the CEC; for CEC: the frame (if one exists); for BPA: the frame; for frame: the building block number (which consists 1 or more service nodes and compute/storage nodes that are serviced by them - optional). | ||||
| @@ -755,6 +773,12 @@ node Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **pdu**\  (pduoutlet.pdu) | ||||
|   | ||||
|  a comma-separated list of outlet number for each PDU, ex: pdu1:outlet1,pdu2:outlet1 | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **postbootscripts**\  (postscripts.postbootscripts) | ||||
|   | ||||
|  Comma separated list of scripts that should be run on this node after diskful installation or diskless boot. Each script can take zero or more parameters. For example: "script1 p1 p2,script2,...". On AIX these scripts are run during the processing of /etc/inittab.  On Linux they are run at the init.d time. xCAT automatically adds the scripts in the xcatdefaults.postbootscripts attribute to run first in the list. | ||||
| @@ -878,6 +902,12 @@ node Attributes: | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **serialnum**\  (pdu.serialnum) | ||||
|   | ||||
|  The pdu serial number | ||||
|   | ||||
|  | ||||
|  | ||||
| \ **serialport**\  (nodehm.serialport) | ||||
|   | ||||
|  The serial port for this node, in the linux numbering style (0=COM1/ttyS0, 1=COM2/ttyS1).  For SOL on IBM blades, this is typically 1.  For rackmount IBM servers, this is typically 0. | ||||
|   | ||||
		Reference in New Issue
	
	Block a user