mirror of
				https://github.com/xcat2/xcat-core.git
				synced 2025-10-30 19:02:27 +00:00 
			
		
		
		
	Format some of the wording in the configure password documentation
This commit is contained in:
		| @@ -3,46 +3,41 @@ Configure passwords | ||||
|  | ||||
| #. Configure the system password for the ``root`` user on the compute nodes. | ||||
|  | ||||
|      * Set using the :doc:`chtab </guides/admin-guides/references/man8/chtab.8>` command: (**Recommended**) :: | ||||
|    * Set using the :doc:`chtab </guides/admin-guides/references/man8/chtab.8>` command:  :: | ||||
|  | ||||
|           chtab key=system passwd.username=root passwd.password=abc123 | ||||
|        chtab key=system passwd.username=root passwd.password=abc123 | ||||
|  | ||||
|        To encrypt the password using ``openssl``, use the following command: :: | ||||
|      To encrypt the password using ``openssl``, use the following command: :: | ||||
|  | ||||
|           chtab key=system passwd.username=root passwd.password=`openssl passwd -1 abc123` | ||||
|  | ||||
|      * Directly edit the passwd table using the :doc:`tabedit </guides/admin-guides/references/man8/tabedit.8>` command.  | ||||
|        chtab key=system passwd.username=root passwd.password=`openssl passwd -1 abc123` | ||||
|  | ||||
|  | ||||
| #. Configure the passwords for Management modules of the compute nodes. | ||||
|  | ||||
|    * For IPMI/BMC managed systems: :: | ||||
|  | ||||
|          chtab key=ipmi passwd.username=USERID passwd.password=PASSW0RD | ||||
|          chtab key=ipmi passwd.username=ADMIN passwd.password=admin | ||||
|  | ||||
|    * For HMC managed systems: :: | ||||
|  | ||||
|          chtab key=hmc passwd.username=hscroot passwd.password=abc123  | ||||
|  | ||||
|      The username and password for the HMC can be assigned directly to the HMC node object definition in xCAT. This is needed when the HMC username/password is different for each HMC. :: | ||||
|        | ||||
|          mkdef -t node -o hmc1 groups=hmc,all nodetype=ppc hwtype=hmc mgt=hmc \ | ||||
|          username=hscroot password=hmcPassw0rd | ||||
|      If the username/password is different for multiple HMCs, set the ``username`` and ``password`` attribute for each HMC node object in xCAT | ||||
|  | ||||
|    * For Blade managed systems: :: | ||||
|  | ||||
|          chtab key=blade passwd.username=USERID passwd.password=PASSW0RD  | ||||
|  | ||||
|    * For FSP/BPA (Flexible Service Processor/Bulk Power Assembly), if the passwords are set to the factory defaults, you must change them before running and commands to them. :: | ||||
|    * For FSP/BPA (Flexible Service Processor/Bulk Power Assembly) the factory default passwords must be changed before running commands against them. :: | ||||
|  | ||||
|          rspconfig frame general_passwd=general,<newpassword> | ||||
|          rspconfig frame admin_passwd=admin,<newpassword> | ||||
|          rspconfig frame HMC_passwd=,<newpassword> | ||||
|  | ||||
|  | ||||
| #. If the REST API is being used configure a user and set a policy rule in xCAT. | ||||
| #. If using the xCAT REST API | ||||
|  | ||||
|     #. Create a non root user that will be used to make the REST API calls. :: | ||||
|     #. Create a non-root user that will be used to make the REST API calls. :: | ||||
|  | ||||
|         useradd xcatws | ||||
|         passwd xcatws # set the password | ||||
| @@ -56,4 +51,4 @@ Configure passwords | ||||
|         mkdef -t policy 6 name=xcatws rule=allow  | ||||
|  | ||||
|  | ||||
|    When making calls to the xCAT REST API, pass in the credentials using the following attributes: ``userName`` and ``userPW`` | ||||
|     When making calls to the xCAT REST API, pass in the credentials using the following attributes: ``userName`` and ``userPW`` | ||||
|   | ||||
		Reference in New Issue
	
	Block a user