mirror of
				https://github.com/xcat2/xcat-core.git
				synced 2025-10-31 11:22:27 +00:00 
			
		
		
		
	Remove trailing spaces in file docs/source/advanced/pdu/irpdu.rst
This commit is contained in:
		| @@ -18,34 +18,34 @@ Add a ``pdu`` attribute to the compute node definition in the form "PDU_Name:out | ||||
|     chdef cn01 pdu=f5pdu3:6,f5pdu3:7 | ||||
|  | ||||
|  | ||||
| The following commands are supported against a compute node:  | ||||
| The following commands are supported against a compute node: | ||||
|  | ||||
|    * Check the pdu status for a compute node: :: | ||||
|     | ||||
|  | ||||
|        # rpower cn01 pdustat | ||||
|          cn01: f5pdu3 outlet 6 is on | ||||
|          cn01: f5pdu3 outlet 7 is on | ||||
|  | ||||
|  | ||||
|    * Power off the PDU outlets for a compute node: ::  | ||||
|     | ||||
|    * Power off the PDU outlets for a compute node: :: | ||||
|  | ||||
|        # rpower cn01 pduoff | ||||
|          cn01: f5pdu3 outlet 6 is off | ||||
|          cn01: f5pdu3 outlet 7 is off | ||||
|  | ||||
|    * Power on the PDU outlets for a compute node: ::  | ||||
|     | ||||
|    * Power on the PDU outlets for a compute node: :: | ||||
|  | ||||
|        # rpower cn01 pduon | ||||
|          cn01: f5pdu3 outlet 6 is on | ||||
|          cn01: f5pdu3 outlet 7 is on | ||||
|  | ||||
|    * Power cycling the PDU outlets for a compute node: ::  | ||||
|     | ||||
|    * Power cycling the PDU outlets for a compute node: :: | ||||
|  | ||||
|        # rpower cn01 pdureset | ||||
|          cn01: f5pdu3 outlet 6 is reset  | ||||
|          cn01: f5pdu3 outlet 6 is reset | ||||
|          cn01: f5pdu3 outlet 7 is reset | ||||
|  | ||||
| The following commands are supported against a PDU:  | ||||
| The following commands are supported against a PDU: | ||||
|  | ||||
|    * To change hostname of IR PDU: :: | ||||
|  | ||||
| @@ -72,7 +72,7 @@ The following commands are supported against a PDU: | ||||
|          f5pdu3: outlet 12 is on | ||||
|  | ||||
|    * Power off the full PDU: :: | ||||
|     | ||||
|  | ||||
|        # rpower f5pdu3 off | ||||
|          f5pdu3: outlet 1 is off | ||||
|          f5pdu3: outlet 2 is off | ||||
| @@ -104,7 +104,7 @@ The following commands are supported against a PDU: | ||||
|          f5pdu3: outlet 12 is on | ||||
|  | ||||
|    * Power reset the full PDU: :: | ||||
|     | ||||
|  | ||||
|        # rpower f5pdu3 reset | ||||
|          f5pdu3: outlet 1 is reset | ||||
|          f5pdu3: outlet 2 is reset | ||||
| @@ -148,9 +148,9 @@ The following commands are supported against a PDU: | ||||
|          f6pdu15: outlet 3 Max Capacity of the current: 16000 mA | ||||
|          f6pdu15: outlet 3 Current Threshold Warning: 9600 mA | ||||
|          f6pdu15: outlet 3 Current Threshold Critical: 12800 mA | ||||
|          f6pdu15: outlet 3 Last Power Reading: 217 Wattsv   | ||||
|     | ||||
| **Note:** For BMC based compute nodes, turning the PDU outlet power on does not automatically power on the compute side.  Users will need to issue ``rpower <node> on`` to power on the compute side after the BMC boots.  | ||||
|          f6pdu15: outlet 3 Last Power Reading: 217 Wattsv | ||||
|  | ||||
| **Note:** For BMC based compute nodes, turning the PDU outlet power on does not automatically power on the compute side.  Users will need to issue ``rpower <node> on`` to power on the compute side after the BMC boots. | ||||
|  | ||||
|  | ||||
|  | ||||
|   | ||||
		Reference in New Issue
	