mirror of
https://github.com/xcat2/xcat-core.git
synced 2025-06-13 09:50:19 +00:00
Merge pull request #3145 from whowutwut/rinv_firm
Enhancements to rinv code to complete development
This commit is contained in:
@ -28,18 +28,18 @@ BMC/MPA specific:
|
||||
\ **rinv**\ \ *noderange*\ {\ **pci | model | serial | asset | vpd | mprom | deviceid | guid | firm | diag | dimm | bios | mparom | mac | all**\ }
|
||||
|
||||
|
||||
OpenPOWER (using ipmi) server specific:
|
||||
=======================================
|
||||
OpenPOWER (IPMI) server specific:
|
||||
=================================
|
||||
|
||||
|
||||
\ **rinv**\ \ *noderange*\ [\ **model | serial | deviceid | uuid | guid | vpd | mprom | firm | all**\ ]
|
||||
|
||||
|
||||
OpenPOWER (using openbmc) server specific:
|
||||
==========================================
|
||||
OpenPOWER (OpenBMC) server specific:
|
||||
====================================
|
||||
|
||||
|
||||
\ **rinv**\ \ *noderange*\ [\ **model | serial | deviceid | uuid | guid | vpd | mprom | firm | cpu | dimm | all**\ ]
|
||||
\ **rinv**\ \ *noderange*\ [\ **model | serial | firm | cpu | dimm | all**\ ]
|
||||
|
||||
|
||||
PPC (with HMC) specific:
|
||||
@ -195,25 +195,25 @@ Calling \ **rinv**\ for VMware will display the UUID/GUID, number of CPUs, amou
|
||||
|
||||
\ **mprom**\
|
||||
|
||||
Retrieves mprom firmware level
|
||||
Retrieves mprom firmware level.
|
||||
|
||||
|
||||
|
||||
\ **deviceid**\
|
||||
|
||||
Retrieves device identification. Usually device, manufacturing and product ids.
|
||||
Retrieves device identification. Usually device, manufacturing and product IDs.
|
||||
|
||||
|
||||
|
||||
\ **uuid**\
|
||||
|
||||
Retrieves the universally unique identifier
|
||||
Retrieves the universally unique identifier.
|
||||
|
||||
|
||||
|
||||
\ **guid**\
|
||||
|
||||
Retrieves the global unique identifier
|
||||
Retrieves the global unique identifier .
|
||||
|
||||
|
||||
|
||||
|
@ -97,10 +97,10 @@ my %usage = (
|
||||
rinv [-h|--help|-v|--version]
|
||||
BMC specific:
|
||||
rinv <noderange> [mprom|deviceid|uuid|guid|vpd|dimm|all]
|
||||
OpenPOWER (using ipmi) server specific:
|
||||
OpenPOWER (IPMI) server specific:
|
||||
rinv <noderange> [model|serial|deviceid|uuid|guid|vpd|mprom|firm|all]
|
||||
OpenPOWER (using openbmc) server specific:
|
||||
rinv <noderange> [model|serial|deviceid|uuid|guid|vpd|mprom|firm|cpu|dimm|all]
|
||||
OpenPOWER (OpenBMC) server specific:
|
||||
rinv <noderange> [model|serial|firm|cpu|dimm|all]
|
||||
MPA specific:
|
||||
rinv <noderange> [firm|bios|diag|mprom|sprom|mparom|mac|mtm]
|
||||
PPC specific(with HMC):
|
||||
|
@ -10,13 +10,13 @@ B<rinv> [B<-h>|B<--help>|B<-v>|B<--version>]
|
||||
|
||||
B<rinv> I<noderange> {B<pci>|B<model>|B<serial>|B<asset>|B<vpd>|B<mprom>|B<deviceid>|B<guid>|B<firm>|B<diag>|B<dimm>|B<bios>|B<mparom>|B<mac>|B<all>}
|
||||
|
||||
=head2 OpenPOWER (using ipmi) server specific:
|
||||
=head2 OpenPOWER (IPMI) server specific:
|
||||
|
||||
B<rinv> I<noderange> [B<model>|B<serial>|B<deviceid>|B<uuid>|B<guid>|B<vpd>|B<mprom>|B<firm>|B<all>]
|
||||
|
||||
=head2 OpenPOWER (using openbmc) server specific:
|
||||
=head2 OpenPOWER (OpenBMC) server specific:
|
||||
|
||||
B<rinv> I<noderange> [B<model>|B<serial>|B<deviceid>|B<uuid>|B<guid>|B<vpd>|B<mprom>|B<firm>|B<cpu>|B<dimm>|B<all>]
|
||||
B<rinv> I<noderange> [B<model>|B<serial>|B<firm>|B<cpu>|B<dimm>|B<all>]
|
||||
|
||||
=head2 PPC (with HMC) specific:
|
||||
|
||||
@ -125,19 +125,19 @@ Diagnostics information of firmware.
|
||||
|
||||
=item B<mprom>
|
||||
|
||||
Retrieves mprom firmware level
|
||||
Retrieves mprom firmware level.
|
||||
|
||||
=item B<deviceid>
|
||||
|
||||
Retrieves device identification. Usually device, manufacturing and product ids.
|
||||
Retrieves device identification. Usually device, manufacturing and product IDs.
|
||||
|
||||
=item B<uuid>
|
||||
|
||||
Retrieves the universally unique identifier
|
||||
Retrieves the universally unique identifier.
|
||||
|
||||
=item B<guid>
|
||||
|
||||
Retrieves the global unique identifier
|
||||
Retrieves the global unique identifier .
|
||||
|
||||
=item B<all>
|
||||
|
||||
|
@ -416,7 +416,7 @@ sub parse_args {
|
||||
}
|
||||
} elsif ($command eq "rinv") {
|
||||
$subcommand = "all" if (!defined($ARGV[0]));
|
||||
unless ($subcommand =~ /^cpu$|^dimm$|^model$|^serial$|^firm$|^mac$|^vpd$|^mprom$|^deviceid$|^guid$|^uuid$|^all$/) {
|
||||
unless ($subcommand =~ /^model$|^serial$|^firm$|^cpu$|^dimm$|^all$/) {
|
||||
return ([ 1, "Unsupported command: $command $subcommand" ]);
|
||||
}
|
||||
} elsif ($command eq "getopenbmccons") {
|
||||
@ -1018,10 +1018,10 @@ sub rinv_response {
|
||||
|
||||
my $grep_string;
|
||||
if ($node_info{$node}{cur_status} eq "RINV_FIRM_RESPONSE") {
|
||||
$grep_string = "firm";
|
||||
} else {
|
||||
$grep_string = $status_info{RINV_RESPONSE}{argv};
|
||||
}
|
||||
$grep_string = "firm";
|
||||
} else {
|
||||
$grep_string = $status_info{RINV_RESPONSE}{argv};
|
||||
}
|
||||
|
||||
my $src;
|
||||
my $content_info;
|
||||
@ -1031,52 +1031,45 @@ sub rinv_response {
|
||||
my %content = %{ ${ $response_info->{data} }{$key_url} };
|
||||
|
||||
if ($grep_string eq "firm") {
|
||||
# This handles the data from the /xyz/openbmc_project/Software endpoint.
|
||||
#
|
||||
# Handle printing out all posssible Software values in a generic format:
|
||||
# node: <Purpose> Software: <version> (<Activation>)
|
||||
#
|
||||
if (defined($content{Version}) and $content{Version}) {
|
||||
my $firm_ver = "System Firmware Product Version: " . "$content{Version}";
|
||||
xCAT::SvrUtils::sendmsg("$firm_ver", $callback, $node);
|
||||
my $purpose_value = uc ((split(/\./, $content{Purpose}))[-1]);
|
||||
my $activation_value = (split(/\./, $content{Activation}))[-1];
|
||||
#
|
||||
# The space below between "SOFTWARE:" and $content{Version} is intentional
|
||||
# to cause the sorting of this line before any additional info lines
|
||||
#
|
||||
$content_info = "$purpose_value SOFTWARE: $content{Version} ($activation_value)";
|
||||
push (@sorted_output, $content_info);
|
||||
|
||||
if ($content{ExtendedVersion} ne "") {
|
||||
# ExtendedVersion is going to be a comma separated list of additional software
|
||||
my @versions = split(',', $content{ExtendedVersion});
|
||||
foreach my $ver (@versions) {
|
||||
$content_info = "$purpose_value SOFTWARE: -- additional info: $ver";
|
||||
push (@sorted_output, $content_info);
|
||||
}
|
||||
}
|
||||
next;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
if (! defined $content{Present}) {
|
||||
# This should never happen, but if we find this, contact firmware team to fix...
|
||||
xCAT::SvrUtils::sendmsg("ERROR: Invalid data for $key_url, contact firmware team!", $callback, $node);
|
||||
next;
|
||||
}
|
||||
|
||||
if (($grep_string eq "vpd" or $grep_string eq "model") and $key_url =~ /\/motherboard$/) {
|
||||
my $partnumber = "BOARD Part Number: " . "$content{PartNumber}";
|
||||
xCAT::SvrUtils::sendmsg("$partnumber", $callback, $node);
|
||||
next if ($grep_string eq "model");
|
||||
}
|
||||
# SPECIAL CASE: If 'serial' or 'model' is specified, only return the system level information
|
||||
if ($grep_string eq "serial" or $grep_string eq "model") {
|
||||
if ($key_url ne "$openbmc_project_url/inventory/system") {
|
||||
next;
|
||||
}
|
||||
}
|
||||
|
||||
if (($grep_string eq "vpd" or $grep_string eq "serial") and $key_url =~ /\/motherboard$/) {
|
||||
my $serialnumber = "BOARD Serial Number: " . "$content{SerialNumber}";
|
||||
xCAT::SvrUtils::sendmsg("$serialnumber", $callback, $node);
|
||||
next if ($grep_string eq "serial");
|
||||
}
|
||||
|
||||
if (($grep_string eq "vpd" or $grep_string eq "mprom") and $key_url =~ /\/motherboard$/) {
|
||||
xCAT::SvrUtils::sendmsg("No mprom information is available", $callback, $node);
|
||||
next if ($grep_string eq "mprom");
|
||||
}
|
||||
|
||||
if (($grep_string eq "vpd" or $grep_string eq "deviceid") and $key_url =~ /\/motherboard$/) {
|
||||
xCAT::SvrUtils::sendmsg("No deviceid information is available", $callback, $node);
|
||||
next if ($grep_string eq "deviceid");
|
||||
}
|
||||
|
||||
if ($grep_string eq "uuid") {
|
||||
xCAT::SvrUtils::sendmsg("No uuid information is available", $callback, $node);
|
||||
last;
|
||||
}
|
||||
|
||||
if ($grep_string eq "guid") {
|
||||
xCAT::SvrUtils::sendmsg("No guid information is available", $callback, $node);
|
||||
last;
|
||||
}
|
||||
|
||||
if ($grep_string eq "mac" and $key_url =~ /\/ethernet/) {
|
||||
my $macaddress = "MAC: " . $content{MACAddress};
|
||||
xCAT::SvrUtils::sendmsg("$macaddress", $callback, $node);
|
||||
next;
|
||||
}
|
||||
|
||||
if ($grep_string eq "all" or $key_url =~ /\/$grep_string/) {
|
||||
if ($key_url =~ /\/(cpu\d*)\/(\w+)/) {
|
||||
$src = "$1 $2";
|
||||
} else {
|
||||
@ -1084,17 +1077,25 @@ sub rinv_response {
|
||||
}
|
||||
|
||||
foreach my $key (keys %content) {
|
||||
# If not all options is specified, check whether the key string contains
|
||||
# the keyword option. If so, add it to the return data
|
||||
if ($grep_string ne "all" and ((lc($key) !~ m/$grep_string/i) and ($key_url !~ m/$grep_string/i)) ) {
|
||||
next;
|
||||
}
|
||||
$content_info = uc ($src) . " " . $key . " : " . $content{$key};
|
||||
push (@sorted_output, $node . ": ". $content_info); #Save output in array
|
||||
push (@sorted_output, $content_info); #Save output in array
|
||||
}
|
||||
}
|
||||
}
|
||||
# If sorted array has any contents, sort it and print it
|
||||
if (scalar @sorted_output > 0) {
|
||||
@sorted_output = sort @sorted_output; #Sort all output
|
||||
my $result = join "\n", @sorted_output; #Join into a single string for easier display
|
||||
xCAT::SvrUtils::sendmsg("$result", $callback);
|
||||
}
|
||||
}
|
||||
# If sorted array has any contents, sort it and print it
|
||||
if (scalar @sorted_output > 0) {
|
||||
# sort alpha, then numeric
|
||||
my @sorted_output = grep {s/(^|\D)0+(\d)/$1$2/g,1} sort
|
||||
grep {s/(\d+)/sprintf"%06.6d",$1/ge,1} @sorted_output;
|
||||
xCAT::SvrUtils::sendmsg("$_", $callback, $node) foreach (@sorted_output);
|
||||
} else {
|
||||
xCAT::SvrUtils::sendmsg("$::NO_ATTRIBUTES_RETURNED", $callback, $node);
|
||||
}
|
||||
|
||||
if ($next_status{ $node_info{$node}{cur_status} }) {
|
||||
$node_info{$node}{cur_status} = $next_status{ $node_info{$node}{cur_status} };
|
||||
|
Reference in New Issue