mirror of
https://github.com/xcat2/confluent.git
synced 2026-08-27 17:16:42 +00:00
acd6bb228c
Each is the only thing keeping its rule group from being selectable whole. userutil.py imported ctypes with a star; the names it uses are POINTER, byref, c_char_p, c_int, c_int32, c_uint and cdll. The oem lookup loop had an else with no break, so the else always ran. The alert parameter table wrapped int in a lambda that only forwards to it. And the watchdog interval passed 0 where os.environ.get documents a string, which worked because int(0) is 0.