=head1 B<NAME>
|
|
|
|
B<renergy> - remote energy management tool
|
|
|
|
|
|
=head1 B<SYNOPSIS>
|
|
|
|
B<renergy> [-h | --help]
|
|
|
|
B<renergy> [-v | --version]
|
|
|
|
|
|
B<Power 6 server specific :>
|
|
|
|
=over 2
|
|
|
|
B<renergy> I<noderange> [-V] { all | { [savingstatus] [cappingstatus]
|
|
[cappingmaxmin] [cappingvalue] [cappingsoftmin] [averageAC]
|
|
[averageDC] [ambienttemp] [exhausttemp] [CPUspeed] } }
|
|
|
|
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
|
|
| {cappingstatus}={on | off} | {cappingwatt}=watt
|
|
| {cappingperc}=percentage }
|
|
|
|
=back
|
|
|
|
B<Power 7 server specific :>
|
|
|
|
=over 2
|
|
|
|
B<renergy> I<noderange> [-V] { all | { [savingstatus] [dsavingstatus]
|
|
[cappingstatus] [cappingmaxmin] [cappingvalue] [cappingsoftmin]
|
|
[averageAC] [averageDC] [ambienttemp] [exhausttemp] [CPUspeed]
|
|
[syssbpower] [sysIPLtime] } }
|
|
|
|
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
|
|
| {dsavingstatus}={on-norm | on-maxp | off}
|
|
| {cappingstatus}={on | off} | {cappingwatt}=watt
|
|
| {cappingperc}=percentage }
|
|
|
|
=back
|
|
|
|
B<Blade specific :>
|
|
|
|
=over 2
|
|
|
|
B<For node of blade management module:>
|
|
|
|
=over 4
|
|
|
|
B<renergy> I<noderange> [-V] { all | pd1all | pd2all | { [pd1status]
|
|
[pd2status] [pd1policy] [pd2policy] [pd1powermodule1]
|
|
[pd1powermodule2] [pd2powermodule1] [pd2powermodule2]
|
|
[pd1avaiablepower] [pd2avaiablepower] [pd1reservedpower]
|
|
[pd2reservedpower] [pd1remainpower] [pd2remainpower]
|
|
[pd1inusedpower] [pd2inusedpower] [availableDC] [averageAC]
|
|
[thermaloutput] [ambienttemp] [mmtemp] } }
|
|
|
|
=back
|
|
|
|
B<For node of blade server:>
|
|
|
|
=over 4
|
|
|
|
B<renergy> I<noderange> [-V] { all | { [averageAC]
|
|
[capability] [cappingvalue] [CPUspeed] [maxCPUspeed]
|
|
[savingstatus] [dsavingstatus] } }
|
|
|
|
B<renergy> I<noderange> [-V] { {savingstatus}={on | off}
|
|
| {dsavingstatus}={on-norm | on-maxp | off} }
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
=head1 B<DESCRIPTION>
|
|
|
|
This B<renergy> command can be used to manage the energy consumption of
|
|
IBM servers which support IBM EnergyScale technology. Through this command,
|
|
user can query and set the power saving and power capping status, also can
|
|
query the average consumed energy, the ambient and exhaust temperature,
|
|
the processor frequency for a server.
|
|
|
|
B<renergy> command supports IBM POWER6 and POWER7 rack-mounted servers
|
|
(system P CEC node), blade management module node, blade server node.
|
|
For rack-mounted servers, following specific hardware types are supported:
|
|
I<8203-E4A>, I<8204-E8A>, I<9125-F2A>, I<8233-E8B>, I<8236-E8C>.
|
|
|
|
The parameter I<noderange> needs to be specified for B<renergy> command to
|
|
get the target server. The I<noderange> should be a list of CEC node names, blade
|
|
management module node names or blade server node names. Lpar name
|
|
is not acceptable here.
|
|
|
|
B<renergy> command can accept multiple of energy attributes to query or one of energy
|
|
attribute to set. If only the attribute name is specified, without the '=', B<renergy>
|
|
gets and displays the current value. Otherwise, if specifying the attribute with '=' like
|
|
'savingstatus=on', B<renergy> will set the attribute savingstatus to value 'on'.
|
|
|
|
The attributes listed in the B<SYNOPSIS> section are which ones can be handled by
|
|
B<renergy> command. But for each specific type of server, there are some attributes that
|
|
are not supported. If user specifies an attribute which does not be supported by certain
|
|
server, the return value of this attribute will be 'na'.
|
|
|
|
The supported attributes for each specific hardware types are listed as follow:
|
|
|
|
=over 2
|
|
|
|
B<8203-E4A>, B<8204-E8A>
|
|
|
|
=over 4
|
|
|
|
Supported attributes:
|
|
|
|
B<Query>: savingstatus,cappingstatus,cappingmin,cappingmax,
|
|
cappingvalue,cappingsoftmin,averageAC,averageDC,ambienttemp,
|
|
exhausttemp,CPUspeed
|
|
|
|
B<Set>: savingstatus,cappingstatus,cappingwatt,cappingperc
|
|
|
|
=back
|
|
|
|
B<9125-F2A>
|
|
|
|
=over 4
|
|
|
|
Supported attributes:
|
|
|
|
B<Query>: savingstatus,averageAC,ambienttemp,exhausttemp,
|
|
CPUspeed
|
|
|
|
B<Set>: savingstatus
|
|
|
|
=back
|
|
|
|
B<8233-E8B>, B<8236-E8C>
|
|
|
|
=over 4
|
|
|
|
Supported attributes:
|
|
|
|
B<Query>: savingstatus,dsavingstatus,cappingstatus,cappingmin,
|
|
cappingmax,cappingvalue,cappingsoftmin,averageAC,averageDC,
|
|
ambienttemp,exhausttemp,CPUspeed,syssbpower,sysIPLtime
|
|
|
|
B<Set>: savingstatus,dsavingstatus,cappingstatus,cappingwatt,
|
|
cappingperc
|
|
|
|
=back
|
|
|
|
=back
|
|
|
|
Note:
|
|
For system P CEC nodes, each query operation for attribute CPUspeed, averageAC
|
|
or averageDC needs about 30 seconds to complete. The query for others attributes
|
|
will get response immediately.
|
|
|
|
|
|
=head1 B<PREREQUISITE>
|
|
|
|
For the system P CEC nodes, B<renergy> command depends
|
|
on the Energy Management Plugin for xCAT B<xCAT-cimclient> to
|
|
communicate with server. Then, before running the B<renergy> command, to
|
|
check whether the B<xCAT-cimclient> package has been installed.
|
|
|
|
B<xCAT-cimclient> can be downloaded from IBM web site:
|
|
http://www14.software.ibm.com/webapp/set2/sas/f/xcat/energy.html
|
|
|
|
|
|
=head1 B<OPTIONS>
|
|
|
|
=over 4
|
|
|
|
=item B<-h | --help>
|
|
|
|
Display the usage message.
|
|
|
|
=item B<-v | --version>
|
|
|
|
Display the version information.
|
|
|
|
=item B<-V>
|
|
|
|
Verbose output.
|
|
|
|
|
|
=item B<all>
|
|
|
|
Query all energy attributes which supported by the specific
|
|
type of hardware.
|
|
|
|
=item B<pd1all>
|
|
|
|
Query all energy attributes of the power domain 1 for blade
|
|
management module node.
|
|
|
|
=item B<pd2all>
|
|
|
|
Query all energy attributes of the power domain 2 for blade
|
|
management module node.
|
|
|
|
=item B<ambienttemp>
|
|
|
|
Query the current ambient temperature. (Unit is centigrade)
|
|
|
|
=item B<availableDC>
|
|
|
|
Query the total DC power available for the entire blade center chassis.
|
|
|
|
=item B<averageAC>
|
|
|
|
Query the average power consumed (Input). (Unit is watt)
|
|
|
|
Note: For 9125-F2A server, the value of attribute
|
|
averageAC is the aggregate for all of the servers in a rack.
|
|
|
|
Note: For Blade Center, the value of attribute
|
|
averageAC is the total AC power being consumed by all modules
|
|
in the chassis. It also includes power consumed by the Chassis
|
|
Cooling Devices for BCH chassis.
|
|
|
|
=item B<averageDC>
|
|
|
|
Query the average power consumed (Output). (Unit is watt)
|
|
|
|
=item B<capability>
|
|
|
|
Query the Power Capabilities of the blade server.
|
|
|
|
staticPowerManagement: the module with the static worst case power values.
|
|
|
|
fixedPowermanagement: the module with the static power values but ability
|
|
to throttle.
|
|
|
|
dynamicPowerManagement: the module with power meter capability, measurement
|
|
enabled, but capping disabled.
|
|
|
|
dynamicPowerMeasurement1: the module with power meter capability, measurement
|
|
enabled, phase 1 only
|
|
|
|
dynamicPowerMeasurement2: the module with power meter capability, measurement
|
|
enabled, phase 2 or higher
|
|
|
|
dynamicPowerMeasurementWithPowerCapping: the module with power meter capability,
|
|
both measurement and capping enabled, phase 2 or higher
|
|
|
|
=item B<cappingmaxmin>
|
|
|
|
Query the maximum and minimum of power capping value
|
|
which can be set for a CEC or blade server. (Unit is watt)
|
|
|
|
=item B<cappingperc>=B<percentage>
|
|
|
|
Set the power capping value base on the percentage of
|
|
the max-min of capping value which getting from
|
|
I<cappingmaxmim> attribute. The valid value must be
|
|
from 0 to 100.
|
|
|
|
=item B<cappingsoftmin>
|
|
|
|
Query the minimum value that can be assigned to power
|
|
capping without guaranteed enforceability. (Unit is watt)
|
|
|
|
=item B<cappingstatus>
|
|
|
|
Query the power capping status. The result should be 'on'
|
|
or 'off'.
|
|
|
|
=item B<cappingstatus>={B<on> | B<off>}
|
|
|
|
Set the power capping status. The value must be 'on'
|
|
or 'off'. This is the switch to turn on or turn off the
|
|
power capping function.
|
|
|
|
=item B<cappingvalue>
|
|
|
|
Query the current power capping value. (Unit is watt)
|
|
|
|
=item B<cappingwatt>=B<watt>
|
|
|
|
Set the power capping value base on the watt unit.
|
|
|
|
If the 'watt' > maximum of I<cappingmaxmin> or 'watt'
|
|
< minimum of I<cappingmaxmim>, the setting operation
|
|
will be failed.
|
|
|
|
=item B<CPUspeed>
|
|
|
|
Query the effective processor frequency. (Unit is MHz)
|
|
|
|
=item B<dsavingstatus>
|
|
|
|
Query the dynamic power saving status. The result should
|
|
be 'on-norm', 'on-maxp' or 'off'.
|
|
|
|
If turning on the dynamic power saving, the processor
|
|
frequency and voltage will be dropped dynamically based on
|
|
the core utilization. It supports two modes for turn on state:
|
|
|
|
I<on-norm> - means normal, the processor frequency cannot
|
|
exceed the nominal value;
|
|
|
|
I<on-maxp> - means maximum performance, the processor
|
|
frequency can exceed the nominal value.
|
|
|
|
=item B<dsavingstatus>={B<on-norm> | B<on-maxp> | B<off>}
|
|
|
|
Set the dynamic power saving. The value must be 'on-norm',
|
|
'on-maxp' or 'off'.
|
|
|
|
The dsavingstatus setting operation needs about 2 minutes
|
|
to take effect. (The used time depends on the hardware type)
|
|
|
|
The B<dsavingstatus> only can be turned on when the
|
|
B<savingstatus> is in turn off status.
|
|
|
|
=item B<exhausttemp>
|
|
|
|
Query the current exhaust temperature. (Unit is centigrade)
|
|
|
|
=item B<maxCPUspeed>
|
|
|
|
Query the maximum processor frequency. (Unit is MHz)
|
|
|
|
=item B<mmtemp>
|
|
|
|
Query the current temperature of management module.
|
|
(Unit is centigrade)
|
|
|
|
=item B<pd1status>
|
|
|
|
Query the status of power domain 1 for blade management
|
|
module node.
|
|
|
|
=item B<pd1policy>
|
|
|
|
Query the power management policy of power domain 1.
|
|
|
|
=item B<pd1powermodule1>
|
|
|
|
Query the First Power Module capacity in power domain 1.
|
|
|
|
=item B<pd1powermodule2>
|
|
|
|
Query the Second Power Module capacity in power domain 1.
|
|
|
|
=item B<pd1avaiablepower>
|
|
|
|
Query the total available power in power domain 1.
|
|
|
|
=item B<pd1reservedpower>
|
|
|
|
Query the power that has been reserved for power domain 1.
|
|
|
|
=item B<pd1remainpower>
|
|
|
|
Query the remaining power available in power domain 1.
|
|
|
|
=item B<pd1inusedpower>
|
|
|
|
Query the total power being used in power domain 1.
|
|
|
|
=item B<pd2status>
|
|
|
|
Query the status of power domain 2 for blade management
|
|
module node.
|
|
|
|
=item B<pd2policy>
|
|
|
|
Query the power management policy of power domain 2.
|
|
|
|
=item B<pd2powermodule1>
|
|
|
|
Query the First Power Module capacity in power domain 2.
|
|
|
|
=item B<pd2powermodule2>
|
|
|
|
Query the Second Power Module capacity in power domain 2.
|
|
|
|
=item B<pd2avaiablepower>
|
|
|
|
Query the total available power in power domain 2.
|
|
|
|
=item B<pd2reservedpower>
|
|
|
|
Query the power that has been reserved for power domain 2.
|
|
|
|
=item B<pd2remainpower>
|
|
|
|
Query the remaining power available in power domain 2.
|
|
|
|
=item B<pd2inusedpower>
|
|
|
|
Query the total power being used in power domain 2.
|
|
|
|
=item B<savingstatus>
|
|
|
|
Query the static power saving status. The result should be
|
|
'on' or 'off'. 'on' - enable; 'off' - disable.
|
|
|
|
=item B<savingstatus>={B<on> | B<off>}
|
|
|
|
Set the static power saving. The value must be 'on' or 'off'.
|
|
|
|
If turning on the static power saving, the processor frequency
|
|
and voltage will be dropped to a fixed value to save energy.
|
|
|
|
The savingstatus setting operation needs about 2 minutes to
|
|
take effect. (The used time depends on the hardware type)
|
|
|
|
The B<savingstatus> only can be turned on when the
|
|
B<dsavingstatus> is in turn off status.
|
|
|
|
=item B<sysIPLtime>
|
|
|
|
Query the time used from FSP standby to OS standby.
|
|
(Unit is Second)
|
|
|
|
=item B<syssbpower>
|
|
|
|
Query the system power consumed prior to power on.
|
|
(Unit is MHz)
|
|
|
|
=item B<thermaloutput>
|
|
|
|
Query the thermal output (load) in BTUs per hour for the blade
|
|
center chassis.
|
|
|
|
=back
|
|
|
|
|
|
=head1 B<RETURN VALUE>
|
|
|
|
0 The command completed successfully.
|
|
|
|
1 An error has occurred.
|
|
|
|
|
|
=head1 B<EXAMPLES>
|
|
|
|
=over 3
|
|
|
|
=item 1
|
|
|
|
Query all the attributes which CEC1,CEC2 supported.
|
|
|
|
B<renergy> CEC1,CEC2 all
|
|
|
|
The output of the query operation:
|
|
|
|
CEC1: savingstatus: off
|
|
CEC1: dsavingstatus: off
|
|
CEC1: cappingstatus: off
|
|
CEC1: cappingmin: 1953 W
|
|
CEC1: cappingmax: 2358 W
|
|
CEC1: cappingvalue: 2000 W
|
|
CEC1: cappingsoftmin: 304 W
|
|
CEC1: averageAC: na
|
|
CEC1: averageDC: na
|
|
CEC1: ambienttemp: na
|
|
CEC1: exhausttemp: na
|
|
CEC1: CPUspeed: na
|
|
CEC1: syssbpower: 40 W
|
|
CEC1: sysIPLtime: 900 S
|
|
CEC2: savingstatus: off
|
|
CEC2: cappingstatus: off
|
|
CEC2: cappingmin: 955 W
|
|
CEC2: cappingmax: 1093 W
|
|
CEC2: cappingvalue: 1000 W
|
|
CEC2: cappingsoftmin: 226 W
|
|
CEC2: averageAC: 627 W
|
|
CEC2: averageDC: 531 W
|
|
CEC2: ambienttemp: 25 C
|
|
CEC2: exhausttemp: 40 C
|
|
CEC2: CPUspeed: 4695 MHz
|
|
|
|
=item 2
|
|
|
|
Query all the attirbutes for management module node MM1. (For chassis)
|
|
|
|
B<renergy> MM1 all
|
|
|
|
The output of the query operation:
|
|
|
|
mm1: availableDC: 5880W
|
|
mm1: frontpaneltmp: 18.00 Centigrade
|
|
mm1: inusedAC: 2848W
|
|
mm1: mmtmp: 28.00 Centigrade
|
|
mm1: pd1avaiablepower: 2940W
|
|
mm1: pd1inusedpower: 848W
|
|
mm1: pd1policy: redundantWithoutPerformanceImpact
|
|
mm1: pd1powermodule1: Bay 1: 2940W
|
|
mm1: pd1powermodule2: Bay 2: 2940W
|
|
mm1: pd1remainpower: 1269W
|
|
mm1: pd1reservedpower: 1671W
|
|
mm1: pd1status: 1 - Power domain status is good.
|
|
mm1: pd2avaiablepower: 2940W
|
|
mm1: pd2inusedpower: 1490W
|
|
mm1: pd2policy: redundantWithoutPerformanceImpact
|
|
mm1: pd2powermodule1: Bay 3: 2940W
|
|
mm1: pd2powermodule2: Bay 4: 2940W
|
|
mm1: pd2remainpower: 51W
|
|
mm1: pd2reservedpower: 2889W
|
|
mm1: pd2status: 2 - Warning: Power redundancy does not exist
|
|
in this power domain.
|
|
mm1: thermaloutput: 9717.376000 BTU/hour
|
|
|
|
=item 3
|
|
|
|
Query all the attirbutes for blade server node blade1.
|
|
|
|
B<renergy> blade1 all
|
|
|
|
The output of the query operation:
|
|
|
|
blade1: CPUspeed: 4204MHZ
|
|
blade1: averageDC: 227W
|
|
blade1: capability: dynamicPowerMeasurement2
|
|
blade1: cappingvalue: 315W
|
|
blade1: dsavingstatus: off
|
|
blade1: maxCPUspeed: 4204MHZ
|
|
blade1: savingstatus: off
|
|
|
|
=item 4
|
|
|
|
Query the attributes savingstatus, cappingstatus
|
|
and CPUspeed for server CEC1.
|
|
|
|
B<renergy> CEC1 savingstatus cappingstatus CPUspeed
|
|
|
|
The output of the query operation:
|
|
|
|
CEC1: savingstatus: off
|
|
CEC1: cappingstatus: on
|
|
CEC1: CPUspeed: 3621 MHz
|
|
|
|
=item 5
|
|
|
|
Turn on the power saving function of CEC1.
|
|
|
|
B<renergy> CEC1 savingstatus=on
|
|
|
|
The output of the setting operation:
|
|
|
|
CEC1: Set savingstatus succeeded.
|
|
CEC1: This setting may need some minutes to take effect.
|
|
|
|
=item 6
|
|
|
|
Set the power capping value base on the percentage of the
|
|
max-min capping value. Here, set it to 50%.
|
|
|
|
B<renergy> CEC1 cappingperc=50
|
|
|
|
If the maximum capping value of the CEC1 is 850w, and the
|
|
minimum capping value of the CEC1 is 782w, the Power Capping
|
|
value will be set as ((850-782)*50% + 782) = 816w.
|
|
|
|
The output of the setting operation:
|
|
|
|
CEC1: Set cappingperc succeeded.
|
|
CEC1: cappingvalue: 816
|
|
|
|
=back
|
|
|
|
|
|
=head1 B<REFERENCES>
|
|
|
|
=over 3
|
|
|
|
=item 1
|
|
|
|
The more information of 'Power System Energy Management':
|
|
|
|
http://www-03.ibm.com/systems/power/software/energy/index.html
|
|
|
|
=item 2
|
|
|
|
EnergyScale white paper for Power6:
|
|
|
|
http://www-03.ibm.com/systems/power/hardware/whitepapers/energyscale.html
|
|
|
|
=item 3
|
|
|
|
EnergyScale white paper for Power7:
|
|
|
|
http://www-03.ibm.com/systems/power/hardware/whitepapers/energyscale7.html
|
|
|
|
=back
|
|
|
|
=head1 B<FILES>
|
|
|
|
/opt/xcat/bin/renergy
|
|
|
|
|