xcat-core/perl-xCAT/xCAT/PPCenergy.pm
2012-05-02 06:23:43 +00:00

371 lines
11 KiB
Perl

# IBM(c) 2009 EPL license http://www.eclipse.org/legal/epl-v10.html
package xCAT::PPCenergy;
use strict;
use Getopt::Long;
use xCAT::Usage;
use xCAT::NodeRange;
use xCAT::DBobjUtils;
%::QUERY_ATTRS = (
'savingstatus' => 1,
'dsavingstatus' => 1,
'cappingstatus' => 1,
'cappingmaxmin' => 1,
'cappingvalue' => 1,
'cappingsoftmin' => 1,
'averageAC' => 1,
'averageDC' => 1,
'ambienttemp' => 1,
'exhausttemp' => 1,
'CPUspeed' => 1,
'syssbpower' => 1,
'sysIPLtime' => 1,
# for FFO, only supported when communicating to fsp directly
'ffoMin' => 1,
'ffoVmin' => 1,
'ffoTurbo' => 1,
'ffoNorm' => 1,
'fsavingstatus' => 1,
'ffovalue' => 1,
);
%::SET_ATTRS = (
'savingstatus' => 1,
'dsavingstatus' => 1,
'cappingstatus' => 1,
'cappingwatt' => 1,
'cappingperc' => 1,
# for FFO
'fsavingstatus' => 1,
'ffovalue' => 1,
);
$::CIM_CLIENT_PATH = "$::XCATROOT/sbin/xCAT_cim_client";
# Parse the arguments of the command line for renergy command
sub parse_args {
my $request = shift;
my %opt = ();
my $cmd = $request->{command};
my $args = $request->{arg};
my $nodes = $request->{node};
my $query_attrs = (); # The attributes list for query operation
my $set_pair = (); # The attribute need to be set. e.g. savingstatus=on
my $set_flag = (); # Indicate there's setting param in the argv
my $argv_flag = (); # Indicate there's param in the argv
my @notfspnodes = (); # The nodes list which are not fsp
# set the usage subroutine
local *usage = sub {
my $usage_string = xCAT::Usage->getUsage($cmd);
return( [ $_[0], $usage_string ] );
};
if ($request->{arg}) {
@ARGV = @{$request->{arg}};
$Getopt::Long::ignorecase = 0;
Getopt::Long::Configure( "bundling" );
if ($nodes) {
if (!GetOptions( 'V' => \$::VERBOSE )) {
return (&usage());
}
if ($::VERBOSE) {
$opt{verbose} = 1;
}
if ($#ARGV < 0) {
return (&usage());
}
# Check the validity of the parameters of Query and Set
foreach my $attr (@ARGV) {
my ($set_attr, $set_value) = split (/=/, $attr);
if (defined($set_value)) {
if ($argv_flag) {
return (&usage());
}
if ($::SET_ATTRS{$set_attr} != 1) {
return (&usage());
}
if (($set_attr eq "savingstatus" || $set_attr eq "fsavingstatus")
&& ($set_value ne "on" && $set_value ne "off")) {
return (&usage());
} elsif ($set_attr eq "dsavingstatus"
&& ($set_value ne "off"
&& $set_value ne "on-norm" && $set_value ne "on-maxp")) {
return (&usage());
} elsif ($set_attr eq "cappingstatus"
&& ($set_value ne "on" && $set_value ne "off")) {
return (&usage());
} elsif ( ($set_attr eq "cappingwatt"
|| $set_attr eq "cappingperc" || $set_attr eq "ffovalue")
&& $set_value =~ /\D/) {
return (&usage());
}
$set_pair = $set_attr."=".$set_value;
$set_flag = 1;
} else {
if ($set_flag) {
return (&usage());
}
}
$argv_flag = 1;
}
if (!$set_flag) {
my @query_list = @ARGV;
if ($query_list[0] eq "all" and $#query_list == 0) {
$query_attrs = "all";
} else {
my @no_dup_query_list = ();
foreach my $q_attr (@query_list) {
chomp($q_attr);
if ($::QUERY_ATTRS{$q_attr} != 1) {
return (&usage());
}
if (!grep (/^$q_attr$/, @no_dup_query_list)) {
push @no_dup_query_list, $q_attr;
}
}
$query_attrs = join (',', @no_dup_query_list);
}
}
} else {
# If has not nodes, the -h or -v option must be input
if (!GetOptions( 'h|help' => \$::HELP,
'v|version' => \$::VERSION)) {
return (&usage());
}
if (! ($::HELP || $::VERSION) ) {
return (&usage());
}
if ($::HELP) {
return (&usage());
}
if ($::VERSION) {
my $version_string = xCAT::Usage->getVersion('renergy');
return( [ $_[0], $version_string] );
}
if (scalar(@ARGV)) {
return (&usage());
}
}
} else {
return (&usage());
}
# Check whether the hardware type of nodes are fsp or cec
#my $nodetype_tb = xCAT::Table->new('nodetype');
#unless ($nodetype_tb) {
# return ([undef, "Error: Cannot open the nodetype table"]);
#}
#my $nodetype_v = $nodetype_tb->getNodesAttribs($nodes, ['nodetype']);
my $nodetyperef = xCAT::DBobjUtils->getnodetype($nodes, "ppc");
my $i = 0;
foreach my $node (@{$nodes}) {
if ($$nodetyperef{$node} ne 'fsp' &&
$$nodetyperef{$node} ne 'cec') {
push @notfspnodes, $node;
}
$i++;
}
#$nodetype_tb->close();
if (@notfspnodes) {
return ([undef, "Error: The hardware type of following nodes are not fsp or cec: ".join(',', @notfspnodes)]);
}
if ($query_attrs) {
$opt{'query'} = $query_attrs;
} elsif ($set_pair) {
$opt{'set'} = $set_pair;
}
$request->{method} = $cmd;
return (\%opt);
}
# Handle the energy query and setting work
sub renergy {
my $request = shift;
my $hcphost = shift;
my $nodehash = shift;
my @return_msg = ();
my $opt = $request->{'opt'};
my $verbose = $opt->{'verbose'};
# Get the CEC
my ($node, $attrs) = %$nodehash;
my $cec_name = @$attrs[2];
my $hw_type = @$attrs[4];
if (!$cec_name) {
return ([[$node, "ERROR: Cannot find the cec name, check the attributes: vpd.serial, vpd.mtm.", 1]]);
}
# Check the existence of cim client
if ( (! -f $::CIM_CLIENT_PATH)
|| (! -x $::CIM_CLIENT_PATH) ) {
return ([[$node, "ERROR: Cannot find the Energy Management Plugin for xCAT [$::CIM_CLIENT_PATH] or it's NOT executable. Please install the xCAT-cimclient package correctly. Get more information from man page of renergy command.", 1]]);
}
my $verb_arg = "";
if ($verbose) {
$verb_arg = "-V";
}
# get the user and passwd for hcp: hmc, fsp, cec
my $hcp_type = xCAT::DBobjUtils->getnodetype($hcphost, "ppc");
my $user;
my $password;
if ($hcp_type eq "hmc") {
($user, $password) = xCAT::PPCdb::credentials($hcphost, $hcp_type);
} else {
($user, $password) = xCAT::PPCdb::credentials($hcphost, $hcp_type,'HMC');
}
my $fsps; #The node of fsp that belong to the cec
my @hcps_ip;
if ($hcp_type ne "hmc" && $hw_type eq "cec") {
$fsps = xCAT::DBobjUtils->getchildren($node);
if( !defined($fsps) ) {
return ([[$node, "Failed to get the FSPs for the cec $hcphost.", -1]]);
}
#my $hcp_ip = xCAT::Utils::getNodeIPaddress($hcphost);
my $hcp_ip = xCAT::FSPUtils::getIPaddress($request, $hw_type, $hcphost);
if (!defined($hcp_ip) or ($hcp_ip == -3)) {
return ([[$node, "Failed to get IP address for $hcphost.", -1]]);
}
push @hcps_ip, split(',', $hcp_ip);
my $fsp_node = $$fsps[0];
($user, $password) = xCAT::PPCdb::credentials( $fsp_node, "fsp",'HMC');
if ( !$password) {
return ([[$node, "Cannot get password of userid 'HMC'. Please check table 'ppchcp' or 'ppcdirect'.", -1]]);
}
} else {
# for the case that hcp is hmc or fsp
push @hcps_ip, xCAT::Utils::getNodeIPaddress($hcphost);
}
if (!$user || !$password) {
return ([[$node, "Cannot get user:password for the node. Please check table 'ppchcp' or 'ppcdirect'.", -1]]);
}
# secure passwd in verbose mode
my $tmpv = $verbose;
$verbose = 0;
if ($verbose) {
push @return_msg, [$node, "Attributes of $node:\n User=$user\n Password=$password\n CEC=$cec_name\n nodetype=$hw_type\n inithcp=$hcphost\n hcps=@hcps_ip\n hcptype=$hcp_type", 0];
}
$verbose = $tmpv;
my $master = xCAT::Utils->get_site_Master();
my $masterip = xCAT::NetworkUtils->getipaddr($master);
if ($masterip =~ /:/) { #IPv6, needs fping6 support
if (!-x '/usr/bin/fping6')
{
push @return_msg, [$node, "fping6 is not availabe for IPv6 ping.", -1];
return \@return_msg;
}
open (FPING, "fping6 ".join(' ',@hcps_ip). " 2>&1 |") or die("Cannot open fping pipe: $!");
} else {
open (FPING, "fping ".join(' ',@hcps_ip). " 2>&1 |") or die("Cannot open fping pipe: $!");
}
my @pingable_hcp;
while (<FPING>) {
if ($verbose) {
push @return_msg, [$node, $_, 0];
}
if ($_ =~ /is alive/) {
s/ is alive//;
push @pingable_hcp, $_;
}
}
if (!@pingable_hcp) {
push @return_msg, [$node, "No hcp can be pinged.", -1];
return \@return_msg;
}
# try the ip of hcp one by one
my @lastnoerr_msg;
my @noerr_msg;
my @last_msg;
foreach my $hcp (@pingable_hcp) {
push @noerr_msg, @lastnoerr_msg;
@lastnoerr_msg = ();
@last_msg = ();
# Generate the url path for CIM communication
chomp($hcp);
my $url_path = "https://"."$user".":"."$password"."\@"."$hcp".":5989";
# Execute the request
my $cmd = "";
if ($opt->{'set'}) {
$cmd = "$::CIM_CLIENT_PATH $verb_arg -u $url_path -n $cec_name -o $opt->{'set'}";
} elsif ($opt->{'query'}) {
$cmd = "$::CIM_CLIENT_PATH $verb_arg -u $url_path -n $cec_name -o $opt->{'query'}";
}
if ($verbose) {
push @noerr_msg, [$node, "Run following command: $cmd", 0];
}
# Disable the CHID signal before run the command. Otherwise the
# $? value of `$cmd` will come from handler of CHID signal
$SIG{CHLD} = 'DEFAULT';
# Call the xCAT_cim_client to query or set the energy capabilities
$cmd .= " 2>&1";
# secure passwd in verbose mode
my $tmpv = $::VERBOSE;
$::VERBOSE = 0;
my @result = xCAT::Utils->runcmd("$cmd", -1);
$::VERBOSE = $tmpv;
foreach my $line (@result) {
chomp($line);
if ($line =~ /^\s*$/) {
next;
}
push @lastnoerr_msg, [$node, $line, 0];
push @last_msg, [$node, $line, $::RUNCMD_RC];
}
if (!$::RUNCMD_RC) {
last;
}
}
# only display the correct msg when getting correct result from one fsp
if ($::RUNCMD_RC || $verbose) {
push @return_msg, @noerr_msg;
}
push @return_msg, @last_msg;
return \@return_msg;
}
1;