xcat-core/xCAT-client/pods/man1/rmhwconn.1.pod
2010-12-20 07:15:23 +00:00

96 lines
1.8 KiB
Plaintext

=head1 NAME
B<rmhwconn> - Use this command to remove connections from FSP and BPA nodes to HMC nodes.
=head1 SYNOPSIS
B<rmhwconn> [B<-h>| B<--help>]
B<rmhwconn> [B<-v>| B<--version>]
=head2 PPC (with HMC) specific:
B<rmhwconn> [B<-V>| B<--verbose>] noderange
=head2 PPC (without HMC, using FSPAPI) specific:
B<rmhwconn> noderange B<-T tooltype>
=head1 DESCRIPTION
For PPC (with HMC) specific:
This command is used to disconnect FSP and BPA nodes from HMC nodes, according to the connection information defined in ppc talbe in xCAT DB.
Note: If a CEC (FSP node represents) belongs to a frame with a BPA installed, this CEC cannot be disconnected individually. Instead, the whole frame (BPA node represents) should be disconnected.
For PPC (without HMC, using FSPAPI) specific:
It's used to disconnection FSP and BPA nodes from hardware server.
=head1 OPTIONS
=over 5
=item B<-h|--help>
Display usage message.
=item B<-V|--verbose>
Verbose output.
=item B<-T>
The tooltype is used to communicate to the FSP/BPA. The value could be lpar or fnm. The tooltype value lpar is for xCAT and fnm is for CNM.
=back
=head1 RETURN VALUE
0 The command completed successfully.
1 An error has occurred.
=head1 EXAMPLES
=over 3
=item 1.
To disconnect all FSP nodes in node group fsp from their HMC nodes:
rmhwconn fsp
=item 2.
To remove the connection for BPA node frame1:
rmhwconn frame1
=item 3.
To disconnect all FSP nodes in node group fsp from their related hardware serveri, using lpar tooltype:
rmhwconn fsp -T lpar
=back
=head1 FILES
$XCATROOT/bin/rmhwconn
(The XCATROOT environment variable is set when xCAT is installed. The
default value is "/opt/xcat".)
=head1 NOTES
This command is part of the xCAT software product.
=head1 SEE ALSO
L<lshwconn(1)|lshwconn.1>, L<mkhwconn(1)|mkhwconn.1>