=head1 NAME
B<xcatsetup> - Prime the xCAT database using naming conventions specified in a config file.
=head1 SYNOPSIS
B<xcatsetup> [B<-s|--stanzas> I<stanza-list>] [B<--yesreallydeletenodes>] I<cluster-config-file>
B<xcatsetup> [B<-?> | B<-h> | B<--help> | B<-v> | B<--version>]
=head1 DESCRIPTION
The B<xcatsetup> command reads the specified config file that contains general information about the cluster being set up,
and naming conventions and IP addresses that you want to use. It then defines the basic objects in the xCAT database
representing this cluster configuration. The B<xcatsetup> command prepares the database for the step of discovering
the hardware that is connected to the service and cluster networks. The typical steps of setting up a system p cluster are:
=over 3
=item *
Install the xCAT software on the management node
=item *
Create the cluster config file and run xcatsetup
=item *
Put hardware control passwords in the ppchcp or ppcdirect database table
=item *
Run makenetworks and makedhcp
=item *
Run the discovery commands (lsslp, mkhwconn, rspconfig) as described in the System P Hardware Management cookbook.
=item *
Configure and start services using makehosts, makedns, mkconserver.cf, etc.
=item *
Create the images that should be installed or booted on the nodes
=item *
Run nodeset and rpower/rnetboot to boot up the nodes.
=back
The B<xcatsetup> command is intended as a quick way to fill out the database for a cluster that has very regular
naming patterns. The only thing it does is fill in database attributes. If your cluster does not follow consistent
naming patterns, or has some other special configuration, you should define attribute values manually using L<mkdef(1)|mkdef.1>, instead of using
B<xcatsetup>. The cluster config file is meant to be an easy way to prime the database; it is not meant to be a
long living file that you update as the cluster changes. If you do want to run xcatsetup again at a later time,
because, for example, you added a lot of nodes, you should put the total list of nodes in the config file, not just
the new ones. This is because xcatsetup uses some regular expressions for groups (e.g. frame, cec, compute) that would
be calculated incorrectly if the config file told xcatsetup about only the new nodes.
Speaking of regular expressions, xcatsetup creates some pretty complicated regular expressions in the database.
These are useful because they keep most of the tables small, even for large clusters. But if you want to
tweak them, they may be hard to understand. If after running xcatsetup, you want to convert your database to
use individual rows for every node, you can do the following:
lsdef -z all >tmp.stanza
cat tmp.stanza | chdef -z
Many of the sections and attributes in the configuration file can be omitted, if you have a simple cluster, or if you want
to create just 1 or 2 of the object types at this time. See the section B<A Simpler Configuration File> for an example of this.
If you want to delete all of the nodes that xcatsetup created, and start over, use the B<--yesreallydeletenodes> option.
=head2 Restrictions
=over 3
=item *
The B<xcatsetup> command has only been implemented and tested for system p servers so far.
=back
=head2 Configuration File
The B<config file> is organized in stanza format and supports the keywords in the sample file below. Comment lines
begin with "#". Stanzas can be ommitted if you do not want to define that type of object.
The only hostname formats supported are those shown in this sample file, although you can change the base
text and the numbers. For example, hmc1-hmc3 could be changed to hwmgmt01-hwmgmt12.
The hostnames specified must sort correctly. I.e. use node01-node80, instead of node1-node80.
This sample configuration file is for a 2 building block cluster.
xcat-site:
domain = cluster.com
# currently only direct fsp control is supported
use-direct-fsp-control = 1
# ISR network topology. For example, one of the following: 128D, 64D, 32D, 16D, 8D, 4D, 2D, 1D
topology = 32D
# The nameservers in site table will be set with the value of master automatically.
xcat-service-lan:
# IP range used for DHCP. If you set the entry, the networks table will be filled
# automatically with this range and the dhcp interface will be set in the site table.
dhcp-dynamic-range = 50.0.0.0-50.0.0.200
xcat-hmcs:
hostname-range = hmc1-hmc2
starting-ip = 10.200.1.1
xcat-frames:
# these are the connections to the frames
hostname-range = frame[1-6]
num-frames-per-hmc = 3
# this lists which serial numbers go with which frame numbers
vpd-file = vpd2bb.stanza
# There are two rules of defining FSP/BPAs. The first defining the node's host name by increasing the last bit
# of IP address, while the second defining the node's name by varying the second bit and the third bit of IP.
# This assumes you have 2 service LANs: a primary service LAN 10.230.0.0/255.255.0.0 that all of the port 0's
# are connected to, and a backup service LAN 10.231.0.0/255.255.0.0 that all of the port 1's are connected to.
# bpa-a-0-starting-ip = 10.230.1.1
# bpa-b-0-starting-ip = 10.230.2.1
# bpa-a-1-starting-ip = 10.231.1.1
# bpa-b-1-starting-ip = 10.231.2.1
# This assumes you have 2 service LANs: a primary service LAN 40.x.y.z/255.0.0.0 that all of the port 0's
# are connected to, and a backup service LAN 41.x.y.z/255.0.0.0 that all of the port 1's are connected to.
# "x" is the frame number and "z" is the bpa/fsp id (1 for the first BPA/FSP in the Frame/CEC, 2 for the
# second BPA/FSP in the Frame/CEC). For BPAs "y" is always be 0 and for FSPs "y" is the cec id.
vlan-1 = 40
vlan-2 = 41
xcat-cecs:
# These are the connections to the CECs. Either form of hostname is supported.
#hostname-range = cec01-cec64
hostname-range = f[1-6]c[01-12]
# If you use the frame/cec hostname scheme above, but do not have a consistent
# number of cecs in each frame, xcat can delete the cecs that do not get
# supernode numbers assigned to them.
delete-unused-cecs = 1
# lists the HFI supernode numbers for each group of cecs in each frame
supernode-list = supernodelist2bb.txt
# If you do not want to specify the supernode-list at this time and you have a consistent
# number of cecs in each frame, you can instead just use this setting:
num-cecs-per-frame = 12
#fsp-a-0-starting-ip = 10.230.3.1
#fsp-b-0-starting-ip = 10.230.4.1
#fsp-a-1-starting-ip = 10.231.3.1
#fsp-b-1-starting-ip = 10.231.4.1
xcat-building-blocks:
num-frames-per-bb = 3
num-cecs-per-bb = 32
xcat-lpars:
num-lpars-per-cec = 8
# If you set these, then do not set the corresponding attributes in the other node stanzas below.
# Except you still need to set xcat-service-nodes:starting-ip (which is the ethernet adapter)
#hostname-range = f[1-6]c[01-12]p[1-8]
hostname-range = f[1-6]c[01-12]p[01,05,09,13,17,21,25,29]
starting-ip = 10.1.1.1
aliases = -hf0
# ml0 is for aix. For linux, use bond0 instead.
otherinterfaces = -hf1:11.1.1.1,-hf2:12.1.1.1,-hf3:13.1.1.1,-ml0:14.1.1.1
xcat-service-nodes:
num-service-nodes-per-bb = 2
# which cecs within the bldg block that the SNs are located in
cec-positions-in-bb = 1,32
# this is for the ethernet NIC on each SN
#hostname-range = sn1-sn4
starting-ip = 10.10.1.1
# this value is the same format as the hosts.otherinterfaces attribute except
# the IP addresses are starting IP addresses
#otherinterfaces = -hf0:10.10.1.1,-hf1:10.11.1.1,-hf2:10.12.1.1,-hf3:10.13.1.1,-ml0:10.14.1.1
xcat-storage-nodes:
num-storage-nodes-per-bb = 3
# which cecs within the bldg block that the storage nodes are located in
cec-positions-in-bb = 12,20,31
#hostname-range = stor1-stor6
#starting-ip = 10.20.1.1
#aliases = -hf0
#otherinterfaces = -hf1:10.21.1.1,-hf2:10.22.1.1,-hf3:10.23.1.1,-ml0:10.24.1.1
xcat-compute-nodes:
#hostname-range = n001-n502
#starting-ip = 10.30.1.1
#aliases = -hf0
# ml0 is for aix. For linux, use bond0 instead.
#otherinterfaces = -hf1:10.31.1.1,-hf2:10.32.1.1,-hf3:10.33.1.1,-ml0:10.34.1.1
=head2 VPD File for Frames
The B<vpd-file> specifies the following vpd table attributes for the frames: node,
serial, mtm, side. Use the same stanza format that accepted by the L<chdef(1)|chdef.1> command, as documented
in L<xcatstanzafile(5)|xcatstanzafile.5>. The purpose of this file is to enable xCAT to match up frames found
through L<lsslp(1)|lsslp.1> discovery with the database objects created by B<xcatsetup>. All of the frames
in the cluster must be specified.
Here is a sample file:
frame1:
objtype=node
serial=99200G1
mtm=9A00-100
frame2:
objtype=node
serial=99200D1
mtm=9A00-100
frame3:
objtype=node
serial=99200G1
mtm=9A00-100
frame4:
objtype=node
serial=99200D1
mtm=9A00-100
frame5:
objtype=node
serial=99200G1
mtm=9A00-100
frame6:
objtype=node
serial=99200D1
mtm=9A00-100
=head2 Supernode Numbers for CECs
The B<supernode-list> file lists what supernode numbers should be given to each CEC in each frame.
Here is a sample file:
frame1: 0, 1, 16
frame2: 17, 32
frame3: 33, 48, 49
frame4: 64 , 65, 80
frame5: 81, 96
frame6: 97(1), 112(1), 113(1), 37(1), 55, 71
The name before the colon is the node name of the frame. The numbers after the colon are the supernode numbers
to assign to the groups of CECs in that frame from bottom to top. Each supernode contains 4 CECs, unless it is immediately
followed by "(#)", in which case the number in parenthesis indicates how many CECs are in this supernode.
=head2 A Simpler Configuration File
This is an example of a simple cluster config file that just defines the frames and CECs for 2 frames, without specifying
VPD data or supernode numbers at this time.
xcat-site:
use-direct-fsp-control = 1
xcat-frames:
hostname-range = frame[1-2]
xcat-cecs:
#hostname-range = cec[01-24]
hostname-range = f[1-2]c[01-12]
num-cecs-per-frame = 12
xcat-lpars:
hostname-range = f[1-2]c[01-12]p[01,05,09,13,17,21,25,29]
=head2 Database Attributes Written
The following lists which database attributes are filled in as a result of each stanza. Note that depending on the values
in the stanza, some attributes might not be filled in.
=over 15
=item B<xcat-site>
site table: domain, nameservers, topology
=item B<xcat-hmcs>
site table: ea_primary_hmc, ea_backup_hmc
nodelist table: node, groups (all HMCs (hmc) ), hidden
hosts table: node, ip
ppc table: node, comments
nodetype table: node, nodetype
=item B<xcat-frames>
nodelist table: node, groups (all frames (frame) ), hidden
ppc table: node, id, hcp, nodetype, sfp
nodetype table: node, nodetype
nodehm table: node, mgt
vpd table: node, serial, mtm, side
=item B<xcat-bpas>
nodelist table: node, groups (bpa,all) , hidden
ppc table: node, id, hcp, nodetype, parent
nodetype table: node, nodetype
nodehm table: node, mgt
vpd table: node, serial, mtm, side
=item B<xcat-cecs>
nodelist table: node, groups (all CECs (cec), all CECs in a frame (<frame>cec) ), hidden
ppc table: node, supernode, hcp, id, parent
nodetype table: node, nodetype
nodehm table: node, mgt
nodegroup table: groupname, grouptype, members, wherevals (all nodes in a CEC (<cec>nodes) )
nodepos: rack, u
=item B<xcat-fsps>
nodelist table: node, groups (fsp,all), hidden
ppc table: node, id, hcp, nodetype, parent
nodetype table: node, nodetype
nodehm table: node, mgt
vpd table: node, serial, mtm, side
=item B<xcat-building-blocks>
site table: sharedtftp, sshbetweennodes(service)
ppc table: node, parent (for frame)
=item B<xcat-service-nodes>
nodelist table: node, groups (all service nodes (service), all service nodes in a BB (bb<num>service) )
hosts table: node, ip, hostnames, otherinterfaces
ppc table: node, id, hcp, parent
nodetype table: node, nodetype, arch
nodehm table: node, mgt, cons
noderes table: netboot
servicenode table: node, nameserver, dhcpserver, tftpserver, nfsserver, conserver, monserver, ftpserver, nimserver, ipforward
nodegroup table: groupname, grouptype, members, wherevals (all nodes under a service node (<servicenode>nodes) )
nodepos: rack, u
=item B<xcat-storage-nodes>
nodelist table: node, groups (all storage nodes (storage), all storage nodes in a BB (bb<num>storage) )
hosts table: node, ip, hostnames, otherinterfaces
ppc table: node, id, hcp, parent
nodetype table: node, nodetype, arch
nodehm table: node, mgt, cons
noderes table: netboot, xcatmaster, servicenode
nodepos: rack, u
=item B<xcat-compute-nodes>
nodelist table: node, groups (all compute nodes (compute) )
hosts table: node, ip, hostnames, otherinterfaces
ppc table: node, id, hcp, parent
nodetype table: node, nodetype, arch
nodehm table: node, mgt, cons
noderes table: netboot, xcatmaster, servicenode
nodepos: rack, u
=item B<ll-config>
postscripts: postscripts
=back
=head1 OPTIONS
=over 10
=item B<-s|--stanzas> I<stanza-list>
A comma-separated list of stanza names that B<xcatsetup> should process in the configuration file. If not specified, it will process
all the stanzas that start with 'xcat' and some other stanzas that give xCAT hints about how to set up the HPC products.
This option should only be specified if you have already run B<xcatsetup> earlier with the stanzas that occur before this in the
configuration file. Otherwise, objects will be created that refer back to other objects that do not exist in the database.
=item B<-v|--version>
Command Version.
=item B<-?|-h|--help>
Display usage message.
=item B<--yesreallydeletenodes>
Delete the nodes represented in the cluster config file, instead of creating them. This is useful if your first attempt with the cluster
config file wasn't quite right and you want to start over. But use this option with extreme caution, because it will potentially delete
a lot of nodes. If the only thing you have done so far in your database is add nodes by running B<xcatsetup>, then it is safe to use this
option to start over. If you have made other changes to your database, you should first back it up using L<dumpxCATdb(1)|dumpxCATdb.1> before
using this option.
=back
=head1 RETURN VALUE
0 The command completed successfully.
1 An error has occurred.
=head1 EXAMPLES
=over 3
=item 1.
Use the sample config.txt file at the beginning of this man page to create all the objects/nodes for a
2 building block cluster.
xcatsetup config.txt
The output:
Defining site attributes...
Defining HMCs...
Defining frames...
Defining CECs...
Defining building blocks...
Defining LPAR nodes...
=item 2.
Use the simpler config file shown earlier in this man page to create just the frame and cec objects:
xcatsetup config-simple.txt
The output:
Defining frames...
Defining CECs...
=back
=head1 FILES
/opt/xcat/sbin/xcatsetup
=head1 SEE ALSO
L<mkdef(1)|mkdef.1>, L<chdef(1)|chdef.1>, L<lsdef(1)|lsdef.1>, L<xcatstanzafile(5)|xcatstanzafile.5>, L<noderange(3)|noderange.3>, L<nodeadd(8)|nodeadd.8>