=head1 NAME
B<rpower> - remote power control of nodes
=head1 SYNOPSIS
B<rpower> I<noderange> [B<--nodeps>] [B<on>|B<onstandby>|B<off>|B<suspend>|B<stat>|B<state>|B<reset>|B<boot>] [B<-m> I<table.column>==I<expectedstatus> [B<-m> I<table.column>=~I<expectedstatus>]] [B<-t> I<timeout>] [B<-r> I<retrycount>]
B<rpower> [B<-h>|B<--help>|B<-v>|B<--version>]
=head2 PPC (with IVM or HMC) specific:
B<rpower> I<noderange> [B<--nodeps>] {B<of>}
=head2 PPC (with HMC) specific:
B<rpower> I<noderange> [B<onstandby>]
B<rpower> I<noderange> [B<softoff>]
=head2 Blade specific:
B<rpower> I<noderange> [B<cycle>|B<softoff>]
=head1 DESCRIPTION
B<rpower> controls the power for a single or range of nodes, via the out-of-band path.
=head1 OPTIONS
=over 4
=item B<on>
Turn power on.
=item B<onstandby>
Turn power on to standby state
=item B<softoff>
Attempt to request clean shutdown of OS (may not detect failures in completing command)
=item B<off>
Turn power off.
=item B<suspend>
Suspend the target nodes execution
=item B<stat>|B<state>
Print the current power state/status.
=item B<reset>
Send a hard reset.
=item B<boot>
If off, then power on.
If on, then hard reset.
This option is recommended over B<cycle>.
=item B<cycle>
Power off, then on.
=item B<of>
Boot the node to open firmware mode.
=item B<-m> I<table.column>==I<expectedstatus> B<-m> I<table.column>=~I<expectedstatus>
Use one or multiple B<-m> flags to specify the node attributes and the expected status for the node installation monitoring and automatic retry mechanism. The operators ==, !=, =~ and !~ are valid. This flag must be used with -t flag.
Note: if the "val" fields includes spaces or any other characters that will be parsed by shell, the "attr<oper-ator>val" needs to be quoted. If the operator is "!~", the "attr<operator>val" needs to be quoted using single quote.
=item B<--nodeps>
Do not use dependency table (default is to use dependency table). Valid only with B<on|off|boot|reset|cycle> for blade power method and B<on|off|reset|softoff> for hmc/fsp power method.
=item B<-r> I<retrycount>
specify the number of retries that the monitoring process will perform before declare the failure. The default value is 3. Setting the retrycount to 0 means only monitoring the os installation progress and will not re-initiate the installation if the node status has not been changed to the expected value after timeout. This flag must be used with -m flag.
=item B<-t> I<timeout>
Specify the the timeout, in minutes, to wait for the expectedstatus specified by -m flag. This is a required flag if the -m flag is specified.
Power off, then on.
=item B<-h>|B<--help>
Prints out a brief usage message.
=item B<-v>|B<--version>
Display the version number.
=back
=head1 EXAMPLES
=over 3
=item *
rpower node4,node5 stat
node4: on
node5: off
=item *
rpower node5 on
node5: on
=back
=head1 SEE ALSO
L<noderange(3)|noderange.3>, L<rcons(1)|rcons.1>, L<rinv(1)|rinv.1>, L<rvitals(1)|rvitals.1>, L<rscan(1)|rscan.1>