* Global variables
*/
var monitorTabs; // Monitor tabs
/**
* Set the monitor tab
*
* @param o
* Tab object
* @return Nothing
*/
function setMonitorTab(o) {
monitorTabs = o;
}
/**
* Get the monitor tab
*
* @return Tab object
*/
function getMonitorTab() {
return monitorTabs;
}
/**
* Load the monitor page
*/
function loadMonitorPage() {
// If the page is already loaded
if ($('#monitor_page').children().length) {
// Do not reload the monitor page
return;
}
// Create monitor tab
var tab = new Tab();
setMonitorTab(tab);
tab.init();
$('#content').append(tab.object());
var monitorForm = $('
');
monitorForm.append('Getting monitoring status ').append(createLoader());
tab.add('monitorTab', 'Monitor', monitorForm, false);
// Get monitoring status of each tool
$.ajax( {
url : 'lib/cmd.php',
dataType : 'json',
data : {
cmd : 'webrun',
tgt : '',
args : 'monls',
msg : ''
},
/**
* Load monitoring status
*
* @param data Data returned from HTTP request
*/
success : function(data){
// Initialize status for each tool
var statusHash = new Object();
statusHash['xcatmon'] = 'Off';
statusHash['rmcmon'] = 'Off';
statusHash['rmcevent'] = 'Off';
statusHash['gangliamon'] = 'Off';
if (data.rsp[0]) {
var tempArray = data.rsp[0].split(';');
var position = 0;
var name = '';
var status = '';
for ( var i in tempArray) {
position = tempArray[i].indexOf(':');
if (position == -1) {
continue;
}
name = tempArray[i].substr(0, position);
status = tempArray[i].substr(position + 1);
statusHash[name] = status;
}
}
// Create a status buttonset for each monitoring tool
var statusButtonHash = new Object();
for ( var name in statusHash) {
var statusButton = $('').css({
'width': '100px',
'text-align': 'center'
});
statusButtonHash[name] = statusButton;
// Set button to correct status
if (statusHash[name] == 'On') {
statusButton.append($(''));
statusButton.append($(''));
} else {
statusButton.append($(''));
statusButton.append($(''));
}
statusButton.find('label').css({
'margin': '0px',
'padding': '0px',
'font-size': '10px',
'width': 'auto'
});
statusButton.buttonset();
// Turn on or off monitoring tool when clicked
statusButton.find('input["' + name + '"]:radio').change(toggleMonitor);
}
var monTable = $('
');
monTable.append($('
Tool
Status
Description
'));
var monTableBody = $('');
monTable.append(monTableBody);
var xcatMon = $('
xCAT provides node status monitoring using fping on AIX and nmapon Linux. It also provides application status monitoring. The status and the appstatus columns of the nodelist table will be updated periodically with the latest status values for the nodes.
'));
monTableBody.append(xcatMon);
var rmcMon = $('
Resource Monitoring and Control (RMC) is a generalized framework for managing, monitoring and manipulating resources, such as physical or logical system entities. RMC is utilized as a communication mechanism for reporting service events to the Hardware Management Console (HMC).
'));
monTableBody.append(rmcMon);
var rmcEvent = $('
Ganglia is a scalable distributed monitoring system for high-performance computing systems such as clusters and Grids.
'));
monTableBody.append(gangliaMon);
// Do not word wrap
monTableBody.find('td:nth-child(1)').css('white-space', 'nowrap');
monTableBody.find('td:nth-child(3)').css({
'white-space': 'normal',
'text-align': 'left'
});
// Append info bar
$('#monitorTab div').empty().append(createInfoBar('Select a monitoring tool to use'));
$('#monitorTab .form').append(monTable);
// Open monitoring tool onclick
$('#monitorTab .form a').bind('click', function() {
loadMonitorTab($(this).attr('name'));
});
}
});
}
/**
* Load monitoring tool in a new tab
*
* @param name Name of monitoring tool
*/
function loadMonitorTab(name) {
// If the tab exist, then we only need to select it
var tab = getMonitorTab();
if ($("#" + name).length) {
tab.select(name);
return;
}
switch (name) {
case 'xcatmon':
tab.add(name, 'xCAT', '', true);
loadXcatMon();
break;
case 'rmcmon':
tab.add(name, 'RMC Monitor', '', true);
loadRmcMon();
break;
case 'gangliamon':
tab.add(name, 'Ganglia', '', true);
loadGangliaMon();
break;
case 'rmcevent':
tab.add(name, 'RMC Event', '', true);
loadRmcEvent();
break;
}
tab.select(name);
}
/**
* Load tab showing 'Under contruction'
*
* @param monitorName Name of monitoring tool
* @param tab Tab area
*/
function loadUnfinish(monitorName, tab) {
var unfinishPage = $('');
unfinishPage.append(createInfoBar('Not yet supported'));
tab.add(monitorName, 'Unfinished', unfinishPage, true);
}
/**
* Turn on or off monitoring tool
*
* @return Nothing
*/
function toggleMonitor() {
// Get the name of the monitoring tool
var name = $(this).attr('name');
// Get the status to toggle to, either on or off
var status = $(this).val();
// Start or stop monitoring plugin
var command = 'monstart';
if (status == 'Off') {
command = 'monstop' ;
}
// Start or stop monitoring on xCAT
$.ajax({
url : 'lib/cmd.php',
dataType : 'json',
data : {
cmd : command,
tgt : '',
args : name + '',
msg : ''
},
success : function(data) {
// Start or stop monitoring on remote nodes
$.ajax({
url : 'lib/cmd.php',
dataType : 'json',
data : {
cmd : command,
tgt : '',
args : name + ';-r',
msg : name + ' switched ' + status
},
success : updateMonStatus
});
}
});
}
/**
* Update the monitoring status on Monitor tab
*
* @param data Data returned from HTTP request
*/
function updateMonStatus(data) {
var rsp = data.rsp[data.rsp.length-1];
var msg = data.msg;
// Create appropriate info or warning bar
var bar = '';
if (rsp.indexOf('started') > -1 || rsp.indexOf('stopped') > -1) {
bar = createInfoBar(msg);
} else {
bar = createWarnBar('Failed to ' + msg + '. ' + rsp);
}
// Prepend info or warning bar to tab
bar.prependTo($('#monitorTab .form'));
bar.delay(4000).slideUp();
}