.\" Process this file with .\" groff -man -Tascii rinv.1 .\" .TH RINV 1 "Jan 2008" xCAT "xCAT" .SH NAME rinv \- remote hardware inventory .SH SYNOPSIS .B rinv [\fInoderange\fR] [\fIpci\fR|\fIconfig\fR|\fImodel\fR|\fIserial\fR|\fIasset\fR|\fIall\fR] .B rinv [\fI-h\fR|\fI--help\fR|\fI-v\fR|\fI--version\fR] .SH DESCRIPTION .B rinv retrieves hardware configuration information from the on-board Service Processor for a single or range of nodes and groups. .SH OPTIONS .IP \fBpci\fR Retrieves PCI bus information. .IP \fBconfig\fR Retrieves number of processors, speed, total memory, and DIMM locations. .IP \fBmodel\fR Retrieves model number. .IP \fBserial\fR Retrieves serial number. .IP \fBasset\fR Retrieves asset tag. Usually it's the MAC address of eth0. .IP \fBall\fR All of the above. .IP \fB-h\fR|\fB--help\fR Print help. .IP \fB-v\fR|\fB--version\fR Print version. .SH DIAGNOSTICS The following diagnostics may be issued on stdout/stderr: is not a node or a group .RS Node or group is not defined in .BR nodelist.tab (5). .RE function not supported .RS Node does not support remote power control or remote power control method not supported. .RE ping to $SPN failed .RS Where $SPN = the Service Processor Network defined in .BR mp.tab (5). PCI MPA adapter may not have power. Check Ethernet cable and IP. .RE telnet timeout .RS PCI MPA adapter may not have power. Check Ethernet cable and IP. .RE connection refused .RS Returned if telnet fails. PCI MPA may be in use or telnet interface is locked up. .BR mpareset (1) can be used to reboot the PCI MPA. .RE unknown asma $host .RS Returned if not in /etc/hosts or DNS. .RE name lookup failure .RS Returned if not in DNS. .RE node not on asma $SPN .RS Where $SPN = the SPN defined for that node in in .BR mp.tab (5). Use .BR mpncheck (1) $SPN to verify. Check cabling and try .BR mpareset (1). .RE remote session timeout .RS Communication with SPN was successful but communication with node failed. Check cabling. Try removing power from node, wait 10 seconds, then restore. .SH EXAMPLES \fIrinv node5 all\fR node5: Machine Type/Model 865431Z .br node5: Serial Number 23C5030 .br node5: Asset Tag 00:06:29:1F:01:1A .br node5: PCI Information .br node5: Bus VendID DevID RevID Description Slot Pass/Fail .br node5: 0 1166 0009 06 Host Bridge 0 PASS .br node5: 0 1166 0009 06 Host Bridge 0 PASS .br node5: 0 5333 8A22 04 VGA Compatible Controller 0 PASS .br node5: 0 8086 1229 08 Ethernet Controller 0 PASS .br node5: 0 8086 1229 08 Ethernet Controller 0 PASS .br node5: 0 1166 0200 50 ISA Bridge 0 PASS .br node5: 0 1166 0211 00 IDE Controller 0 PASS .br node5: 0 1166 0220 04 Universal Serial Bus 0 PASS .br node5: 1 9005 008F 02 SCSI Bus Controller 0 PASS .br node5: 1 14C1 8043 03 Unknown Device Type 2 PASS .br node5: Machine Configuration Info .br node5: Number of Processors: 2 .br node5: Processor Speed: 866 MHz .br node5: Total Memory: 512 MB .br node5: Memory DIMM locations: Slot(s) 3 4 .br .SH "FILES" .IX Header "FILES" /opt/xcat/bin/rinv .SH "NOTES" .IX Header "NOTES" This command is part of the xCAT software product.