Removed hfi option to all the xcat commands in man page

git-svn-id: https://svn.code.sf.net/p/xcat/code/xcat-core/trunk@9760 8638fb3e-16cb-4fca-ae20-7b5d299a9bcd
This commit is contained in:
wanghuaz 2011-06-08 03:05:16 +00:00
parent 709ec87249
commit c1f4fb991a
4 changed files with 3 additions and 34 deletions

View File

@ -12,7 +12,7 @@ B<getmacs> [B<-h>| B<--help> | B<-v>| B<--version>]
B<getmacs> I<noderange> [B<-F> I<filter>]
B<getmacs> I<noderange> [B<-V>| B<--verbose>] [B<-f>] [B<-d>] [B<--arp>] | [B<-D> [B<-S> I<server>] [B<-G> I<gateway>] [B<-C> I<client>] [B<--hfi>] [B<-o>]]
B<getmacs> I<noderange> [B<-V>| B<--verbose>] [B<-f>] [B<-d>] [B<--arp>] | [B<-D> [B<-S> I<server>] [B<-G> I<gateway>] [B<-C> I<client>] [B<-o>]]
=head2 blade specific:
@ -26,8 +26,6 @@ If no ping test performed, getmacs writes the first adapter MAC to the xCAT dat
For PPC (without HMC, using Direct FSP Management) specific:
If users run "B<getmacs> I<noderange>" directly for P7 IH LPARs, it will return the HIF MAC addresses which are owned by the LPARs. If run B<getmacs> with ping test by default, it will return the physical mac address. If run getmacs with ping test using B<--hfi>, it will return the HFI MAC address.
Note: If network adapters are physically assigned to LPARs, getmacs cannot read the MAC addresses unless perform ping test, since there is no HMC command to read them and getmacs has to login to open formware. And if the LPARs has never been activated before, getmacs need to be performed with the option "B<-D>" to get theirs MAC addresses.
=head1 OPTIONS
@ -64,10 +62,6 @@ B<-h>
Display usage message.
B<--hfi>
Read HFI MAC address. This option mush be used with [B<-D>] option to perform ping test.
B<-o>
Read MAC address when the lpar is in openfirmware state. This option mush be used with [B<-D>] option to perform ping test. Before use B<-o>, the lpar must be in openfirmware state.
@ -162,17 +156,6 @@ Output is similar to:
#Type Phys_Port_Loc MAC_Address Adapter Port_Group Phys_Port Logical_Port VLan VSwitch Curr_Conn_Speed
HFI N/A 02:00:02:00:00:04:|02:00:02:00:00:05:|02:00:02:00:00:06 N/A N/A N/A N/A N/A N/A N/A
7. To retrieve the HFI MAC address for P7 IH LPARl using Direct FSP Management ping test and display the result only, enter:
getmacs c250f07c07ap01 -d -D --hfi
Output is similar to:
c250f07c07ap01:
# Type Location Code MAC Address Full Path Name Ping Result
hfi-ent U78A9.001.0123456-P1 020004200004 /hfi-iohub@300000000000000/hfi-ethernet@0 unsuccessful physical
hfi-ent U78A9.001.0123456-P1 020004200004 /hfi-iohub@300000000000000/hfi-ethernet@1 unsuccessful physical
=head1 FILES
/opt/xcat/bin/getmacs

View File

@ -6,7 +6,7 @@ B<mkdsklsnode> - Use this xCAT command to define and initialize AIX/NIM diskless
B<mkdsklsnode [-h|--help ]>
B<mkdsklsnode [-V|--verbose] [-f|--force] [--hfi] [-n|--newname] [-i osimage_name] [-l location] [-p|--primarySN] [-b|--backupSN] noderange [attr=val [attr=val ...]]>
B<mkdsklsnode [-V|--verbose] [-f|--force] [-n|--newname] [-i osimage_name] [-l location] [-p|--primarySN] [-b|--backupSN] noderange [attr=val [attr=val ...]]>
=head1 DESCRIPTION
@ -94,10 +94,6 @@ Use the force option to reinitialize the NIM machines.
Display usage message.
=item B<--hfi>
Create a new NIM machine booting from HFI interfaces.
=item B<-i image_name>
The name of an existing xCAT osimage definition. If this information is not provided on the command line the code checks the node definition for the value of the "provmethod" attribute. If the "-i" value is provided on the command line then that value will be used to set the "provmethod" attribute of the node definitions.

View File

@ -4,7 +4,7 @@ B<rnetboot> - Cause the range of nodes to boot to network.
=head1 SYNOPSIS
B<rnetboot> [B<-V>|B<--verbose>] [B<-s> I<boot_device_order>] [B<-F>] [B<-f>] [B<--hfi>] I<noderange> [B<-m> I<table.column>==I<expectedstatus> [B<-m> I<table.col-umn>=~I<expectedstatus>]] [B<-t> I<timeout>] [B<-r> I<retrycount>]
B<rnetboot> [B<-V>|B<--verbose>] [B<-s> I<boot_device_order>] [B<-F>] [B<-f>] I<noderange> [B<-m> I<table.column>==I<expectedstatus> [B<-m> I<table.col-umn>=~I<expectedstatus>]] [B<-t> I<timeout>] [B<-r> I<retrycount>]
B<rnetboot> [B<-h>|B<--help>] [B<-v>|B<--version>]
@ -29,10 +29,6 @@ B<-f>
Force immediate shutdown of the partition.
B<--hfi>
Netboot the nodes from HFI devices.
B<-m>
Use one or multiple -m flags to specify the node attributes and the expected status for the node installation monitoring and automatic retry mechanism. The operators ==, !=, =~ and !~ are valid. This flag must be used with -t flag.

View File

@ -14,8 +14,6 @@ B<makedhcp> B<-d> I<noderange>
B<makedhcp> I<noderange> [B<-s> I<statements>]
B<makedhcp> I<noderange> B<--hfi>
B<makedhcp> [I<-h|--help>]
@ -67,10 +65,6 @@ Delete all node entries added by xCAT from the DHCP server configuration.
Delete all node entries, added by xCAT, in the noderange from the DHCP server configuration.
=item B<--hfi> I<noderange>
Add the specified nodes to the DHCP server configuration with HFI device type.
=item B<-h>
Display usage message.