=head1 NAME
B<rpower> - remote power control of nodes
=head1 SYNOPSIS
B<rpower> I<noderange> [B<--nodeps>] {B<on>|B<off>|B<stat>|B<state>|B<reset>|B<boot>|B<cycle>}
B<rpower> [B<-h>|B<--help>|B<-v>|B<--version>]
=head1 DESCRIPTION
B<rpower> controls the power for a single or range of nodes, via the out-of-band path.
=head1 OPTIONS
=over 4
=item B<on>
Turn power on.
=item B<off>
Turn power off.
=item B<stat>|B<state>
Print the current power state/status.
=item B<reset>
Send a hard reset.
=item B<boot>
If off, then power on.
If on, then hard reset.
This option is recommended over B<cycle>.
=item B<cycle>
Power off, then on.
=item B<--nodeps>
Do not use dependency table (default is to use dependency table). Valid only with on|off|boot|reset|cycle for blade power method.
=item B<-h>|B<--help>
Prints out a brief usage message.
=item B<-v>, B<--version>
Display the version number.
=back
=head1 EXAMPLES
=over 3
=item *
B<rpower> I<node4,node5 stat>
node4: on
node5: off
=item *
B<rpower> I<node5 on>
node5: on
=back
=head1 SEE ALSO
L<noderange(3)|noderange.3>, L<rcons(1)|rcons.1>, L<rinv(1)|rinv.1>, L<rvitals(1)|rvitals.1>, L<rscan(1)|rscan.1>