2009-09-21 06:33:27 +00:00
|
|
|
=head1 B<NAME>
|
|
|
|
|
|
|
|
B<renergy> - remote energy management tool
|
|
|
|
|
|
|
|
|
|
|
|
=head1 B<SYNOPSIS>
|
|
|
|
|
|
|
|
B<renergy> [-h | --help]
|
|
|
|
|
|
|
|
B<renergy> [-v | --version]
|
|
|
|
|
|
|
|
B<renergy> noderange [-V] {all | {[savingstatus]
|
|
|
|
[cappingstatus] [cappingmaxmin] [cappingvalue]
|
|
|
|
[cappingsoftmin] [averageAC] [averageDC]
|
|
|
|
[ambienttemp] [exhausttemp] [CPUspeed]}}
|
|
|
|
|
|
|
|
B<renergy> noderange [-V] {{savingstatus}={on | off}
|
|
|
|
| {cappingstatus}={on | off} | {cappingwatt}=watt
|
|
|
|
| {cappingperc}=percentage}
|
|
|
|
|
|
|
|
=head1 B<DESCRIPTION>
|
|
|
|
|
|
|
|
This renergy command can be used to manage the energy attributes of
|
|
|
|
a machine. Presently, it only supports IBM POWER6 rack-mounted servers.
|
|
|
|
Note: The keyword 'server' in this document is identical to
|
|
|
|
'rack-mounted server'.
|
|
|
|
|
2009-09-21 11:30:05 +00:00
|
|
|
The parameter 'noderange' can be a list of node names (CEC's name).
|
|
|
|
Note: Lpar name is not acceptable.
|
2009-09-21 06:33:27 +00:00
|
|
|
|
2009-09-21 11:30:05 +00:00
|
|
|
B<renergy> command can accept multiple attributes to query. If only
|
2009-09-21 06:33:27 +00:00
|
|
|
keywords list is specified, without the '=', it displays the current
|
|
|
|
value.
|
2009-09-21 11:30:05 +00:00
|
|
|
B<energy> command can only set one attribute once running.
|
2009-09-21 06:33:27 +00:00
|
|
|
|
2009-09-21 11:30:05 +00:00
|
|
|
For the attributes that are not supported by certain server, the return
|
2009-09-21 06:33:27 +00:00
|
|
|
value will be 'na'.
|
|
|
|
|
|
|
|
Prerequisite:
|
2009-09-21 11:30:05 +00:00
|
|
|
Before running the B<energy> command, a prerequisite package
|
|
|
|
B<xCAT-cimclient> needs to be downloaded from IBM web site and installed.
|
2009-09-21 06:33:27 +00:00
|
|
|
Note:
|
|
|
|
Each query operation for attribute CPUspeed, averageAC or averageDC
|
2009-09-21 11:30:05 +00:00
|
|
|
costs about 30 seconds to complete. Query for the others attributes
|
2009-09-21 06:33:27 +00:00
|
|
|
will get response immediately.
|
|
|
|
|
|
|
|
|
2009-09-27 08:00:43 +00:00
|
|
|
Only following specific hardware types are supported by B<renergy> command:
|
2009-09-21 06:33:27 +00:00
|
|
|
|
2009-09-27 08:00:43 +00:00
|
|
|
8203-E4A, 8204-E8A
|
2009-09-21 06:33:27 +00:00
|
|
|
Supports attributes: all
|
|
|
|
|
2009-09-27 08:00:43 +00:00
|
|
|
9125-F2A
|
2009-09-21 06:33:27 +00:00
|
|
|
Supports attributes: savingstatus,CPUspeed,ambienttemp,
|
|
|
|
exhausttemp,averageAC
|
|
|
|
|
|
|
|
|
|
|
|
=head1 B<OPTIONS>
|
|
|
|
|
|
|
|
-h | --help
|
|
|
|
Display the usage message.
|
|
|
|
|
|
|
|
-v | --version
|
|
|
|
Display the version information.
|
|
|
|
|
|
|
|
-V
|
2009-09-21 11:30:05 +00:00
|
|
|
Verbose output.
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
|
|
|
|
all
|
|
|
|
Query all of the energy attributes.
|
|
|
|
|
|
|
|
savingstatus
|
|
|
|
Query the Power Saving status. The result should be
|
|
|
|
'on' or 'off'.
|
|
|
|
Note: To support the power saving attribute, POWER6
|
|
|
|
processors should greater than or equal to 4.0 GHz.
|
|
|
|
|
|
|
|
savingstatus={on | off}
|
|
|
|
Set the Power Saving status. The value must be 'on'
|
|
|
|
or 'off'.
|
|
|
|
Note: The setting value needs about 2 minutes to take
|
|
|
|
effect.
|
|
|
|
|
|
|
|
cappingstatus
|
|
|
|
Query the Power Capping status. The result should be
|
2009-09-21 11:30:05 +00:00
|
|
|
'on' or 'off'.
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
cappingstatus={on | off}
|
|
|
|
Set the Power Capping status. The value must be 'on'
|
|
|
|
or 'off'.
|
|
|
|
|
|
|
|
cappingwatt=watt
|
|
|
|
Set the Power Capping value base on the watt unit.
|
|
|
|
If the 'watt' > maximum of cappingmaxmin or 'watt'
|
2009-09-21 11:30:05 +00:00
|
|
|
< minimum of cappingmaxmim, the setting operation
|
2009-09-21 06:33:27 +00:00
|
|
|
will fail.
|
|
|
|
|
|
|
|
cappingperc=percentage
|
|
|
|
Set the Power Capping value base on the percentage of
|
2009-09-21 11:30:05 +00:00
|
|
|
the max-min of capping value.
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
cappingmaxmin
|
|
|
|
Query the maximum and minimum of Power Capping value
|
2009-09-21 11:30:05 +00:00
|
|
|
that can be set for a CEC. (Unit is watt)
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
cappingvalue
|
|
|
|
Query the current Power Capping value. (Unit is watt)
|
|
|
|
|
|
|
|
cappingsoftmin
|
|
|
|
Query the minimum value that can be assigned to Pcap
|
|
|
|
without guaranteed enforceability. (Unit is watt)
|
|
|
|
|
|
|
|
averageAC
|
|
|
|
Query the average power consumed (Input). (Unit is watt)
|
2009-09-21 11:30:05 +00:00
|
|
|
Note: For 9125 and 9119 server, the value of attribute
|
2009-09-21 06:33:27 +00:00
|
|
|
averageAC is the aggregate for all of the servers in the
|
|
|
|
rack.
|
|
|
|
|
|
|
|
averageDC
|
|
|
|
Query the average power consumed (Output). (Unit is
|
|
|
|
watt)
|
|
|
|
|
|
|
|
ambienttemp
|
2009-09-21 11:30:05 +00:00
|
|
|
Query the current ambient temperature. (Unit is centigrade)
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
exhausttemp
|
2009-09-21 11:30:05 +00:00
|
|
|
Query the current exhaust temperature. (Unit is centigrade)
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
CPUspeed
|
|
|
|
Query the effective CPU speed. (Unit is MHz)
|
|
|
|
|
|
|
|
|
|
|
|
=head1 B<RETURN VALUE>
|
|
|
|
|
|
|
|
0 The command completed successfully.
|
|
|
|
|
|
|
|
1 An error has occurred.
|
|
|
|
|
|
|
|
|
|
|
|
=head1 B<EXAMPLES>
|
|
|
|
|
|
|
|
1. Query all the attributes which CEC1,CEC2 supported
|
|
|
|
B<renergy> CEC1,CEC2 all
|
|
|
|
|
|
|
|
The output of the query operation:
|
|
|
|
CEC1: savingstatus: on
|
|
|
|
CEC1: cappingstatus: on
|
|
|
|
CEC1: cappingmin: 782 W
|
|
|
|
CEC1: cappingmax: 850 W
|
|
|
|
CEC1: cappingvalue: 816 W
|
|
|
|
CEC1: cappingsoftmin: 200 W
|
|
|
|
CEC1: averageAC: 430 W
|
|
|
|
CEC1: averageDC: 364 W
|
|
|
|
CEC1: ambienttemp: 25 C
|
|
|
|
CEC1: exhausttemp: 32 C
|
|
|
|
CEC1: CPUspeed: 3621 MHz
|
|
|
|
CEC2: savingstatus: off
|
|
|
|
CEC2: cappingstatus: off
|
|
|
|
CEC2: cappingmin: na
|
|
|
|
CEC2: cappingmax: na
|
|
|
|
CEC2: cappingvalue: na
|
|
|
|
CEC2: cappingsoftmin: na
|
|
|
|
CEC2: averageAC: na
|
|
|
|
CEC2: averageDC: na
|
|
|
|
CEC2: ambienttemp: na
|
|
|
|
CEC2: exhausttemp: na
|
|
|
|
CEC2: CPUspeed: na
|
|
|
|
|
|
|
|
2. Query the attributes savingstatus, cappingstatus
|
|
|
|
and CPUspeed of server CEC1
|
|
|
|
B<renergy> CEC1 savingstatus,cappingstatus,CPUspeed
|
|
|
|
|
|
|
|
The output of the query operation:
|
|
|
|
CEC1: savingstatus: off
|
|
|
|
CEC1: cappingstatus: on
|
|
|
|
CEC1: CPUspeed: 3621 MHz
|
|
|
|
|
|
|
|
3. Turn on the Power saving function of CEC1
|
|
|
|
B<renergy> CEC1 savingstatus=on
|
|
|
|
|
|
|
|
The output of the setting operation:
|
|
|
|
CEC1: Set savingstatus succeeded.
|
|
|
|
CEC1: This setting may need some minutes to take effect.
|
|
|
|
|
|
|
|
4. Set the Power Capping value base on the percentage of the
|
|
|
|
max-min capping value
|
2009-09-21 11:30:05 +00:00
|
|
|
B<renergy> CEC1 cappingperc=50
|
2009-09-21 06:33:27 +00:00
|
|
|
|
|
|
|
If the maximum capping value of the CEC1 is 850w, and the
|
|
|
|
minimum capping value of the CEC1 is 782w, the Power Capping
|
|
|
|
value will be set as ((850-782)*50% + 782) = 816w.
|
|
|
|
|
|
|
|
The output of the setting operation:
|
|
|
|
CEC1: Set cappingperc succeeded.
|
|
|
|
CEC1: cappingvalue: 816
|
|
|
|
|
|
|
|
|
|
|
|
=head1 B<FILES>
|
|
|
|
|
|
|
|
/opt/xcat/bin/renergy
|
|
|
|
|
|
|
|
|