| This describes the interface for the ADT7475 driver:
 | |
| 
 | |
| (there are 4 fans, numbered fan1 to fan4):
 | |
| 
 | |
| fanX_input		Read the current speed of the fan (in RPMs)
 | |
| fanX_min		Read/write the minimum speed of the fan.  Dropping
 | |
| 			below this sets an alarm.
 | |
| 
 | |
| (there are three PWMs, numbered pwm1 to pwm3):
 | |
| 
 | |
| pwmX			Read/write the current duty cycle of the PWM.  Writes
 | |
| 			only have effect when auto mode is turned off (see
 | |
| 			below).  Range is 0 - 255.
 | |
| 
 | |
| pwmX_enable		Fan speed control method:
 | |
| 
 | |
| 			0 - No control (fan at full speed)
 | |
| 			1 - Manual fan speed control (using pwm[1-*])
 | |
| 			2 - Automatic fan speed control
 | |
| 
 | |
| pwmX_auto_channels_temp	Select which channels affect this PWM
 | |
| 
 | |
| 			1 - TEMP1 controls PWM
 | |
| 			2 - TEMP2 controls PWM
 | |
| 			4 - TEMP3 controls PWM
 | |
| 			6 - TEMP2 and TEMP3 control PWM
 | |
| 			7 - All three inputs control PWM
 | |
| 
 | |
| pwmX_freq		Read/write the PWM frequency in Hz. The number
 | |
| 			should be one of the following:
 | |
| 
 | |
| 			11 Hz
 | |
| 			14 Hz
 | |
| 			22 Hz
 | |
| 			29 Hz
 | |
| 			35 Hz
 | |
| 			44 Hz
 | |
| 			58 Hz
 | |
| 			88 Hz
 | |
| 
 | |
| pwmX_auto_point1_pwm	Read/write the minimum PWM duty cycle in automatic mode
 | |
| 
 | |
| pwmX_auto_point2_pwm	Read/write the maximum PWM duty cycle in automatic mode
 | |
| 
 | |
| (there are three temperature settings numbered temp1 to temp3):
 | |
| 
 | |
| tempX_input		Read the current temperature.  The value is in milli
 | |
| 			degrees of Celsius.
 | |
| 
 | |
| tempX_max		Read/write the upper temperature limit - exceeding this
 | |
| 			will cause an alarm.
 | |
| 
 | |
| tempX_min		Read/write the lower temperature limit - exceeding this
 | |
| 			will cause an alarm.
 | |
| 
 | |
| tempX_offset		Read/write the temperature adjustment offset
 | |
| 
 | |
| tempX_crit		Read/write the THERM limit for remote1.
 | |
| 
 | |
| tempX_crit_hyst		Set the temperature value below crit where the
 | |
| 			fans will stay on - this helps drive the temperature
 | |
| 			low enough so it doesn't stay near the edge and
 | |
| 			cause THERM to keep tripping.
 | |
| 
 | |
| tempX_auto_point1_temp	Read/write the minimum temperature where the fans will
 | |
| 			turn on in automatic mode.
 | |
| 
 | |
| tempX_auto_point2_temp	Read/write the maximum temperature over which the fans
 | |
| 			will run in automatic mode.  tempX_auto_point1_temp
 | |
| 			and tempX_auto_point2_temp together define the
 | |
| 			range of automatic control.
 | |
| 
 | |
| tempX_alarm		Read a 1 if the max/min alarm is set
 | |
| tempX_fault		Read a 1 if either temp1 or temp3 diode has a fault
 | |
| 
 | |
| (There are two voltage settings, in1 and in2):
 | |
| 
 | |
| inX_input		Read the current voltage on VCC.  Value is in
 | |
| 			millivolts.
 | |
| 
 | |
| inX_min			read/write the minimum voltage limit.
 | |
| 			Dropping below this causes an alarm.
 | |
| 
 | |
| inX_max			read/write the maximum voltage limit.
 | |
| 			Exceeding this causes an alarm.
 | |
| 
 | |
| inX_alarm		Read a 1 if the max/min alarm is set.
 |